Imaging artifacts of medical instruments in ultrasound-guided interventions

被引:65
作者
Huang, Jinlan
Triedman, John K.
Vasilyev, Nikolay V.
Suematsu, Yoshihiro
Cleveland, Robin E.
Dupont, Pierre E.
机构
[1] Boston Univ, Dept Aerosp & Mech Engn, Boston, MA 02215 USA
[2] Childrens Hosp, Dept Cardiol, Div Basic Cardiovasc Res, Boston, MA 02115 USA
[3] Univ Tokyo, Dept Cardiothorac Surg, Tokyo, Japan
关键词
imaging artifacts; medical instruments; ultrasound-guided interventions;
D O I
10.7863/jum.2007.26.10.1303
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. Real-time 3-dimensional (3D) ultrasound imaging has the potential to become a dominant imaging technique for minimally invasive surgery. One barrier to its widespread use is that surgical instruments generate imaging artifacts, which can obfuscate their location, orientation, and geometry and obscure nearby tissue. The purpose of this study was to identify and describe the types of artifacts which could be produced by metallic instruments during interventions guided by 3D ultrasound imaging. Methods. Three imaging studies were performed. First, imaging artifacts from stainless steel rods were identified in vitro and acoustically characterized. Second, 3 typical minimally invasive instruments were imaged (in vitro and in vivo), and their artifacts were analyzed. The third study compared the intensity of imaging artifacts (in vitro and in vivo) from stainless steel rods with rods composed of 3 different materials and stainless steel rods with roughened and coated surfaces. Results. For the stainless steel rods, all observed artifacts are described and illustrated, and their physical origins are explained. Artifacts from the 3 minimally invasive instruments are characterized with the use of the artifacts observed with the rods. Finally, it is shown that artifacts can be greatly reduced through the use of alternate materials or by surface modification. Conclusions. Instrument artifacts in 3D ultrasound images can be more confusing than those from the same instruments imaged in 2 dimensions. Real-time 3D ultrasound imaging can, however, be used effectively for in vivo imaging of minimally invasive instruments by using artifact mitigation techniques, including careful selection of probe and incision locations, as well as by instrument modification.
引用
收藏
页码:1303 / 1322
页数:20
相关论文
共 58 条
[11]   Clinical utility of three-dimensional US [J].
Downey, DB ;
Fenster, A ;
Williams, JC .
RADIOGRAPHICS, 2000, 20 (02) :559-571
[12]  
EVANS RG, 1991, JAMA-J AM MED ASSOC, V265, P1155
[13]   Circumferential resonance modes of solid elastic cylinders excited by obliquely incident acoustic waves [J].
Fan, Y ;
Honarvar, F ;
Sinclair, AN ;
Jafari, MR .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (01) :102-113
[14]   SOUND SCATTERING BY SOLID CYLINDERS AND SPHERES [J].
FARAN, JJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1951, 23 (04) :405-418
[15]  
GARDNER F J, 1980, Medical Ultrasound, V4, P19
[16]   SLICE-THICKNESS ARTIFACTS IN GRAY-SCALE ULTRASOUND [J].
GOLDSTEIN, A ;
MADRAZO, BL .
JOURNAL OF CLINICAL ULTRASOUND, 1981, 9 (07) :365-375
[17]   RANGE AMBIGUITIES IN REAL-TIME ULTRASOUND [J].
GOLDSTEIN, A .
JOURNAL OF CLINICAL ULTRASOUND, 1981, 9 (02) :83-90
[18]  
GOMBERG J, 1982, J ULTRAS MED, V1, P120
[19]   Coating agent permits improved visualization of biopsy needles during sonography [J].
Gottlieb, RH ;
Robinette, WB ;
Rubens, DJ ;
Hartley, DF ;
Fultz, PJ ;
Violante, MR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (05) :1301-1302
[20]   THE SONOGRAPHIC APPEARANCE AND CONTRAST ENHANCEMENT OF PUNCTURE NEEDLES [J].
HECKEMANN, R ;
SEIDEL, KJ .
JOURNAL OF CLINICAL ULTRASOUND, 1983, 11 (05) :265-268