Multiple-electrode radiofrequency ablation of in vivo porcine liver - Comparative studies of consecutive monopolar, switching monopolar versus multipolar modes

被引:43
作者
Lee, Jeong Min
Han, Joon Koo
Kim, Hyo Cheol
Kim, Se Hyung
Kim, Kyung Won
Joo, Seung Moon
Choi, Byung Ihn
机构
[1] Seoul Natl Univ Hosp, Dept Diagnost Radiol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Inst Radiat Med, Dept Radiol, Seoul, South Korea
[3] Seoul Natl Univ Hosp, Clin Res Inst, Seoul 110744, South Korea
关键词
liver; interventional procedures; thermal ablation; radiofrequency ablation; experimental study; INTERNALLY COOLED ELECTRODES; EX-VIVO; HEPATOCELLULAR-CARCINOMA; TUMOR ABLATION; BOVINE LIVER; LOCAL RECURRENCE; SINGLE SESSION; RISK-FACTORS; COAGULATION; BIPOLAR;
D O I
10.1097/RLI.0b013e3180661aad
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the in vivo efficiency of 2 multiple-electrode radiofrequency (RF) systems to create confluent areas of coagulation in porcine liver, compared with consecutive overlapping ablation. Materials and Methods: A total of 18 coagulations were created with 3 RF devices and 3 internally cooled electrodes at laparotomy in 6 female pigs. RF was applied to the porcine livers in a consecutive, monopolar mode (group A), in a switching monopolar mode (group B), or in a multipolar mode (group C) Energy efficiency values for the RF systems, shape and dimensions, and the coefficients of variation of the coagulation zones were compared in the 3 groups. Results: The duration of the RF ablation procedures in groups A, B, and C were 36 minutes, 18 minutes, and 21.2 +/- 1.9 minutes. The average energy delivered to produce 1 cm(3) coagulation was greater in group A (5.6 +/- 2.3 kJ/cm(3)) than in group B (1.8 +/- 0.5 kJ/cm(3)) or in group C (2.0 +/- 0.8 kJ/cm(3)) (p < 0.05). The mean volumes of the coagulations in groups A, B, and C were 28.8 +/- 13.2 cm(3) in group A, 49.1 +/- 12.3 cm(3) in group B, and 40.6 +/- 16.3 cm(3) in group C, respectively (P = 0.07). Regarding the shape of the coagulations, the coagulations of groups B (isoperimetric ratio; 0.88) and C (0.84) were more spherical than those of group A (0.69) (P < 0.05). In addition, the coefficients of variation of the volumes of the ablation zones in groups A, B, and C were 0.46, 0.25, and 0.40, respectively. Conclusions: Multiple-electrode RF systems in switching monopolar and multipolar modes more efficiently created a larger, confluent, spherical-shaped coagulation than conventional consecutive RF ablation.
引用
收藏
页码:676 / 683
页数:8
相关论文
共 34 条
[21]  
IMAGE J, IMAGING PROCESSING A
[22]   Risk factors for local recurrence of small hepatocellular carcinoma tumors after a single session, single application of percutaneous radiofrequency ablation [J].
Komorizono, Y ;
Oketani, M ;
Sako, K ;
Yamasaki, N ;
Shibatou, T ;
Maeda, M ;
Kohara, K ;
Shigenobu, S ;
Ishibashi, K ;
Arima, T .
CANCER, 2003, 97 (05) :1253-1262
[23]   Multiple-electrode radiofrequency ablation creates confluent areas of necrosis: In vivo porcine liver results [J].
Laeseke, Paul F. ;
Sampson, Lisa A. ;
Haemmerich, Dieter ;
Brace, Christopher L. ;
Fine, Jason P. ;
Frey, Tina M. ;
Winter, Thomas C., III ;
Lee, Fred T., Jr. .
RADIOLOGY, 2006, 241 (01) :116-124
[24]   Multiple probe radiofrequency ablation: Pilot study in an animal model [J].
Lee, FT ;
Haemmerich, D ;
Wright, AS ;
Mahvi, DM ;
Sampson, LA ;
Webster, JG .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (11) :1437-1442
[25]   Switching monopolar radiofrequency ablation technique using multiple, internally cooled electrodes and a multichannel generator - Ex vivo and in vivo pilot study [J].
Lee, Jeong Min ;
Han, Joon Koo ;
Kim, Hyo Cheol ;
Choi, Young Hun ;
Kim, Se Hyung ;
Choi, Jin Young ;
Choi, Byung Ihn .
INVESTIGATIVE RADIOLOGY, 2007, 42 (03) :163-171
[26]   A comparative experimental study of the in-vitro efficiency of hypertonic saline-enhanced hepatic bipolar and monopolar radiofrequency ablation [J].
Lee, JM ;
Han, JK ;
Kim, SH ;
Sohn, KL ;
Lee, KH ;
Ah, SK ;
Choi, BI .
KOREAN JOURNAL OF RADIOLOGY, 2003, 4 (03) :163-169
[27]   Radiofrequency ablation of the porcine liver in vivo: Increased coagulation with an internally cooled perfusion electrode [J].
Lee, JM ;
Han, JK ;
Chang, JM ;
Chung, SY ;
Kim, SH ;
Lee, JY ;
Lee, MW ;
Choi, BI .
ACADEMIC RADIOLOGY, 2006, 13 (03) :343-352
[28]   Saline-enhanced hepatic radiofrequency ablation using a perfused-cooled electrode: Comparison of dual probe bipolar mode with monopolar and single probe bipolar modes [J].
Lee, JM ;
Han, JK ;
Kim, SH ;
Lee, JY ;
Kim, DJ ;
Lee, MW ;
Cho, GG ;
Han, CJ ;
Choi, BI .
KOREAN JOURNAL OF RADIOLOGY, 2004, 5 (02) :121-127
[29]   Early-stage hepatocellular carcinoma in patients with cirrhosis: Long-term results of percutaneous image-guided radiofrequency ablation [J].
Lencioni, R ;
Cioni, D ;
Crocetti, L ;
Franchini, C ;
Della Pina, C ;
Lera, J ;
Bartolozzi, C .
RADIOLOGY, 2005, 234 (03) :961-967
[30]   LIMITATIONS OF TETRAZOLIUM SALTS IN DELINEATING INFARCTED BRAIN [J].
LISZCZAK, TM ;
HEDLEYWHYTE, ET ;
ADAMS, JF ;
HAN, DH ;
KOLLURI, VS ;
VACANTI, FX ;
HEROS, RC ;
ZERVAS, NT .
ACTA NEUROPATHOLOGICA, 1984, 65 (02) :150-157