共 47 条
Partial volume correction in arterial spin labeling perfusion MRI: A method to disentangle anatomy from physiology or an analysis step too far?
被引:35
作者:
Chappell, Michael A.
[1
,2
,3
,4
]
Kennedy McConnell, Flora A.
[1
,2
,3
]
Golay, Xavier
[5
]
Gunther, Matthias
[6
,7
,8
]
Hernandez-Tamames, Juan A.
[9
]
van Osch, Matthias J.
[10
]
Asllani, Iris
[11
,12
]
机构:
[1] Univ Nottingham, Sch Med, Radiol Sci Mental Hlth & Clin Neurosci, Nottingham, England
[2] Univ Nottingham, Sir Peter Mansfield Imaging Ctr, Sch Med, Nottingham, England
[3] Univ Nottingham, Nottingham Biomed Res Ctr, Queens Med Ctr, Nottingham, England
[4] Univ Oxford, Wellcome Ctr Integrat Neuroimaging, Nuffield Dept Clin Neurosci, Oxford, England
[5] UCL Inst Neurol, Dept Brain Repair & Rehabil, London, England
[6] Fraunhofer MEVIS, Bremen, Germany
[7] Univ Bremen, Bremen, Germany
[8] Mediri GmbH, Heidelberg, Germany
[9] Erasmus MC, Radiol & Nucl Med Dept, Rotterdam, Netherlands
[10] Leiden Univ, CJ Gorter Ctr High Field MRI, Radiol Dept, Med Ctr, Leiden, Netherlands
[11] Univ Sussex, Dept Neurosci, Clin Imaging Sci Ctr, Brighton, E Sussex, England
[12] Rochester Inst Technol, Dept Biomed Engn, Rochester, NY 14623 USA
来源:
基金:
英国工程与自然科学研究理事会;
关键词:
Arterial spin labeling;
Partial volume effect;
Perfusion;
Cerebral Blood Flow;
MRI;
fMRI;
Atrophy;
Aging and dementia;
CEREBRAL-BLOOD-FLOW;
MILD COGNITIVE IMPAIRMENT;
ALZHEIMER-DISEASE;
BRAIN ATROPHY;
PET;
HYPOPERFUSION;
TOMOGRAPHY;
TOOLBOX;
D O I:
10.1016/j.neuroimage.2021.118236
中图分类号:
Q189 [神经科学];
学科分类号:
071006 ;
摘要:
The mismatch in the spatial resolution of Arterial Spin Labeling (ASL) MRI perfusion images and the anatomy of functionally distinct tissues in the brain leads to a partial volume effect (PVE), which in turn confounds the estimation of perfusion into a specific tissue of interest such as gray or white matter. This confound occurs because the image voxels contain a mixture of tissues with disparate perfusion properties, leading to estimated perfusion values that reflect primarily the volume proportions of tissues in the voxel rather than the perfusion of any particular tissue of interest within that volume. It is already recognized that PVE influences studies of brain perfusion, and that its effect might be even more evident in studies where changes in perfusion are co-incident with alterations in brain structure, such as studies involving a comparison between an atrophic patient population vs control subjects, or studies comparing subjects over a wide range of ages. However, the application of PVE correction (PVEc) is currently limited and the employed methodologies remain inconsistent. In this article, we outline the influence of PVE in ASL measurements of perfusion, explain the main principles of PVEc, and provide a critique of the current state of the art for the use of such methods. Furthermore, we examine the current use of PVEc in perfusion studies and whether there is evidence to support its wider adoption. We conclude that there is sound theoretical motivation for the use of PVEc alongside conventional, 'uncorrected', images, and encourage such combined reporting. Methods for PVEc are now available within standard neuroimaging toolboxes, which makes our recommendation straightforward to implement. However, there is still more work to be done to establish the value of PVEc as well as the efficacy and robustness of existing PVEc methods.
引用
收藏
页数:8
相关论文