The functioning of oxygen concentrators in resource-limited settings: a situation assessment in two countries

被引:24
作者
La Vincente, S. F. [1 ]
Peel, D. [2 ]
Carai, S. [3 ]
Weber, M. W. [4 ]
Enarson, P. [5 ]
Maganga, E. [6 ]
Soyolgerel, G. [7 ]
Duke, T. [1 ,8 ]
机构
[1] Univ Melbourne, Murdoch Childrens Res Inst, Royal Childrens Hosp, Ctr Int Child Hlth,Dept Paediat, Melbourne, Vic, Australia
[2] Ashdown Consultants, Hartfield, E Sussex, England
[3] WHO, Dept Child & Adolescent Hlth & Dev, CH-1211 Geneva, Switzerland
[4] WHO, Country Off Indonesia, Jakarta, Indonesia
[5] Int Union TB & Lung Dis, Child Lung Hlth Div, Paris, France
[6] Minist Hlth, Community Hlth Sci Unit, Lilongwe, Malawi
[7] Minist Hlth, Ulaanbaatar, Mongolia
[8] Univ Papua New Guinea, Sch Med & Hlth Sci, Port Moresby, Papua N Guinea
关键词
oxygen concentrators; child health; acute respiratory infection; hypoxaemia; hospital care; SEVERE PNEUMONIA; HYPOXEMIA; CHILDREN; HOSPITALS; EPIDEMIOLOGY;
D O I
10.5588/ijtld.10.0544
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
SETTING: The paediatric wards of hospitals in Malawi and Mongolia. OBJECTIVE: To describe oxygen concentrator functioning in two countries with widespread, long-term use of concentrators as a primary source of oxygen for treating children. DESIGN: A systematic assessment of concentrators in the paediatric wards of 15 hospitals in Malawi and nine hospitals in Mongolia. RESULTS: Oxygen concentrators had been installed for a median of 48 months (interquartile range [IQR] 6-60) and 36 months (IQR 12-96), respectively, prior to the evaluation in Malawi and Mongolia. Concentrators were the primary source of oxygen. Three quarters of the concentrators assessed in Malawi (28/36) and half those assessed in Mongolia (13/25) were functional. Concentrators were found to remain functional with up to 30000 h of use. However, several concentrators were functioning very poorly despite limited use. Concentrators from a number of different manufacturers were evaluated, and there was marked variation in performance between brands. Inadequate resources for maintenance were reported in both countries. CONCLUSION: Years after installation of oxygen concentrators, many machines were still functioning, indicating that widespread use can be sustained in resource-limited settings. However, concentrator performance varied substantially. Procurement of high-quality and appropriate equipment is critical, and resources should be made available for ongoing maintenance.
引用
收藏
页码:693 / 699
页数:7
相关论文
共 19 条
[1]   Field trial of oxygen concentrators in upper Egypt [J].
Dobson, M ;
Peel, D ;
Khallaf, N .
LANCET, 1996, 347 (9015) :1597-1599
[2]   OXYGEN CONCENTRATORS OFFER COST SAVINGS FOR DEVELOPING-COUNTRIES - A STUDY BASED ON PAPUA-NEW-GUINEA [J].
DOBSON, MB .
ANAESTHESIA, 1991, 46 (03) :217-219
[3]  
DOBSON MB, 1999, UPDATE ANAESTHESIA, V10, P1
[4]  
Duke T, 2001, INT J TUBERC LUNG D, V5, P511
[5]   Improved oxygen systems for childhood pneumonia: a multihospital effectiveness study in Papua New Guinea [J].
Duke, Trevor ;
Wandi, Francis ;
Jonathan, Merilyn ;
Matai, Sens ;
Kaupa, Magdalene ;
Saavu, Martin ;
Subhi, Rami ;
Peel, David .
LANCET, 2008, 372 (9646) :1328-1333
[6]   Implementation of an oxygen concentrator system in district hospital paediatric wards throughout Malawi [J].
Enarson, Penny ;
La Vincente, Sophie ;
Gie, Robert ;
Maganga, Ellubey ;
Chokani, Codewell .
BULLETIN OF THE WORLD HEALTH ORGANIZATION, 2008, 86 (05) :344-348
[7]   Assessment of inpatient paediatric care in first referral level hospitals in 13 districts in Kenya [J].
English, M ;
Esamai, F ;
Wasunna, A ;
Were, F ;
Ogutu, B ;
Wamae, A ;
Snow, RW ;
Peshu, N .
LANCET, 2004, 363 (9425) :1948-1953
[8]  
Hill SE, 2009, INT J TUBERC LUNG D, V13, P587
[9]   Beyond good intentions: lessons on equipment donation from an African hospital [J].
Howie, Stephen Rc ;
Hill, Sarah E. ;
Peel, David ;
Sanneh, Momodou ;
Njie, Malick ;
Hill, Philip C. ;
Mulholland, Kim ;
Aclegbola, Richard A. .
BULLETIN OF THE WORLD HEALTH ORGANIZATION, 2008, 86 (01) :52-56
[10]  
Lozano JM, 2001, INT J TUBERC LUNG D, V5, P496