Identification of crack depths from eddy current testing signal

被引:23
作者
Fukutomi, H [1 ]
Huang, HY [1 ]
Takagi, T [1 ]
Tani, J [1 ]
机构
[1] Inst Fluid Sci, Aoba Ku, Sendai, Miyagi 9808577, Japan
关键词
eddy current testing; steam generator tubes; inverse problems; finite element methods; reduced magnetic vector potentials; pre-computed unflawed database approach; meshless crack representation technique; trust region method;
D O I
10.1109/20.717674
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper demonstrates the identification of crack depths using signals obtained from eddy current testing (ECT), The identification method is based on finite elements with the pre-computed unflawed database approach and a meshless crack representation technique, and parameter estimation in non-linear problems. Four different cracks are estimated by using laboratory data.
引用
收藏
页码:2893 / 2896
页数:4
相关论文
共 11 条
[1]  
Badics Z, 1997, STUD APPL ELECTROMAG, V12, P303
[2]  
CURTER RG, 1987, TR8712 RIC U DEP MAT
[3]  
FUKUTOMI H, IN PRESS ELECTROMAGN
[4]  
KAMEARI A, 1990, COMPEL, V9, P230
[5]  
Kojima F, 1997, STUD APPL ELECTROMAG, V12, P279
[6]  
More J.J., 1983, MATH PROGRAMMING STA, P258
[7]   THEORY OF EDDY-CURRENT INVERSION [J].
NORTON, SJ ;
BOWLER, JR .
JOURNAL OF APPLIED PHYSICS, 1993, 73 (02) :501-512
[8]   AN EDDY-CURRENT MODEL FOR 3-DIMENSIONAL INVERSION [J].
SABBAGH, HA ;
SABBAGH, LD .
IEEE TRANSACTIONS ON MAGNETICS, 1986, 22 (04) :282-291
[9]  
Shimone J, 1996, JSAEM APPL ELECTROM, V5, P12
[10]  
Takagi T, 1997, STUD APPL ELECTROMAG, V12, P9