On the calibration of astigmatism particle tracking velocimetry for microflows

被引:100
作者
Cierpka, C. [1 ]
Rossi, M. [1 ]
Segura, R. [1 ]
Kaehler, C. J. [1 ]
机构
[1] Bundeswehr Univ Munich, Inst Fluid Mech & Aerodynam, D-85577 Neubiberg, Germany
关键词
3D3C PTV; microfluidics; astigmatism; MICROPARTICLE IMAGE VELOCIMETRY; FLOWS;
D O I
10.1088/0957-0233/22/1/015401
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Astigmatism particle tracking velocimetry (APTV) is a method to determine three components (3C) of the velocity field in a volume (3D) using a single camera. The depth position of the particles is coded by optical distortions caused by a cylindrical lens in the optical setup. This technique is particularly suited for microfluidic applications as measurement errors due to spatial averaging and depth of correlation, typically encountered with mu PIV approaches, are eliminated so that the measurement precision is enhanced. Unfortunately, the current state of the technique is limited by the small measurement region achievable with the current calibration procedures as well as by higher order image aberrations (Cierpka et al 2010 Meas. Sci. Technol. 21 045401). In order to extend the size of the measurement volume and to account for all image aberrations, a new intrinsic calibration procedure, based on the imaging function of the particles, is proposed in the paper at hand. It provides an extended measurement depth, taking into account all image aberrations. In this work, the calibration procedure was applied to a mu PIV arrangement but could also be implemented on macroscopic experimental setups. The calibration procedure is qualified with synthetic data as well as Poiseuille flow in a straight rectangular micro-channel with a cross-sectional area of 200 x 500 mu m(2). The three-dimensional velocity distribution of the whole channel was resolved via APTV with uncertainties of 0.9% and 3.7% of the centerline velocity, mu(c), for the in-plane and out-of-plane components, respectively. Further investigations using different cylindrical-lens focal lengths, magnifications and particle sizes provide information about achievable measurement depths and help to design and adapt the optimal system for the desired experiment.
引用
收藏
页数:10
相关论文
共 22 条
  • [1] Wavefront sensing for single view three-component three-dimensional flow velocimetry
    Angarita-Jaimes, N.
    McGhee, E.
    Chennaoui, M.
    Campbell, H. I.
    Zhang, S.
    Towers, C. E.
    Greenaway, A. H.
    Towers, D. P.
    [J]. EXPERIMENTS IN FLUIDS, 2006, 41 (06) : 881 - 891
  • [2] Wavefront sensing for three-component three-dimensional flow velocimetry in microfluidics
    Chen, S.
    Angarita-Jaimes, N.
    Angarita-Jaimes, D.
    Pelc, B.
    Greenaway, A. H.
    Towers, C. E.
    Lin, D.
    Towers, D. P.
    [J]. EXPERIMENTS IN FLUIDS, 2009, 47 (4-5) : 849 - 863
  • [3] A simple single camera 3C3D velocity measurement technique without errors due to depth of correlation and spatial averaging for microfluidics
    Cierpka, C.
    Segura, R.
    Hain, R.
    Kaehler, C. J.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (04)
  • [4] CIERPKA C, 2010, FACHT LAS STROM COTT
  • [5] CIERPKA C, 2010, 15 INT S APPL LAS TE
  • [6] Universal outlier detection for particle image velocimetry (PIV) and particle tracking velocimetry (PTV) data
    Duncan, J.
    Dabiri, D.
    Hove, J.
    Gharib, M.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (05)
  • [7] KUMAR A, 2010, MICROFLUID IN PRESS, DOI DOI 10.1007/S10404-010-0674-4
  • [8] Advanced particle-based velocimetry techniques for microscale flows
    Lee, Sang Joon
    Kim, Seok
    [J]. MICROFLUIDICS AND NANOFLUIDICS, 2009, 6 (05) : 577 - 588
  • [9] LESCHE C, 2008, P 1 EUR C MICR BOL I
  • [10] Micro-Particle Image Velocimetry (μPIV): Recent developments, applications, and guidelines
    Lindken, Ralph
    Rossi, Massimiliano
    Grosse, Sebastian
    Westerweel, Jerry
    [J]. LAB ON A CHIP, 2009, 9 (17) : 2551 - 2567