Chemical ionization of carboxylic acids and esters in negative mode selected ion flow tube - Mass spectrometry (SIFT-MS)

被引:4
|
作者
Ghislain, Mylene [1 ]
Reyrolle, Marine [1 ]
Sotiropoulos, Jean-Marc [1 ]
Pigot, Thierry [1 ]
Le Bechec, Mickael [1 ]
机构
[1] Univ Pau & Pays Adour, IPREM, IMT Mines Ales, CNRS,E2S UPPA, Pau, France
关键词
Selected ion flow tube - Mass spectrometry; SIFT-MS; Negative ionization; Volatile fatty acids; Esters; Modeling; VOLATILE ORGANIC-COMPOUNDS; EXHALED BREATH; AIR; VOLATOLOMICS; VOCS; SKIN;
D O I
10.1016/j.microc.2021.106609
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Selected ion flow tube - mass spectrometry (SIFT-MS) is based on chemical reactivity of analytes with reactant ions. The complete understanding of all the ion-molecule reactions is the key to the deployment of this technology for the direct and rapid analysis of VOCs in the gas phase. In the present work, we focused on direct analysis of carboxylic acids and esters, compounds involved in many biochemical processes. The ion-molecule reactions of negative precursor ions (OH-, O center dot-, O-2(center dot-), NO2- and NO3-) with 9 carboxylic acids and 21 esters were investigated in order to provide product ions and rate constants for these compounds analysis by SIFT-MS. The modelling of ion-molecule reaction paths by ab-initio calculations supported the experimental results and provided a better understanding of these gas phase ion-molecule reactions. The most common reaction mechanism with all the tested molecules is deprotonation. However, other specific reactivities, leading to the formation of anion-molecule complexes with NO2- and O-2(center dot-) in particular, are observed. Furthermore, specific fragmentations of chemical families are also noticed and confirmed with O-2(center dot-) and O center dot-. Finally, we demonstrated that the composition of the matrix (H2O, CO2) participates in the formation of secondary ions. In this work, we determined the kinetic rate constants in the nitrogen carrier gas and the detection limits of all the compounds with the eight precursor ions used by SIFT-MS, allowing accurate quantification in the gas phase at the ppb level. These results contribute to enlarge the negative ionization SIFT-MS measurements to applications where quantification of organic acids and esters are required.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Selected-ion flow-tube mass-spectrometry (SIFT-MS) fingerprinting versus chemical profiling for geographic traceability of Moroccan Argan oils
    Kharbach, Mourad
    Kamal, Rabie
    Alaoui Mansouri, Mohammed
    Marmouzi, Ilias
    Viaene, Johan
    Cherrah, Yahia
    Alaoui, Katim
    Vercammen, Joeri
    Bouklouze, Abdelaziz
    Vander Heyden, Yvan
    FOOD CHEMISTRY, 2018, 263 : 8 - 17
  • [22] Detection of volatile metabolites produced by bacterial growth in blood culture media by selected ion flow tube mass spectrometry (SIFT-MS)
    Allardyce, RA
    Langford, VS
    Hill, AL
    Murdoch, DR
    JOURNAL OF MICROBIOLOGICAL METHODS, 2006, 65 (02) : 361 - 365
  • [23] A longitudinal study of ammonia, acetone and propanol in the exhaled breath of 30 subjects using selected ion flow tube mass spectrometry, SIFT-MS
    Turner, C
    Spanel, P
    Smith, D
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (04) : 321 - 337
  • [24] Early detection of Botrytis cinerea in strawberry fruit during quiescent infection using selected ion flow tube mass spectrometry (SIFT-MS)
    Zhao, Yijie
    De Coninck, Barbara
    Ribeiro, Bianca
    Nicolai, Bart
    Hertog, Maarten
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2023, 402
  • [25] SPME-GC-MS versus Selected Ion Flow Tube Mass Spectrometry (SIFT-MS) Analyses for the Study of Volatile Compound Generation and Oxidation Status during Dry Fermented Sausage Processing
    Olivares, Alicia
    Dryahina, Kseniya
    Navarro, Jose Luis
    Smith, David
    Spanel, Patrik
    Flores, Monica
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (05) : 1931 - 1938
  • [26] Investigation of C3-C10 aldehydes in the exhaled breath of healthy subjects using selected ion flow tube-mass spectrometry (SIFT-MS)
    Huang, Juzheng
    Kumar, Sacheen
    Hanna, George B.
    JOURNAL OF BREATH RESEARCH, 2014, 8 (03)
  • [27] Analysis of the isobaric compounds propanol, acetic acid and methyl formate in humid air and breath by selected ion flow tube mass spectrometry, SIFT-MS
    Pysanenko, Andriy
    Spanel, Patrik
    Smith, David
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2009, 285 (1-2) : 42 - 48
  • [28] Quantification of breath carbon disulphide and acetone following a single dose of disulfiram (Antabuse) using selected ion flow tube mass spectrometry (SIFT-MS)
    Bloor, Roger N.
    Spanel, Patrick
    Smith, David
    ADDICTION BIOLOGY, 2006, 11 (02) : 163 - 169
  • [29] Determining modified reaction parameters for the real-time measurement of BTEX in biogas and nitrogen using Selected Ion Flow Tube Mass Spectrometry (SIFT-MS)
    Nicholas D. C. Allen
    Mark Perkins
    Thomas Bacquart
    Jianrong Li
    Accreditation and Quality Assurance, 2019, 24 : 361 - 368
  • [30] Determining modified reaction parameters for the real-time measurement of BTEX in biogas and nitrogen using Selected Ion Flow Tube Mass Spectrometry (SIFT-MS)
    Allen, Nicholas D. C.
    Perkins, Mark
    Bacquart, Thomas
    Li, Jianrong
    ACCREDITATION AND QUALITY ASSURANCE, 2019, 24 (05) : 361 - 368