Test beam results of CMS quartz fibre calorimeter prototype and simulation of response to high energy hadron jets

被引:4
作者
Akchurin, N
Ayan, S
Bencze, GL
Chikin, K
Cohn, H
Doulas, S
Dumanoglu, I
Eskut, E
Fenyvesi, A
Ferrando, A
Fouz, MC
Gavrilov, V
Gershtein, Y
Hajdu, C
Iosifidis, J
Josa, MI
Khan, A
Kim, SB
Kolosov, V [1 ]
Kuleshov, S
Langland, J
Litvinsev, D
Merlo, JP
Molnar, J
Nikitin, A
Onel, Y
Onengut, G
Osborne, D
Ozdes-Kosa, N
Penzo, A
Pesen, E
Podrasky, V
Rosowsky, A
Salicio, JM
Stolin, V
Sulak, L
Sullivan, J
Ulyanov, A
Umashev, A
Uzunian, S
Vesztergombi, G
Winn, D
Winsor, R
Zalan, P
Zeyrek, M
机构
[1] ITEP, Moscow, Russia
[2] Univ Iowa, Iowa City, IA 52242 USA
[3] Middle E Tech Univ, TR-06531 Ankara, Turkey
[4] KFKI RMKI, Budapest, Hungary
[5] NPI Moscow State Univ, Moscow, Russia
[6] Oak Ridge Natl Lab, Oak Ridge, TN USA
[7] Boston Univ, Boston, MA 02215 USA
[8] Cucurova Univ, Adana, Turkey
[9] ATOMKI, Debrecen, Hungary
[10] CIEMAT, E-28040 Madrid, Spain
[11] Fairfield Univ, Fairfield, CT 06430 USA
[12] Univ Trieste, I-34127 Trieste, Italy
[13] Ist Nazl Fis Nucl, Trieste, Italy
基金
匈牙利科学研究基金会;
关键词
D O I
10.1016/S0168-9002(97)01328-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
CMS very forward calorimeter is based on a quartz fibre technology. The calorimeter prototype composed of two longitudinal segments was tested at CERN in 1996, We present the test beam data analysis of this prototype. It was shown that the mean values of responses for pions and electrons of the same energy could be equalised using the appropriate ratio of calibration constants for longitudinal segments. The beam test data were used to simulate the calorimeter response to hadron jets. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:593 / 597
页数:5
相关论文
共 7 条
  • [1] Beam test results from a fine-sampling quartz fiber calorimeter for electron, photon and hadron detection
    Akchurin, N
    Ayan, S
    Bencze, GL
    Chikin, K
    Cohn, H
    Doulas, S
    Dumanoglu, I
    Eskut, E
    Fenyvesi, A
    Ferrando, A
    Fouz, MC
    Ganel, O
    Gavrilov, V
    Gershtein, Y
    Hajdu, C
    Iosifidis, J
    Josa, MI
    Khan, A
    Kim, SB
    Kolosov, V
    Kuleshov, S
    Langland, J
    Litvintsev, D
    Merlo, JP
    Molnar, J
    Nikitin, A
    Onel, Y
    Onengut, G
    Osborne, D
    OzdesKoca, N
    Penzo, A
    Pesen, E
    Podrasky, V
    Rosowsky, A
    Salico, JM
    Sanzeni, C
    Sever, R
    Silvestri, H
    Stolin, V
    Sulak, L
    Sullivan, J
    Ulyanov, A
    Uzunian, S
    Vesztergombi, G
    Wigmans, R
    Winn, D
    Winsor, R
    Yumashev, A
    Zalan, P
    Zeyrek, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 399 (2-3) : 202 - 226
  • [2] QUARTZ FIBER CALORIMETRY - MONTE-CARLO SIMULATION
    ANZIVINO, G
    CHUMAROVSKY, Y
    CONTIN, A
    DANILOV, M
    DELLACASA, G
    DESALVO, R
    GAVRILOV, V
    GOLUTVIN, A
    GORODETZKY, P
    HELLEBOID, JM
    ISAEV, V
    JOHNSON, KF
    JUILLOT, P
    KULESHOV, S
    LAZIC, D
    LITVINSEV, D
    LUNDIN, M
    MARINO, M
    MUSSO, A
    RATNIKOV, F
    RUSINOV, V
    STOLIN, V
    VINOGRADOV, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 357 (2-3) : 380 - 385
  • [3] *CMS COLL, 1994, 9439 CERN LHCC CMS C
  • [4] *CMS COLL, 1997, 9731 CERN LHCC CMS C
  • [5] CONTIN A, 1994, DRDC944 CERN
  • [6] GAVRILOV V, TN94324 CMS
  • [7] GORODETZKY P, 1995, NUCL INSTRUM METH A, V361, P1