Frequency domain based control design for an HVdc converter connected to a weak AC network

被引:20
|
作者
O'Reilly, J [1 ]
Wood, AR
Osauskas, CM
机构
[1] Univ Glasgow, Dept Elect Engn, Glasgow G12 8LT, Lanark, Scotland
[2] Univ Canterbury, Dept Elect & Elect Engn, Christchurch 1, New Zealand
关键词
control; FACTS; frequency domain; HVdc;
D O I
10.1109/TPWRD.2003.813638
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A small-signal frequency domain model of an HVdc system connected to a weak ac network is used for an operating point-based rectifier direct current control design. The frequency response of the open-loop system is systematically shaped, clearly showing the controller design tradeoffs involved in achieving the objectives of damped system oscillations and disturbance rejection. The performance of the controller is verified by time-domain simulation of the CIGRE Benchmark HVdc test system. This validates the use of small-signal frequency response models for HVdc system control analysis and design. The further developments necessary for a practical controller for large signal excursions are discussed.
引用
收藏
页码:1028 / 1033
页数:6
相关论文
共 50 条
  • [31] ADVANCED SCHEME FOR AC VOLTAGE CONTROL AT HVDC CONVERTER TERMINALS
    HAMMAD, A
    SADEK, K
    KOELSCH, H
    GUETH, G
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (03): : 697 - 703
  • [32] Stability Analysis and Control Parameter Optimization for Hybrid Modular Multilevel Converter Connected to Weak AC System
    Lu X.
    Xiang W.
    Lin W.
    Wen J.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (16): : 70 - 78
  • [33] A novel supplementary frequency-based dual damping control for VSC-HVDC system under weak AC grid
    Wang, Ye
    Guo, Chunyi
    Zhao, Chengyong
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 103 : 212 - 223
  • [34] Analytical Calculation Method of Outer Loop Controller Parameters of HVDC Converter Station Connected to Weak AC Grid and Analysis of Limiting Factors
    Li Y.
    Zhao W.
    He Z.
    Yang J.
    Zhou J.
    Xu J.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (24): : 9682 - 9695
  • [35] Fuzzy logic based control algorithm for DSTATCOM connected to weak AC grid
    Chawda, Gajendra Singh
    Shaik, Abdul Gafoor
    2018 2ND INTERNATIONAL CONFERENCE ON POWER, ENERGY AND ENVIRONMENT: TOWARDS SMART TECHNOLOGY (ICEPE), 2018,
  • [36] New HVDC interaction between AC network and HVDC shunt reactor on jeju converter station
    Kim, Chan-Ki
    Kwon, Young-Hun
    Jang, Gilsoo
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 3634 - 3637
  • [37] Study on Mechanism of STATCOM Improving the Transmission Capability of HVDC Connected to Weak AC System
    Yang J.
    Hong C.
    Zhou B.
    Li H.
    Zhang Y.
    Zhang F.
    Li J.
    Sun P.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (17): : 5005 - 5014
  • [38] Frequency Stability Control Research of AC Grid Based on HVDC Transmission System
    Sun K.
    Li K.
    Lakshmi S.
    Yilu L.
    Pan J.
    Sun H.
    1600, Chinese Society for Electrical Engineering (40): : 723 - 730
  • [39] Recovery characteristics of new-type HVDC connected to AC system with weak strength
    Li, Ji
    Luo, Long-Fu
    Xu, Jia-Zhu
    Li, Yong
    Zhang, Jie
    Liu, Fu-Sheng
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (10): : 137 - 141
  • [40] Effect of the DC control on recovery from commutation failures in an HVDC inverter feeding a weak AC network
    Khatir, Mohamed
    Zidi, Sid-Ahmed
    Hadjeri, Samir
    Fellah, Mohammed-Karim
    Dahou, Omar
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2007, 58 (04): : 200 - 206