A validated LC-MS/MS assay for the quantification of phosphodiesterase-5 inhibitors in human plasma

被引:6
|
作者
de Souza Madeira, Camilla Regina [1 ]
Fachi, Mariana Millan [1 ]
Concentino, Victor [1 ]
Cobre, Alexandre de Fatima [1 ]
Leal Badaro Trindade, Angela Cristina [1 ]
Goncalves, Alan Guilherme [1 ]
Pontarolo, Roberto [1 ]
机构
[1] Univ Fed Parana, Dept Pharm, 632 Lothario Meissner Ave, BR-80210170 Curitiba, Parana, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2021年 / 1179卷
关键词
Phosphodiesterase-5; inhibitors; LC-MS/MS; Plasma; Validation; Therapeutic monitoring; ERECTILE DYSFUNCTION; DOUBLE-BLIND; LODENAFIL CARBONATE; ORAL-THERAPY; EFFICACY; SAFETY; TOLERABILITY; TADALAFIL; MULTICENTER; VARDENAFIL;
D O I
10.1016/j.jchromb.2021.122829
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Phosphodiesterase inhibitors (PDE5i) are considered the first line therapy for erectile dysfunction. All PDE5i available on the market are structurally related; their main differences relate to their pharmacokinetic parameters. For these treatments to be effective and safe, it is necessary that these drugs are in the appropriate doses and that they reach adequate concentrations in the plasma. For this purpose, it is essential to perform therapeutic monitoring using bioanalytical methods. In this way, the present work aimed to develop and validate a new bioanalytical method, based on LC-MS/MS, for the simultaneous quantification of six commercially available PDE5i (avanafil, lodenafil, sildenafil, tadalafil, udenafil, and vardenafil). For this purpose, the human plasma was extracted with diethyl ether and sulfaquinoxaline was established as an internal standard. Separation was achieved using an Xbridge C18 column at 40 degrees C as the stationary phase, using water and acetonitrile as the mobile phase (both with formic acid and ammonium formate) in gradient mode. The method was validated according to the current guidelines and was found to be selective, linear (from 1 to 200 ng.mL(-1) for all drugs except for tadalafil which is from 5 to 200 ng.mL(-1)), precise, accurate, and free of residual and matrix effects. The drugs were considered stable in plasma and in solution under different conditions. The method was applied to volunteerssamples, demonstrating that the method can be used routinely and may be useful in future studies on pharmacokinetics and therapeutic monitoring.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Validated LC-MS/MS Method for the Quantification of Ponatinib in Plasma: Application to Metabolic Stability
    Kadi, Adnan A.
    Darwish, Hany W.
    Attwa, Mohamed W.
    Amer, Sawsan M.
    PLOS ONE, 2016, 11 (10):
  • [22] A validated LC-MS/MS method for determination of sertaconazole nitrate in human plasma
    Wang, Yuanyuan
    Pang, Lulu
    Wu, Manying
    Ou, Ning
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (31): : 4047 - 4050
  • [23] Enantioselective quantification of chiral drugs in human plasma with LC-MS/MS
    Liu, Ke
    Zhong, Dafang
    Chen, Xiaoyan
    BIOANALYSIS, 2009, 1 (03) : 561 - 576
  • [24] Quantification of eight hematological tyrosine kinase inhibitors in both plasma and whole blood by a validated LC-MS/MS method
    Verougstraete, Nick
    Stove, Veronique
    Verstraete, Alain G.
    Stove, Christophe
    TALANTA, 2021, 226
  • [25] An improved and fully validated LC-MS/MS method for the simultaneous quantification of simvastatin and simvastatin acid in human plasma
    Apostolou, Constantinos
    Kousoulos, Constantinos
    Dotsikas, Yannis
    Soumelas, Georgios-Stefanos
    Kolocouri, Filomila
    Ziaka, Afroditi
    Loukas, Yannis L.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (04) : 771 - 779
  • [26] Validation of an LC-MS assay for the quantification of the enantiomers of Org 4428 in human plasma
    Paanakker, JE
    de Jong, J
    Thio, JMSL
    van Hal, HJM
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (06) : 981 - 989
  • [27] Sensitive and specific LC-MS assay for quantification of digoxin in human plasma and urine
    Kirby, Brian J.
    Kalhorn, Tom
    Hebert, Mary
    Easterling, Tom
    Unadkat, Jashvant D.
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (07) : 712 - 718
  • [28] Validated LC-MS/MS assay for the quantitative determination of vardenafil in human plasma and its application to a pharmacokinetic study
    Lake, Simon T.
    Altman, Phillip M.
    Vaisman, Jack
    Addison, Russell S.
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (08) : 846 - 851
  • [29] Validated LC-MS/MS assay for the quantitative determination of nalbuphine in human plasma and its application to a pharmacokinetic study
    Cai, Li-Jing
    Zhang, Jun
    Wang, Xiu-Mei
    Zhu, R. H.
    Yang, Jian
    Zhang, Qi-Zhi
    Peng, W. X.
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (12) : 1308 - 1314
  • [30] Detection and Validated Quantification of the Phosphodiesterase Type 5 Inhibitors Sildenafil, Vardenafil, Tadalafil, and 2 of Their Metabolites in Human Blood Plasma by LC-MS/MS-Application to Forensic and Therapeutic Drug Monitoring Cases
    Rust, Kristina Y.
    Wilkens, Heinrike
    Kaiser, Ralf
    Bregel, Dietmar
    Wilske, Jochen
    Kraemer, Thomas
    THERAPEUTIC DRUG MONITORING, 2012, 34 (06) : 729 - 735