A Systematic Review of the Tensile Biomechanical Properties of the Neonatal Brachial Plexus

被引:7
作者
Orozco, Virginia [1 ]
Magee, Rachel [1 ]
Balasubramanian, Sriram [1 ]
Singh, Anita [2 ]
机构
[1] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, 3140 Market St,BOSSONE 718, Philadelphia, PA 19104 USA
[2] Widener Univ, Dept Biomed Engn, One Univ Pl, Chester, PA 19013 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2021年 / 143卷 / 11期
基金
美国国家科学基金会;
关键词
PERIPHERAL-NERVES; SHOULDER DYSTOCIA; MECHANICAL-PROPERTIES; HUMAN ULNAR; IN-VITRO; PALSY; STRAIN; STRESS; CONDUCTION; INJURY;
D O I
10.1115/1.4051399
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Brachial plexus (BP) birth injury has a reported incidence of 1 to 4 per 1000 live births. During complicated deliveries, neonatal, maternal, and other birth-related factors can cause over-stretching or avulsion of the neonatal brachial plexus leading to injury. Understanding biomechanical responses of the neonate brachial plexus when subjected to stretch can offer insight into the injury outcomes while guiding the development of preventative maneuvers that can help reduce the occurrence of neonatal brachial plexus injuries. This review article aims to offer a comprehensive overview of existing literature reporting biomechanical responses of the brachial plexus, in both adults and neonates, when subjected to stretch. Despite the discrepancies in the reported biomechanical properties of the brachial plexus, available studies confirm the loading rate and loading direction dependency of the brachial plexus tissue. Future studies, possibly in vivo, that utilize clinically relevant neonatal large animal models can provide translational failure values of the biomechanical parameters for the neonatal brachial plexus when subjected to stretch.
引用
收藏
页数:11
相关论文
共 55 条
[1]   Brachial plexus birth palsy: Management during the first year of life [J].
Abid, A. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (01) :S125-S132
[2]   Current Concepts: Neonatal Brachial Plexus Palsy [J].
Abzug, Joshua M. ;
Kozin, Scott H. .
ORTHOPEDICS, 2010, 33 (06) :430-435
[3]  
Addas Bassam M, 2010, Neurosciences (Riyadh), V15, P136
[4]   NARAKAS CLASSIFICATION OF OBSTETRIC BRACHIAL PLEXUS PALSY REVISITED [J].
Al-Qattan, M. M. ;
El-Sayed, A. A. F. ;
Al-Zahrani, A. Y. ;
Al-Mutairi, S. A. ;
Al-Harbi, M. S. ;
Al-Mutairi, A. M. ;
Al-Kahtani, F. S. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (06) :788-791
[5]   Are there differences in mechanical fetal response between routine and shoulder dystocia deliveries? [J].
Allen, R ;
Cha, S ;
Kranker, L ;
Johnson, T ;
Gurewitsch, E .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2005, 193 (06) :S38-S38
[6]  
ALLEN R, 1991, OBSTET GYNECOL, V77, P352
[7]  
Andersen John, 2006, Paediatr Child Health, V11, P93
[8]   Neonatal Organ and Tissue Donation for Research: Options Following Death by Natural Causes [J].
Anderson, Martha ;
Youngner, Stuart ;
Smith, Regina Dunne ;
Nandyal, Raja R. ;
Orlowski, Jeffrey P. ;
Hill, B. Jessie ;
Barsman, Sarah Gutin .
CELL AND TISSUE BANKING, 2020, 21 (02) :289-302
[9]  
[Anonymous], 1970, Strength of Biological Materials
[10]   Towards viscoelastic characterisation of the human ulnar nerve: An early assessment using embalmed cadavers [J].
Barberio, Carla G. ;
Chaudhry, Tahseen ;
Power, Dominic M. ;
Tan, Simon ;
Lawlesse, Bernard M. ;
Espino, Daniel M. ;
Wilton, Joanne C. .
MEDICAL ENGINEERING & PHYSICS, 2019, 64 :15-22