Influence of aspect ratio of tunnel on smoke temperature distribution under ceiling in near field of fire source

被引:99
作者
Ji, Jie [1 ,2 ]
Bi, Yubo [1 ]
Venkatasubbaiah, Kondapalli [3 ]
Li, Kaiyuan [4 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China
[2] Univ Sci & Technol China, Inst Adv Technol, Hefei 230088, Anhui, Peoples R China
[3] Indian Inst Technol Hyderabad, Dept Mech Engn, Hyderabad 502205, Andhra Pradesh, India
[4] Aalto Univ, Dept Civil & Struct Engn, Espoo 02150, Finland
基金
中国国家自然科学基金;
关键词
Tunnel fire; Tunnel width; Mass loss rate; Smoke temperature; Pool fire; HEAT RELEASE RATE; LONGITUDINAL VENTILATION; GAS TEMPERATURES; BURNING RATE; VELOCITY; FLOW;
D O I
10.1016/j.applthermaleng.2016.06.086
中图分类号
O414.1 [热力学];
学科分类号
摘要
Former studies usually used model tunnels with fixed width while in reality the tunnel width can be different between different tunnels. In the current study, a set of small scale experiments were conducted using a model tunnel with adjustable width. The influences of tunnel width on mass loss rate, maximum smoke temperature and temperature distributions under the ceiling were investigated. Results show that under the current experimental conditions, the tunnel width has little influence on the mass loss rate and maximum smoke temperature under the ceiling. However, tunnel width significantly affects the smoke temperature distribution. The smoke temperature under the ceiling, decays more slowly at both longitudinal and transverse directions as tunnel width decreases. Empirical models are developed for both longitudinal and transverse temperature distributions which take into account the effects of tunnel width and dimensionless heat release rate. The models include exponential type functions. The index of the exponential function is proportional to the dimensionless heat release rate to the power of n. The value of n is 0.4 for longitudinal distribution and 0.5 for transverse distribution. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1094 / 1102
页数:9
相关论文
共 24 条
[1]  
[Anonymous], 2011, THESIS
[2]   The influence of tunnel geometry and ventilation on the heat release rate of a fire [J].
Carvel, RO ;
Beard, AN ;
Jowitt, PW ;
Drysdale, DD .
FIRE TECHNOLOGY, 2004, 40 (01) :5-26
[3]   Experimental study on transverse smoke temperature distribution in road tunnel fires [J].
Fan, C. G. ;
Ji, J. ;
Gao, Z. H. ;
Sun, J. H. .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2013, 37 :89-95
[4]   Effect of tunnel cross section on gas temperatures and heat fluxes in case of large heat release rate [J].
Fan, Chuan Gang ;
Li, Ying Zhen ;
Ingason, Haukur ;
Lonnermark, Anders .
APPLIED THERMAL ENGINEERING, 2016, 93 :405-415
[5]   Experimental analysis of the influence of accumulated upper hot layer on the maximum ceiling gas temperature by a modified virtual source origin concept [J].
Gao, Z. H. ;
Ji, J. ;
Fan, C. G. ;
Sun, J. H. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 84 :262-270
[6]   Influence of sidewall restriction on the maximum ceiling gas temperature of buoyancy-driven thermal flow [J].
Gao, Z. H. ;
Ji, J. ;
Fan, C. G. ;
Sun, J. H. ;
Zhu, J. P. .
ENERGY AND BUILDINGS, 2014, 84 :13-20
[7]   An investigation of the detailed flame shape and flame length under the ceiling of a channel [J].
Gao, Zihe ;
Ji, Jie ;
Wan, Huaxian ;
Li, Kaiyuan ;
Sun, Jinhua .
PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2015, 35 :2657-2664
[8]   Model scale tunnel fire tests with longitudinal ventilation [J].
Ingason, Haukur ;
Li, Ying Zhen .
FIRE SAFETY JOURNAL, 2010, 45 (6-8) :371-384
[9]   Experimental investigation on influence of different transverse fire locations on maximum smoke temperature under the tunnel ceiling [J].
Ji, J. ;
Fan, C. G. ;
Zhong, W. ;
Shen, X. B. ;
Sun, J. H. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (17-18) :4817-4826
[10]   Experimental study on behavior of sidewall fires at varying height in a corridor-like structure [J].
Ji, Jie ;
Fu, Yanyun ;
Li, Kaiyuan ;
Sun, Jinhua ;
Fan, Chuangang ;
Shi, Wenxi .
PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2015, 35 :2639-2646