Chemical ionization of carboxylic acids and esters in negative mode selected ion flow tube - Mass spectrometry (SIFT-MS)

被引:4
|
作者
Ghislain, Mylene [1 ]
Reyrolle, Marine [1 ]
Sotiropoulos, Jean-Marc [1 ]
Pigot, Thierry [1 ]
Le Bechec, Mickael [1 ]
机构
[1] Univ Pau & Pays Adour, IPREM, IMT Mines Ales, CNRS,E2S UPPA, Pau, France
关键词
Selected ion flow tube - Mass spectrometry; SIFT-MS; Negative ionization; Volatile fatty acids; Esters; Modeling; VOLATILE ORGANIC-COMPOUNDS; EXHALED BREATH; AIR; VOLATOLOMICS; VOCS; SKIN;
D O I
10.1016/j.microc.2021.106609
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Selected ion flow tube - mass spectrometry (SIFT-MS) is based on chemical reactivity of analytes with reactant ions. The complete understanding of all the ion-molecule reactions is the key to the deployment of this technology for the direct and rapid analysis of VOCs in the gas phase. In the present work, we focused on direct analysis of carboxylic acids and esters, compounds involved in many biochemical processes. The ion-molecule reactions of negative precursor ions (OH-, O center dot-, O-2(center dot-), NO2- and NO3-) with 9 carboxylic acids and 21 esters were investigated in order to provide product ions and rate constants for these compounds analysis by SIFT-MS. The modelling of ion-molecule reaction paths by ab-initio calculations supported the experimental results and provided a better understanding of these gas phase ion-molecule reactions. The most common reaction mechanism with all the tested molecules is deprotonation. However, other specific reactivities, leading to the formation of anion-molecule complexes with NO2- and O-2(center dot-) in particular, are observed. Furthermore, specific fragmentations of chemical families are also noticed and confirmed with O-2(center dot-) and O center dot-. Finally, we demonstrated that the composition of the matrix (H2O, CO2) participates in the formation of secondary ions. In this work, we determined the kinetic rate constants in the nitrogen carrier gas and the detection limits of all the compounds with the eight precursor ions used by SIFT-MS, allowing accurate quantification in the gas phase at the ppb level. These results contribute to enlarge the negative ionization SIFT-MS measurements to applications where quantification of organic acids and esters are required.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Mobile selected ion flow tube mass spectrometry (SIFT-MS) devices and their use for pollution exposure monitoring in breath and ambient air-pilot study
    Storer, Malina
    Salmond, Jennifer
    Dirks, Kim N.
    Kingham, Simon
    Epton, Michael
    JOURNAL OF BREATH RESEARCH, 2014, 8 (03)
  • [32] Analysis of Factors Affecting Volatile Compound Formation in Roasted Pumpkin Seeds with Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS) and Sensory Analysis
    Bowman, T.
    Barringer, S.
    JOURNAL OF FOOD SCIENCE, 2012, 77 (01) : C51 - C60
  • [33] Ionic diffusion and mass discrimination effects in the new generation of short flow tube SIFT-MS instruments
    Smith, David
    Pysanenko, Andriy
    Spanel, Patrik
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2009, 281 (1-2) : 15 - 23
  • [34] Study of the Chemical Ionization of Organophosphate Esters in Air Using Selected Ion Flow Tube-Mass Spectrometry for Direct Analysis
    Ghislain, Mylene
    Reyrolle, Marine
    Sotiropoulos, Jean-Marc
    Pigot, Thierry
    Plaisance, Herve
    Le Bechec, Mickael
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2022, 33 (05) : 865 - 874
  • [35] Concentrations of some metabolites in the breath of healthy children aged 7-18 years measured using selected ion flow tube mass spectrometry (SIFT-MS)
    Enderby, B.
    Lenney, W.
    Brady, M.
    Emmett, C.
    Spanel, P.
    Smith, D.
    JOURNAL OF BREATH RESEARCH, 2009, 3 (03)
  • [36] Real-time detection of common microbial volatile organic compounds from medically important fungi by Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS)
    Scotter, JM
    Langford, VS
    Wilson, PF
    McEwan, MJ
    Chambers, ST
    JOURNAL OF MICROBIOLOGICAL METHODS, 2005, 63 (02) : 127 - 134
  • [37] The rapid evaluation of bacterial growth in blood cultures by selected ion flow tube-mass spectrometry (SIFT-MS) and comparison with the BacT/ALERT automated blood culture system
    Scotter, J. M.
    Allardyce, R. A.
    Langford, Vs.
    Hill, A.
    Murdoch, D. R.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2006, 65 (03) : 628 - 631
  • [38] Volatile compounds released by Nalophan; implications for selected ion flow tube mass spectrometry and other chemical ionisation mass spectrometry analytical methods
    Michalcikova, Regina Bruhova
    Dryahina, Kseniya
    Smith, David
    Spanel, Patrik
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (05)
  • [39] Application of a mobile laboratory using a selected-ion flow-tube mass spectrometer (SIFT-MS) for characterisation of volatile organic compounds and atmospheric trace gases
    Wagner, Rebecca L.
    Farren, Naomi J.
    Davison, Jack
    Young, Stuart
    Hopkins, James R.
    Lewis, Alastair C.
    Carslaw, David C.
    Shaw, Marvin D.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2021, 14 (09) : 6083 - 6100
  • [40] Account On the features, successes and challenges of selected ion flow tube mass spectrometry
    Spanel, Patrik
    Smith, David
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2013, 19 (04) : 225 - 246