Physical and numerical phantoms for the validation of brain microstructural MRI: A cookbook

被引:62
作者
Fieremans, Els [1 ]
Lee, Hong-Hsi [1 ]
机构
[1] NYU, Sch Med, Dept Radiol, Ctr Biomed Imaging, New York, NY USA
关键词
Numerical phantoms; Hardware phantoms; Validation; Microstructure; Brain; APPARENT DIFFUSION-COEFFICIENT; NMR RELAXATION-TIMES; MAGNETIC-RESONANCE; SELF-DIFFUSION; WHITE-MATTER; SPIN-ECHO; RESTRICTED DIFFUSION; FIELD-GRADIENT; IN-VIVO; WATER DIFFUSION;
D O I
10.1016/j.neuroimage.2018.06.046
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Phantoms, both numerical (software) and physical (hardware), can serve as a gold standard for the validation of MRI methods probing the brain microstructure. This review aims to provide guidelines on how to build, implement, or choose the right phantom for a particular application, along with an overview of the current state-of-the-art of phantoms dedicated to study brain microstructure with MRI. For physical phantoms, we discuss the essential requirements and relevant characteristics of both the (NMR visible) liquid and (NMR invisible) phantom materials that induce relevant microstructural features detectable via MRI, based on diffusion, intra-voxel incoherent motion, magnetization transfer or magnetic susceptibility weighted contrast. In particular, for diffusion MRI, many useful phantoms have been proposed, ranging from simple liquids to advanced biomimetic phantoms consisting of hollow or plain microfibers and capillaries. For numerical phantoms, the focus is on Monte Carlo simulations of random walk, for which the basic principles, along with useful criteria to check and potential pitfalls are reviewed, in addition to a literature overview highlighting recent advances. While many phantoms exist already, the current review aims to stimulate further research in the field and to address remaining needs.
引用
收藏
页码:39 / 61
页数:23
相关论文
共 266 条
  • [1] Dairy cream as a phantom material for biexponential diffusion decay
    Ababneh, Z
    Haque, M
    Maier, SE
    Mulkern, RV
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 17 (02) : 95 - 100
  • [2] FIBER COMPOSITION OF THE HUMAN CORPUS-CALLOSUM
    ABOITIZ, F
    SCHEIBEL, AB
    FISHER, RS
    ZAIDEL, E
    [J]. BRAIN RESEARCH, 1992, 598 (1-2) : 143 - 153
  • [3] Orientationally invariant indices of axon diameter and density from diffusion MRI
    Alexander, Daniel C.
    Hubbard, Penny L.
    Hall, Matt G.
    Moore, Elizabeth A.
    Ptito, Maurice
    Parker, Geoff J. M.
    Dyrby, Tim B.
    [J]. NEUROIMAGE, 2010, 52 (04) : 1374 - 1389
  • [4] [Anonymous], 2013, Surface Science Techniques, DOI DOI 10.1007/978-3-642-34243-1_1
  • [5] [Anonymous], 2010, Diffusion MRI, DOI 10.1093/med/9780195369779.003.0010
  • [6] Direct laser writing
    Anscombe, Nadya
    [J]. NATURE PHOTONICS, 2010, 4 (01) : 22 - 23
  • [7] Filter-exchange PGSE NMR determination of cell membrane permeability
    Aslund, Ingrid
    Nowacka, Agnieszka
    Nilsson, Markus
    Topgaard, Daniel
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2009, 200 (02) : 291 - 295
  • [8] Determination of the self-diffusion coefficient of intracellular water using PGSE NMR with variable gradient pulse length
    Aslund, Ingrid
    Topgaard, Daniel
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2009, 201 (02) : 250 - 254
  • [9] The effect of rotational angle and experimental parameters on the diffraction patterns and micro-structural information obtained from q-space diffusion NMR:: implication for diffusion in white matter fibers
    Avram, L
    Assaf, Y
    Cohen, Y
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2004, 169 (01) : 30 - 38
  • [10] Microstructural analysis of foam by use of NMR R2 dispersion
    Baete, S. H.
    De Deene, Y.
    Masschaele, B.
    De Neve, W.
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2008, 193 (02) : 286 - 296