ACCURACY OF NONINVASIVE ANESTHETIC MONITORING IN THE ANESTHETIZED GIRAFFE (GIRAFFA CAMELOPARDALIS)

被引:7
作者
Bertelsen, Mads F. [1 ]
Grondahl, Carsten [1 ]
Stegmann, George F. [2 ]
Sauer, Cathrine [1 ]
Secher, Niels H. [3 ]
Hasenkam, J. Michael [4 ,5 ]
Damkjaer, Mads [6 ]
Aalkjaer, Christian [4 ]
Wang, Tobias [4 ]
机构
[1] Ctr Zoo & Wild Anim Hlth, Copenhagen Zoo, Roskildevej 38, DK-2000 Frederiksberg, Denmark
[2] Univ Pretoria, Dept Compan Anim Clin Studies, Corner Lynnwood Rd & Roper St, Hatfield, South Africa
[3] Univ Copenhagen, Norre Alle 41, DK-2200 Copenhagen N, Denmark
[4] Aarhus Univ, Nordre Ringgade 1, Aarhus C, Denmark
[5] Univ Witwatersrand, 1 Jan Smuts Ave, Johannesburg, South Africa
[6] Univ Southern Denmark, Dept Cardiovasc & Renal Res, Campusvej 55, DK-5230 Odense M, Denmark
关键词
Anesthesia; blood gas analysis; blood pressure; capnography; giraffe; monitoring; noninvasive; OSCILLOMETRIC BLOOD-PRESSURE; PULSE OXIMETRY; HORSES; DOGS; ARTERIAL; PRECISION; AGREEMENT; HEALTHY; DEVICES; CATS;
D O I
10.1638/2016-0276.1
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
This study evaluated the accuracy of pulse oximetry, capnography, and oscillometric blood pressure during general anesthesia in giraffes (Giraffa camelopardalis). Thirty-two giraffes anesthetized for physiologic experiments were instrumented with a pulse oximeter transmittance probe positioned on the tongue and a capnograph sampling line placed at the oral end of the endotracheal tube. A human size 10 blood pressure cuff was placed around the base of the tail, and an indwelling arterial catheter in the auricular artery continuously measured blood pressure. Giraffes were intermittently ventilated using a Hudson demand valve throughout the procedures. Arterial blood for blood gas analysis was collected at multiple time points. Relationships between oxygen saturation as determined by pulse oximetry and arterial oxygen saturation, between arterial carbon dioxide partial pressure and end-tidal carbon dioxide, and between oscillometric pressure and invasive arterial blood pressure were assessed, and the accuracy of pulse oximetry, capnography, and oscillometric blood pressure monitoring evaluated using Bland-Altman analysis. All three noninvasive methods provided relatively poor estimates of the reference values. Receiver operating characteristic curve fitting was used to determine cut-off values for hypoxia, hypocapnia, hypercapnia, and hypotension for dichotomous decision-making. Applying these cut-off values, there was reasonable sensitivity for detection of hypocapnia, hypercapnia, and hypotension, but not for hypoxemia. Noninvasive anesthetic monitoring should be interpreted with caution in giraffes and, ideally, invasive monitoring should be employed.
引用
收藏
页码:609 / 615
页数:7
相关论文
共 50 条
  • [1] MULTIPLE ANESTHETIC EVENTS IN A RETICULATED GIRAFFE (GIRAFFA-CAMELOPARDALIS)
    GEISER, DR
    MORRIS, PJ
    ADAIR, HS
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 1992, 23 (02) : 189 - 196
  • [2] Precision, accuracy, and costs of survey methods for giraffe Giraffa camelopardalis
    Lee, Derek E.
    Bond, Monica L.
    JOURNAL OF MAMMALOGY, 2016, 97 (03) : 940 - 948
  • [3] The giraffe (Giraffa camelopardalis) rumen microbiome
    Roggenbuck, Michael
    Sauer, Cathrine
    Poulsen, Morten
    Bertelsen, Mads F.
    Sorensen, Soren J.
    FEMS MICROBIOLOGY ECOLOGY, 2014, 90 (01) : 237 - 246
  • [4] SURGICAL CASTRATION OF SUBADULT GIRAFFE (GIRAFFA CAMELOPARDALIS)
    Borkowski, Rose
    Citino, Scott
    Bush, Mitch
    Wollenman, Paul
    Irvine, Brenda
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2009, 40 (04) : 786 - 790
  • [5] A Preliminary Study on the Siphon Mechanism in Giraffe (Giraffa camelopardalis)
    van der Walt, Marna Suzanne
    Daffue, Willem
    Goedhals, Jacqueline
    van der Merwe, Sean
    Deacon, Francois
    ANIMALS, 2022, 12 (23):
  • [6] The scent of the reticulated giraffe (Giraffa camelopardalis reticulata)
    Wood, WF
    Weldon, PJ
    BIOCHEMICAL SYSTEMATICS AND ECOLOGY, 2002, 30 (10) : 913 - 917
  • [7] Anatomy of the Mouth of the Giraffe (Giraffa camelopardalis rothschildi)
    Perez, William
    Michel, Virginie
    Jerbi, Hassen
    Vazquez, Noelia
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2012, 30 (01): : 322 - 329
  • [8] Assessment of contrafreeloading preferences in giraffe (Giraffa camelopardalis)
    Sasson-Yenor, Jacinthe
    Powell, David M.
    ZOO BIOLOGY, 2019, 38 (05) : 414 - 423
  • [9] The South African giraffe Giraffa camelopardalis giraffa: a conservation success story
    Deacon, Francois
    Tutchings, Andy
    ORYX, 2019, 53 (01) : 45 - 48
  • [10] Modified neck muscular system of the giraffe (Giraffa camelopardalis)
    Endo, H
    Yamagiwa, D
    Fujisawa, M
    Kimura, J
    Kurohmaru, M
    Hayashi, Y
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 1997, 179 (05) : 481 - 485