Chemical ionization of carboxylic acids and esters in negative mode selected ion flow tube - Mass spectrometry (SIFT-MS)

被引:4
|
作者
Ghislain, Mylene [1 ]
Reyrolle, Marine [1 ]
Sotiropoulos, Jean-Marc [1 ]
Pigot, Thierry [1 ]
Le Bechec, Mickael [1 ]
机构
[1] Univ Pau & Pays Adour, IPREM, IMT Mines Ales, CNRS,E2S UPPA, Pau, France
关键词
Selected ion flow tube - Mass spectrometry; SIFT-MS; Negative ionization; Volatile fatty acids; Esters; Modeling; VOLATILE ORGANIC-COMPOUNDS; EXHALED BREATH; AIR; VOLATOLOMICS; VOCS; SKIN;
D O I
10.1016/j.microc.2021.106609
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Selected ion flow tube - mass spectrometry (SIFT-MS) is based on chemical reactivity of analytes with reactant ions. The complete understanding of all the ion-molecule reactions is the key to the deployment of this technology for the direct and rapid analysis of VOCs in the gas phase. In the present work, we focused on direct analysis of carboxylic acids and esters, compounds involved in many biochemical processes. The ion-molecule reactions of negative precursor ions (OH-, O center dot-, O-2(center dot-), NO2- and NO3-) with 9 carboxylic acids and 21 esters were investigated in order to provide product ions and rate constants for these compounds analysis by SIFT-MS. The modelling of ion-molecule reaction paths by ab-initio calculations supported the experimental results and provided a better understanding of these gas phase ion-molecule reactions. The most common reaction mechanism with all the tested molecules is deprotonation. However, other specific reactivities, leading to the formation of anion-molecule complexes with NO2- and O-2(center dot-) in particular, are observed. Furthermore, specific fragmentations of chemical families are also noticed and confirmed with O-2(center dot-) and O center dot-. Finally, we demonstrated that the composition of the matrix (H2O, CO2) participates in the formation of secondary ions. In this work, we determined the kinetic rate constants in the nitrogen carrier gas and the detection limits of all the compounds with the eight precursor ions used by SIFT-MS, allowing accurate quantification in the gas phase at the ppb level. These results contribute to enlarge the negative ionization SIFT-MS measurements to applications where quantification of organic acids and esters are required.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Evaluation of the performance of field olfactometers by selected ion flow tube mass spectrometry
    Walgraeve, Christophe
    Van Hufffel, Katrijn
    Bruneel, Joren
    Van Langenhove, Herman
    BIOSYSTEMS ENGINEERING, 2015, 137 : 84 - 94
  • [42] SIFT-ing archaeological artifacts: Selected ion flow tube-mass spectrometry as a new tool in archaeometry
    La Nasa, Jacopo
    Nardella, Federica
    Modugno, Francesca
    Colombini, Maria Perla
    Ribechini, Erika
    Degano, Ilaria
    TALANTA, 2020, 207
  • [43] A selected ion flow tube study of the reactions of H3O+, NO+ and O2+• with seven isomers of hexanol in support of SIFT-MS
    Smith, David
    Sovova, Kristyna
    Spanel, Patrik
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2012, 319 : 25 - 30
  • [44] Ion chemistry of phthalates in selected ion flow tube mass spectrometry: isomeric effects and secondary reactions with water vapour
    Lacko, Michal
    Michalczuk, Bartosz
    Matejcik, Stefan
    Spanel, Patrik
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2020, 22 (28) : 16345 - 16352
  • [45] Selected ion flow tube, SIFT, studies of the reactions of H3O+, NO+ and O2+ with some biologically active isobaric compounds in preparation for SIFT-MS analyses
    Smith, David
    Chippendale, Thomas W. E.
    Spanel, Patrik
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 303 (2-3) : 81 - 89
  • [46] Detection and Quantification of Chemical Warfare Agent Precursors and Surrogates by Selected Ion Flow Tube Mass Spectrometry
    Francis, Gregory J.
    Milligan, Daniel B.
    McEwan, Murray J.
    ANALYTICAL CHEMISTRY, 2009, 81 (21) : 8892 - 8899
  • [47] THE VOLATILOME OF HUMAN PLURIPOTENT STEM CELLS USING SELECTED ION FLOW TUBE MASS SPECTROMETRY
    Barreto, Sara
    Forsyth, Nicholas
    Rutter, Abigail
    TISSUE ENGINEERING PART A, 2023, 29 (11-12) : 1453 - 1454
  • [48] Quantification of methylamine in the headspace of ethanol of agricultural origin by selected ion flow tube mass spectrometry
    Dryahina, K.
    Pehal, F.
    Smith, D.
    Spanel, P.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2009, 286 (01) : 1 - 6
  • [49] Quantification of methanol in the presence of ethanol by selected ion flow tube mass spectrometry
    Chambers-Bedard, Catherine
    Ross, Brian M.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2016, 22 (04) : 159 - 164
  • [50] Breath Volatile Organic Compound Profiling of Colorectal Cancer Using Selected Ion Flow-tube Mass Spectrometry
    Markar, Sheraz R.
    Chin, Sung-Tong
    Romano, Andrea
    Wiggins, Tom
    Antonowicz, Stefan
    Paraskeva, Paraskevas
    Ziprin, Paul
    Darzi, Ara
    Hanna, George B.
    ANNALS OF SURGERY, 2019, 269 (05) : 903 - 910