Noise reduction and signal-to-noise ratio improvement of atomic magnetometers with optical gradiometer configurations

被引:37
作者
Kamada, Keigo [1 ,2 ]
Ito, Yosuke [1 ]
Ichihara, Sunao [3 ]
Mizutani, Natsuhiko [3 ]
Kobayashi, Tetsuo [1 ]
机构
[1] Kyoto Univ, Grad Sch Engn, Nishikyo Ku, Kyoto 6158510, Japan
[2] Japan Soc Promot Sci, Tsukuba, Ibaraki, Japan
[3] Canon Inc, Frontier Res Ctr, Ohta Ku, Tokyo 1468501, Japan
来源
OPTICS EXPRESS | 2015年 / 23卷 / 05期
关键词
ROOM-TEMPERATURE; FIELD; MAGNETOENCEPHALOGRAPHY; MAGNETOCARDIOGRAPHY; POTASSIUM;
D O I
10.1364/OE.23.006976
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the field of biomagnetic measurement, optically-pumped atomic magnetometers (OPAMs) have attracted significant attention. With the improvement of signal response and the reduction of sensor noise, the sensitivity of OPAMs is limited mainly by environmental magnetic noise. To reduce this magnetic noise, we developed the optical gradiometer, in which the differential output of two distinct measurement areas inside a glass cell was obtained directly via the magneto-optical rotation of one probe beam. When operating in appropriate conditions, the sensitivity was improved by the differential measurement of the optical gradiometer. In addition, measurements of the pseudo-magnetic noise and signal showed the improvement of the signal-to-noise ratio. These results demonstrate the feasibility of our optical gradiometer as an efficient method for reducing the magnetic noise. (C) 2015 Optical Society of America
引用
收藏
页码:6976 / 6987
页数:12
相关论文
共 28 条
  • [1] High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation
    Allred, JC
    Lyman, RN
    Kornack, TW
    Romalis, MV
    [J]. PHYSICAL REVIEW LETTERS, 2002, 89 (13) : 130801 - 130801
  • [2] [Anonymous], 1997, The Physics of Laser-Atom Interactions
  • [3] Theory of spin-exchange optical pumping of 3He and 129Xe
    Appelt, S
    Baranga, AB
    Erickson, CJ
    Romalis, MV
    Young, AR
    Happer, W
    [J]. PHYSICAL REVIEW A, 1998, 58 (02): : 1412 - 1439
  • [4] Dynamical mapping of the human cardiomagnetic field with a room-temperature, laser-optical sensor
    Bison, G
    Wynands, R
    Weis, A
    [J]. OPTICS EXPRESS, 2003, 11 (08): : 904 - 909
  • [5] Optical magnetometry
    Budker, Dmitry
    Romalis, Michael
    [J]. NATURE PHYSICS, 2007, 3 (04) : 227 - 234
  • [6] Baseline distance optimization for SQUID gradiometers
    Garachtchenko, A
    Matlashov, A
    Kraus, RH
    Cantor, R
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 3676 - 3679
  • [7] A high-sensitivity laser-pumped Mx magnetometer
    Groeger, S
    Bison, G
    Schenker, JL
    Wynands, R
    Weis, A
    [J]. EUROPEAN PHYSICAL JOURNAL D, 2006, 38 (02) : 239 - 247
  • [8] MAGNETOENCEPHALOGRAPHY - THEORY, INSTRUMENTATION, AND APPLICATIONS TO NONINVASIVE STUDIES OF THE WORKING HUMAN BRAIN
    HAMALAINEN, M
    HARI, R
    ILMONIEMI, RJ
    KNUUTILA, J
    LOUNASMAA, OV
    [J]. REVIEWS OF MODERN PHYSICS, 1993, 65 (02) : 413 - 497
  • [9] SPIN-EXCHANGE SHIFT AND NARROWING OF MAGNETIC-RESONANCE LINES IN OPTICALLY PUMPED ALKALI VAPORS
    HAPPER, W
    TANG, H
    [J]. PHYSICAL REVIEW LETTERS, 1973, 31 (05) : 273 - 276
  • [10] Effect of Spatial Homogeneity of Spin Polarization on Magnetic Field Response of an Optically Pumped Atomic Magnetometer Using a Hybrid Cell of K and Rb Atoms
    Ito, Yosuke
    Ohnishi, Hiroyuki
    Kamada, Keigo
    Kobayashi, Tetsuo
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2012, 48 (11) : 3715 - 3718