Chemical ionization of carboxylic acids and esters in negative mode selected ion flow tube - Mass spectrometry (SIFT-MS)

被引:4
|
作者
Ghislain, Mylene [1 ]
Reyrolle, Marine [1 ]
Sotiropoulos, Jean-Marc [1 ]
Pigot, Thierry [1 ]
Le Bechec, Mickael [1 ]
机构
[1] Univ Pau & Pays Adour, IPREM, IMT Mines Ales, CNRS,E2S UPPA, Pau, France
关键词
Selected ion flow tube - Mass spectrometry; SIFT-MS; Negative ionization; Volatile fatty acids; Esters; Modeling; VOLATILE ORGANIC-COMPOUNDS; EXHALED BREATH; AIR; VOLATOLOMICS; VOCS; SKIN;
D O I
10.1016/j.microc.2021.106609
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Selected ion flow tube - mass spectrometry (SIFT-MS) is based on chemical reactivity of analytes with reactant ions. The complete understanding of all the ion-molecule reactions is the key to the deployment of this technology for the direct and rapid analysis of VOCs in the gas phase. In the present work, we focused on direct analysis of carboxylic acids and esters, compounds involved in many biochemical processes. The ion-molecule reactions of negative precursor ions (OH-, O center dot-, O-2(center dot-), NO2- and NO3-) with 9 carboxylic acids and 21 esters were investigated in order to provide product ions and rate constants for these compounds analysis by SIFT-MS. The modelling of ion-molecule reaction paths by ab-initio calculations supported the experimental results and provided a better understanding of these gas phase ion-molecule reactions. The most common reaction mechanism with all the tested molecules is deprotonation. However, other specific reactivities, leading to the formation of anion-molecule complexes with NO2- and O-2(center dot-) in particular, are observed. Furthermore, specific fragmentations of chemical families are also noticed and confirmed with O-2(center dot-) and O center dot-. Finally, we demonstrated that the composition of the matrix (H2O, CO2) participates in the formation of secondary ions. In this work, we determined the kinetic rate constants in the nitrogen carrier gas and the detection limits of all the compounds with the eight precursor ions used by SIFT-MS, allowing accurate quantification in the gas phase at the ppb level. These results contribute to enlarge the negative ionization SIFT-MS measurements to applications where quantification of organic acids and esters are required.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Recent developments and applications of selected ion flow tube mass spectrometry (SIFT-MS)
    Smith, David
    Spanel, Patrik
    Demarais, Nicholas
    Langford, Vaughan S. S.
    McEwan, Murray J. J.
    MASS SPECTROMETRY REVIEWS, 2025, 44 (02) : 101 - 134
  • [2] Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis
    Smith, D
    Spanel, P
    MASS SPECTROMETRY REVIEWS, 2005, 24 (05) : 661 - 700
  • [3] Quantification of volatile metabolites in exhaled breath by selected ion flow tube mass spectrometry, SIFT-MS
    Spanel, Patrik
    Smith, David
    CLINICAL MASS SPECTROMETRY, 2020, 16 : 18 - 24
  • [4] Comprehensive odorant analysis for on-line applications using selected ion flow tube mass spectrometry (SIFT-MS)
    Langford, Vaughan S.
    Padayachee, Diandree
    McEwan, Murray J.
    Barringer, Sheryl A.
    FLAVOUR AND FRAGRANCE JOURNAL, 2019, 34 (06) : 393 - 410
  • [5] Comparison of Tomatillo and Tomato Volatile Compounds in the Headspace by Selected Ion Flow Tube Mass Spectrometry (SIFT-MS)
    Xu, Yichi
    Barringer, Sheryl
    JOURNAL OF FOOD SCIENCE, 2010, 75 (03) : C268 - C273
  • [6] Investigation of odor pollution by utilizing selected ion flow tube mass spectrometry (SIFT-MS) and principal component analysis (PCA)
    Kim, Sangcheol
    Choi, Taeryeong
    Bang, Eunok
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2024, 196 (06)
  • [7] High frequency air monitoring by selected ion flow tube-mass spectrometry (SIFT-MS): Influence of the matrix for simultaneous analysis of VOCs, CO2, ozone and water
    Ghislain, Mylene
    Costarramone, Nathalie
    Pigot, Thierry
    Reyrolle, Marine
    Lacombe, Sylvie
    Le Bechec, Mickael
    MICROCHEMICAL JOURNAL, 2020, 153
  • [8] Detection of volatile compounds produced by microbial growth in urine by selected ion flow tube mass spectrometry (SIFT-MS)
    Storer, Malina K.
    Hibbard-Melles, Kim
    Davis, Brett
    Scotter, Jenny
    JOURNAL OF MICROBIOLOGICAL METHODS, 2011, 87 (01) : 111 - 113
  • [9] Detection of adulteration in extra virgin olive oil by selected ion flow tube mass spectrometry (SIFT-MS) and chemometrics
    Ozcan-Sinir, Gulsah
    FOOD CONTROL, 2020, 118
  • [10] A longitudinal study of breath isoprene in healthy volunteers using selected ion flow tube mass spectrometry (SIFT-MS)
    Turner, C
    Spanel, P
    Smith, D
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (01) : 13 - 22