A validated LC-MS/MS assay for the quantification of phosphodiesterase-5 inhibitors in human plasma

被引:6
作者
de Souza Madeira, Camilla Regina [1 ]
Fachi, Mariana Millan [1 ]
Concentino, Victor [1 ]
Cobre, Alexandre de Fatima [1 ]
Leal Badaro Trindade, Angela Cristina [1 ]
Goncalves, Alan Guilherme [1 ]
Pontarolo, Roberto [1 ]
机构
[1] Univ Fed Parana, Dept Pharm, 632 Lothario Meissner Ave, BR-80210170 Curitiba, Parana, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2021年 / 1179卷
关键词
Phosphodiesterase-5; inhibitors; LC-MS/MS; Plasma; Validation; Therapeutic monitoring; ERECTILE DYSFUNCTION; DOUBLE-BLIND; LODENAFIL CARBONATE; ORAL-THERAPY; EFFICACY; SAFETY; TOLERABILITY; TADALAFIL; MULTICENTER; VARDENAFIL;
D O I
10.1016/j.jchromb.2021.122829
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Phosphodiesterase inhibitors (PDE5i) are considered the first line therapy for erectile dysfunction. All PDE5i available on the market are structurally related; their main differences relate to their pharmacokinetic parameters. For these treatments to be effective and safe, it is necessary that these drugs are in the appropriate doses and that they reach adequate concentrations in the plasma. For this purpose, it is essential to perform therapeutic monitoring using bioanalytical methods. In this way, the present work aimed to develop and validate a new bioanalytical method, based on LC-MS/MS, for the simultaneous quantification of six commercially available PDE5i (avanafil, lodenafil, sildenafil, tadalafil, udenafil, and vardenafil). For this purpose, the human plasma was extracted with diethyl ether and sulfaquinoxaline was established as an internal standard. Separation was achieved using an Xbridge C18 column at 40 degrees C as the stationary phase, using water and acetonitrile as the mobile phase (both with formic acid and ammonium formate) in gradient mode. The method was validated according to the current guidelines and was found to be selective, linear (from 1 to 200 ng.mL(-1) for all drugs except for tadalafil which is from 5 to 200 ng.mL(-1)), precise, accurate, and free of residual and matrix effects. The drugs were considered stable in plasma and in solution under different conditions. The method was applied to volunteerssamples, demonstrating that the method can be used routinely and may be useful in future studies on pharmacokinetics and therapeutic monitoring.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Fully validated LC-MS/MS method for quantification of homocysteine concentrations in samples of human serum: A new approach
    Ghassabian, Sussan
    Rethwan, Nur Syazwani Ahmad
    Griffiths, Lyn
    Smith, Maree T.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 972 : 14 - 21
  • [42] Validated hydrophilic interaction LC-MS/MS method for simultaneous quantification of dacarbazine and 5-amino-4-imidazole-carboxamide in human plasma
    Liu, Yanhong
    Zhang, Weihua
    Yang, Yuhui
    [J]. TALANTA, 2008, 77 (01) : 412 - 421
  • [43] Development and validation of a sensitive LC-MS/MS assay for the quantification of nizatidine in human plasma and urine and its application to pharmacokinetic study
    Shang, De-Wei
    Wang, Zhan-Zhang
    Ni, Xiao-Jia
    Zhang, Ming
    Hu, Jin-Qing
    Qiu, Chang
    Wen, Yu-Guan
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 998 : 80 - 87
  • [44] Quantification of vancomycin in human serum by LC-MS/MS
    Koenig, Katrin
    Kobold, Uwe
    Fink, Gerhard
    Leinenbach, Andreas
    Duelffer, Thomas
    Thiele, Roland
    Zander, Johannes
    Vogeser, Michael
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (09) : 1761 - 1769
  • [45] A validated LC-MS/MS method for the rapid quantification of vilazodone in rat plasma: Application to a pharmacokinetic study
    Sui, Wenwen
    Yang, Xiaojing
    Yu, Wenhong
    Jin, Yi
    Luan, Xinyi
    Wang, Xiangjun
    Xu, Haiyan
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 98 : 228 - 234
  • [46] Validated LC-MS/MS Method for the Determination of Erlotinib in Rat Plasma
    Zhang, Hui
    Shi, Ling-min
    Chen, Wang-qiang
    Shang, Fu-mei
    Mo, Chang-hao
    Wang, Xian-min
    [J]. LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (07): : 1293 - 1297
  • [47] Detection and validated quantification of toxic alkaloids in human blood plasma - comparison of LC-APCI-MS with LC-ESI-MS/MS
    Beyer, Jochen
    Peters, Frank T.
    Kraemer, Thomas
    Maurer, Hans H.
    [J]. JOURNAL OF MASS SPECTROMETRY, 2007, 42 (05): : 621 - 633
  • [48] Development and validation of Lenalidomide in human plasma by LC-MS/MS
    Ranganathan, Premanand
    Gunasekaran, V
    Singhvi, Indrajeet
    Ansari, Mohammad Javed
    [J]. SAUDI JOURNAL OF BIOLOGICAL SCIENCES, 2019, 26 (07) : 1843 - 1847
  • [49] Determination of Lisdexamfetamine in Human Plasma by LC-MS/MS Method
    Silva, Alex A. R.
    Coelho, Lilia L. D.
    Sanchez-Luquez, Karen Y.
    Garcia, Pedro H. D.
    Boldin, Renata
    Silveira, Anne M. R.
    Antonio, Marcia A.
    Porcari, Andreia M.
    Carvalho, Patricia O.
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2025, 36 (04)
  • [50] A sensitive validated LC-MS/MS method for quantification of itraconazole in human plasma for pharmacokinetic and bioequivalence study in 24 Korean volunteers
    Rhim, Si-Youn
    Park, Jin-Hee
    Park, Yoo-Sin
    Kim, Dong-Sun
    Lee, Min-Ho
    Shaw, Leslie M.
    Kang, Ju-Seop