Univariate and multivariate calibration strategies in combination with laser-induced breakdown spectroscopy (LIBS) to determine Ti on sunscreen: A different sample preparation procedure

被引:24
作者
Speranca, Marco Aurelio [1 ]
Andrade, Daniel Fernandes [1 ]
Castro, Jeyne Pricylla [1 ]
Pereira-Filho, Edenir Rodrigues [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Chem, High Way SP 310,Km 235,POB 676, BR-13565905 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Sunscreen; LIBS; Liquid sample immobilization; Univariate and multivariate calibration; PVA; DATA NORMALIZATION; CLASSIFICATION; NANOPARTICLES;
D O I
10.1016/j.optlastec.2018.08.056
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Sunscreen is a cream which the intended use is to protect the human skin from ultraviolet radiation (UV) from the sun. Physical (inorganic) or chemical (organic) filters could be used to scatter the UV radiation, being TiO2, one physical filter widely used in its formulation. To determine Ti concentrations on sunscreen, laborious and unsafe procedures must be performed involving strong acids and high temperatures in furnaces. With laserinduced breakdown spectroscopy (LIBS) the possibility of determining this element with minimal sample preparation is feasible. In this study, Ti concentration on sunscreen was determined through several calibration approaches (univariate and multivariate) with LIBS and an unusual sample preparation for sunscreen using a solution of poly(vinyl)alcohol (PVA) to immobilize the sample, converting its matrix to solid. Five samples were prepared and analyzed by inductively coupled plasma optical emission spectrometry (ICP OES) and the Ti concentration ranged from 0.45 to 1.58%. Standard errors for cross validation (SECV) and recoveries were 0.07% and 97-104% using multiple linear regression (MLR) with information from two Ti emission lines: I 498.17 nm and I 499.11 nm.
引用
收藏
页码:648 / 653
页数:6
相关论文
共 31 条
[1]   Comparison of ICP OES and LIBS Analysis of Medicinal Herbs Rich in Flavonoids from Eastern Europe [J].
Andrade, Daniel F. ;
Pereira-Filho, Edenir Rodrigues ;
Konieczynski, Pawel .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2017, 28 (05) :838-847
[2]  
Andrade DF, 2017, ANAL METHODS-UK, V9, P5156, DOI [10.1039/C7AY01049D, 10.1039/c7ay01049d]
[3]   Portable X-ray fluorescence spectroscopy as a rapid screening technique for analysis of TiO2 and ZnO in sunscreens [J].
Bairi, Venu Gopal ;
Lim, Jin-Hee ;
Quevedo, Ivan R. ;
Mudalige, Thilak K. ;
Linder, Sean W. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 116 :21-27
[4]   Determination of Cd, Co, Cr, Cu, Ni and Pb in cosmetic samples using a simple method for sample preparation [J].
Batista, Erica Ferreira ;
Augusto, Amanda dos Santos ;
Pereira-Filho, Edenir Rodrigues .
ANALYTICAL METHODS, 2015, 7 (01) :329-335
[5]  
Brereton A. G., 2003, CALIBRATION, DOI [10.1002/0470863242.ch5, DOI 10.1002/0470863242.CH5]
[6]  
Bunhu T., 2011, S AFR J CHEM, P139
[7]   Current sunscreen controversies: a critical review [J].
Burnett, Mark E. ;
Wang, Steven Q. .
PHOTODERMATOLOGY PHOTOIMMUNOLOGY & PHOTOMEDICINE, 2011, 27 (02) :58-67
[8]   Twelve different types of data normalization for the proposition of classification, univariate and multivariate regression models for the direct analyses of alloys by laser-induced breakdown spectroscopy (LIBS) [J].
Castro, Jeyne Pricylla ;
Pereira-Filho, Edenir Rodrigues .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (10) :2005-2014
[9]   Direct determination of Ca, K, Mg, Na, P, S, Fe and Zn in bivalve mollusks by wavelength dispersive X-ray fluorescence (WDXRF) and laser-induced breakdown spectroscopy (LIBS) [J].
Costa, Vinicius Camara ;
Carqueija Amorim, Fabio Alan ;
de Babos, Diego Victor ;
Pereira-Filho, Edenir Rodrigues .
FOOD CHEMISTRY, 2019, 273 :91-98
[10]   Rapid analysis of titanium dioxide nanoparticles in sunscreens using single particle inductively coupled plasma-mass spectrometry [J].
Dan, Yongbo ;
Shi, Honglan ;
Stephan, Chady ;
Liang, Xinhua .
MICROCHEMICAL JOURNAL, 2015, 122 :119-126