Fracture Repair in the Distal Radius in Postmenopausal Women: A Follow-Up 2 Years Postfracture Using HRpQCT

被引:27
作者
de Jong, Joost J. A. [1 ,2 ]
Heyer, Frans L. [1 ,3 ,4 ]
Arts, Jacobus J. C. [5 ,6 ]
Poeze, Martijn [1 ,3 ]
Keszei, Andras P. [7 ]
Willems, Paul C. [5 ,6 ]
van Rietbergen, Bert [8 ]
Geusens, Piet P. [2 ,6 ,9 ]
van den Bergh, Joop P. W. [1 ,2 ,4 ,9 ]
机构
[1] Maastricht Univ, Med Ctr, NUTRIM Sch Nutr & Translat Res Metab, NL-6200 MD Maastricht, Netherlands
[2] Maastricht Univ, Med Ctr, Dept Rheumatol, POB 5800, NL-6202 AZ Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Dept Surg, NL-6200 MD Maastricht, Netherlands
[4] VieCuri Med Ctr, Dept Internal Med, Venlo, Netherlands
[5] Maastricht Univ, Med Ctr, Dept Orthoped Surg, NL-6200 MD Maastricht, Netherlands
[6] Maastricht Univ, Med Ctr, CAPHRI Sch Publ Hlth & Primary Care, NL-6200 MD Maastricht, Netherlands
[7] Uniklin RWTH Aachen Univ, Dept Med Informat, Aachen, Germany
[8] Eindhoven Univ Technol, Fac Biomed Engn, POB 513, NL-5600 MB Eindhoven, Netherlands
[9] Hasselt Univ, Fac Med & Life Sci, Hasselt, Belgium
关键词
FRACTURE REPAIR; DISTAL RADIUS; POSTMENOPAUSAL WOMEN; HRpQCT; QUANTITATIVE COMPUTED-TOMOGRAPHY; BONE-DENSITY; MICROARCHITECTURE; PRECISION; ACCURACY;
D O I
10.1002/jbmr.2766
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fracture healing is characterized by an intense increase in modeling and remodeling of bone, which allows removal of the cast after a stable distal radius fracture within 3 to 5 weeks. However, at that time, bone strength has not recovered yet. We studied the changes in bone mineral density (BMD), microarchitecture, and bone stiffness after a distal radius fracture during a 2-year follow-up in comparison to the contralateral side and the association between the 2-year stiffness and baseline BMD, microarchitecture, and early changes in these parameters. The fractured side of 14 postmenopausal women (mean age 64 8 years) with a conservatively treated distal radius fracture was scanned by high-resolution peripheral quantitative computed tomography (HRpQCT) at 1 to 2,3 to 4,6 to 8, and 12 weeks and 2 years postfracture. The same region contralaterally was scanned as well at the 2-year visit. BMD, microarchitecture, and stiffness parameters were determined and the fracture side was compared with the contralateral side using a linear mixed-effect model. Spearman's correlation was used to correlate the 2-year bone stiffness with baseline BMD, microarchitecture, and early 3-month changes in these parameters. Two years postfracture, cortical and trabecular thickness and torsional and bending stiffness were significantly higher at the fractured side compared with the nonfractured side (21%, 55%, 31%, and 29%, respectively, p < 0.05), whereas BMD was similar. Two-year torsional and bending stiffness correlated significantly with baseline BMD and cortical perimeter (vertical bar rho vertical bar >= 0.63, p < 0.016) but not with early changes in bone parameters. Using HRpQCT, this study illustrates that fracture healing is not completed by the time the cast is removed. We showed that from 6 weeks to 2 years postfracture, large changes occur in BMD, microarchitecture, and biomechanical parameters at the fractured side, which were fully recovered after 2 years in comparison to the nonfractured contralateral side. Interestingly, higher 2-year torsional and bending stiffness were associated with lower BMD and higher cortical perimeter at baseline. (C) 2015 American Society for Bone and Mineral Research.
引用
收藏
页码:1114 / 1122
页数:9
相关论文
共 16 条
[1]   In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography [J].
Boutroy, S ;
Bouxsein, ML ;
Munoz, F ;
Delmas, PD .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2005, 90 (12) :6508-6515
[2]   Bone micro-architecture and determinants of strength in the radius and tibia: age-related changes in a population-based study of normal adults measured with high-resolution pQCT [J].
Dalzell, N. ;
Kaptoge, S. ;
Morris, N. ;
Berthier, A. ;
Koller, B. ;
Braak, L. ;
van Rietbergen, B. ;
Reeve, J. .
OSTEOPOROSIS INTERNATIONAL, 2009, 20 (10) :1683-1694
[3]   Assessment of the healing process in distal radius fractures by high resolution peripheral quantitative computed tomography [J].
de Jong, Joost J. A. ;
Willems, Paul C. ;
Arts, Jacobus J. ;
Bours, Sandrine G. P. ;
Brink, Peter R. G. ;
van Geel, Tineke A. C. M. ;
Poeze, Martijn ;
Geusens, Piet P. ;
van Rietbergen, Bert ;
van den Bergh, Joop P. W. .
BONE, 2014, 64 :65-74
[4]   Fracture healing: mechanisms and interventions [J].
Einhorn, Thomas A. ;
Gerstenfeld, Louis C. .
NATURE REVIEWS RHEUMATOLOGY, 2015, 11 (01) :45-54
[5]  
Hildebrandt EM, 2015, J CLIN DENSITOM
[6]  
Hilderbrand T, 1999, J BONE MINER RES, V17, P1167
[7]  
Laib A, 1998, Technol Health Care, V6, P329
[8]   Accuracy and precision of radio stereometric analysis in the measurement of three-dimensional micromotion in a fracture model of the distal radius [J].
Madanat, R ;
Mäkinen, TJ ;
Moritz, N ;
Mattila, KT ;
Aro, HT .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (02) :481-488
[9]   The biology of fracture healing [J].
Marsell, Richard ;
Einhorn, Thomas A. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (06) :551-555
[10]   ANALYSIS OF SERIAL MEASUREMENTS IN MEDICAL-RESEARCH [J].
MATTHEWS, JNS ;
ALTMAN, DG ;
CAMPBELL, MJ ;
ROYSTON, P .
BRITISH MEDICAL JOURNAL, 1990, 300 (6719) :230-235