Nanoliter-volume protein enrichment, tryptic digestion, and partial separation based on isoelectric points by CE for MALDI mass spectral analysis

被引:16
作者
Nesbitt, Chandra A. [1 ]
Jurcic, Kristina [1 ]
Yeung, Ken K. -C. [1 ,2 ]
机构
[1] Univ Western Ontario, Dept Chem, London, ON, Canada
[2] Univ Western Ontario, Dept Biochem, London, ON, Canada
关键词
discontinuous buffer; Fractionation; MS; pH junction; preconcentration;
D O I
10.1002/elps.200700339
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sequence-specific proteolysis is an important part of protein identification by MS. Digestion of protein is commonly performed in-solution, in sample vials with volumes ranging from milli- to microliters. When digestion is performed with a sample volume below 1 mu L, handling of solution and potential sample loss via adsorption become significant issues. In this report, a proof of concept for the digestion of a small volume protein solution inside a capillary was demonstrated using a discontinuous buffer system previously studied (Nes-bitt, C. A., et al. J. Chromatogn A 2005, 1073, 175-180). Upon voltage application, a pH junction was created by the discontinuous buffer. Using myoglobin as an example, the protein molecules were enriched at the junction with an estimated volume of a few nano-liters. A protease, trypsin, was then introduced to myoglobin at the junction by coenrichment to induce in-capillary digestion. The voltage application was then suspended to provide the necessary time (2 h) for the proteolysis to proceed. When completed, voltage application was resumed, and the discontinuous buffer reconcentrated the peptides formed from digestion. Importantly, the refocused peptides appeared to roughly elute according to their pIs, resulting in a partial separation. Direct sample deposition from capillary was performed to facilitate mass spectral analysis by MALDI. The partial separation, according to pI, offered the potential benefits of MALDI MS signal enhancement and provided supplementary pI information for peptide identity assignment.
引用
收藏
页码:466 / 474
页数:9
相关论文
共 41 条
[1]   Multistep microreactions with proteins using electrocapture technology [J].
Astorga-Wells, J ;
Bergman, T ;
Jörnvall, H .
ANALYTICAL CHEMISTRY, 2004, 76 (09) :2425-2429
[2]   On-line system for peptide mapping by capillary electrophoresis at sub-micromolar concentrations [J].
Bonneil, E ;
Waldron, KC .
TALANTA, 2000, 53 (03) :687-699
[3]   Analysis of recombinant DNA-derived glycoproteins via highperformance capillary electrophoresis coupled with off-line matrix-assisted laser desorption ionization time-of-flight mass spectrometry [J].
Chakel, JA ;
Pungor, E ;
Hancock, WS ;
Swedberg, SA .
JOURNAL OF CHROMATOGRAPHY B, 1997, 689 (01) :215-220
[4]   Integrated sample processing system involving on-column protein adsorption, sample washing, and enzyme digestion for protein identification by LC-ESI MS/MS [J].
Craft, D ;
Li, L .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2649-2655
[5]   Microcolumn capture and digestion of proteins combined with mass spectrometry for protein identification [J].
Craft, D ;
Doucette, A ;
Li, L .
JOURNAL OF PROTEOME RESEARCH, 2002, 1 (06) :537-547
[6]   Phospholipid bilayer coatings for the separation of proteins in capillary electrophoresis [J].
Cunliffe, JM ;
Baryla, NE ;
Lucy, CA .
ANALYTICAL CHEMISTRY, 2002, 74 (04) :776-783
[7]   Protein concentration and enzyme digestion on microbeads for MALDI-TOF peptide mass mapping of proteins from dilute solutions [J].
Doucette, A ;
Craft, D ;
Li, L .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3355-3362
[8]   The proteomic reactor: A microfluidic device for processing minute amounts of protein prior to mass spectrometry analysis [J].
Ethier, Martin ;
Hou, Weimin ;
Duewel, Henry S. ;
Figeys, Daniel .
JOURNAL OF PROTEOME RESEARCH, 2006, 5 (10) :2754-2759
[9]   Integrated preconcentration SDS-PAGE of proteins in microchips using photopatterned cross-linked polyacrylamide gels [J].
Hatch, Anson V. ;
Herr, Amy E. ;
Throckmorton, Daniel J. ;
Brennan, James S. ;
Singh, Anup K. .
ANALYTICAL CHEMISTRY, 2006, 78 (14) :4976-4984
[10]   Capillary isoelectric focusing without carrier ampholytes [J].
Huang, TM ;
Wu, XZ ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :4758-4761