Analytical formulae for borehole scintillation detectors efficiency calibration

被引:14
作者
Abbas, Mahmoud I. [1 ]
机构
[1] Univ Alexandria, Dept Phys, Fac Sci, Alexandria 21511, Egypt
关键词
Gamma spectrometry; Borehole scintillation detectors; Efficiency calibration; ENERGY PEAK EFFICIENCY; GAMMA-RAY DETECTORS; COINCIDENCE CORRECTIONS; RADIOACTIVE PARTICLES; PHOTOPEAK EFFICIENCY; MATHEMATICAL-METHOD; EXTENDED SOURCES; BGO DETECTOR; SPECTROMETER; SPECTRA;
D O I
10.1016/j.nima.2010.06.241
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The borehole scintillation detectors (with central borehole) are useful for the identification and quantification of unknown gamma-ray emitting radionuclides in geological and environmental samples due to the near 4 pi solid angle that can be obtained with them. In addition, the 4 pi gamma-ray-counting is a well-established method for direct activity measurements, and is especially suited for radionuclides with complex gamma-ray spectra. A straightforward theoretical approach was carried out to calculate the efficiencies (total, epsilon(T) and geometrical. epsilon(g)) of borehole scintillation detectors. The approach depends on the accurate calculation of two important factors: the path length, d, the photon traverses within the active volume of a gamma detector, and the geometrical solid angle, Omega, subtended by the source to the detector at the point of entrance. These two factors are theoretically derived through straightforward analytical formulae. Furthermore, the attenuation of photons by the source container and the detector housing materials is also treated by calculating the photon path length through these materials. The comparisons with the experimental and Monte Carlo method works reported in the literature indicate that the present approach is useful in the efficiency calibration of such complicated gamma-ray spectrometer. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:171 / 175
页数:5
相关论文
共 50 条
  • [41] Calibration of a Shower Lead-Scintillation Spectrometer by Cosmic Radiation
    Alekseev, V. I.
    Baskov, V. A.
    Dronov, V. A.
    L'vov, A. I.
    Koltsov, A. V.
    Krechetov, Yu. F.
    Polyansky, V. V.
    Sidorin, S. S.
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2020, 47 (09) : 262 - 266
  • [42] Characteristics of scintillation detectors based on inorganic scintillators and SiPM light readout
    Szczesniak, T.
    Grodzicka, M.
    Moszynski, M.
    Szawlowski, M.
    Wolski, D.
    Baszak, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 91 - 93
  • [43] A revision of energy and resolution calibration method of Ge detectors
    Hurtado, S.
    Garcia-Leon, M.
    Garcia-Tenorio, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 564 (01) : 295 - 299
  • [44] Spectral calibration and modeling of the NuSTAR CdZnTe pixel detectors
    Kitaguchi, Takao
    Grefenstette, Brian W.
    Harrison, Fiona A.
    Miyasaka, Hiromasa
    Bhalerao, Varun B.
    Cook, Walter R., III
    Mao, Peter H.
    Rana, Vikram R.
    Boggs, Steven E.
    Zoglauer, Andreas C.
    UV, X-RAY, AND GAMMA-RAY SPACE INSTRUMENTATION FOR ASTRONOMY XVII, 2011, 8145
  • [45] Cosmic-Ray Calibration of Lead Scintillation Monitor with Internal Trigger
    Baskov, V. A.
    Govorkov, B. B.
    Polyanskii, V. V.
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2014, 41 (05) : 140 - 143
  • [46] Absolute Calibration of Sensitivity of Multichannel Detectors Using Laser-Plasma X-Rays
    Shevel'ko, A. P.
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2023, 50 (SUPPL 2) : S178 - S186
  • [47] Cosmic-ray calibration of lead scintillation monitor with internal trigger
    V. A. Baskov
    B. B. Govorkov
    V. V. Polyanskii
    Bulletin of the Lebedev Physics Institute, 2014, 41 : 140 - 143
  • [48] A comprehensive calibration method of Ge detectors for low-level gamma-spectrometry measurements
    Pérez-Moreno, JP
    San Miguel, EG
    Bolivar, JP
    Aguado, JL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 491 (1-2) : 152 - 162
  • [49] Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements
    Wang, K.
    Samaranayake, S.
    Estrade, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1027
  • [50] New algorithm for studying the effect of self attenuation factor on the efficiency of γ-rays detectors
    Badawi, Mohamed S.
    Gouda, Mona M.
    Nafee, Sherif S.
    El-Khatib, Ahmed M.
    El-Mallah, Ekram A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 696 : 164 - 170