Uterine artery blood flow and microvessel density by vaginal color Doppler ultrasonography in embryo implantation failure

被引:20
作者
Li, Zhen [1 ]
Wang, Xingling [1 ]
Guan, Yichun [1 ]
Yu, Xiaona [1 ]
Liu, Jing [1 ]
Zhang, Zhan [2 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 3, Reprod Ctr, Zhengzhou 450052, Henan, Peoples R China
[2] Shangqiu Med Coll, 7 Kangfuqian St, Shangqiu 476100, Henan, Peoples R China
关键词
repeated implantation failure; uterine artery blood flow; vaginal color Doppler ultrasonography; microvessel density; POLYCYSTIC-OVARY-SYNDROME; IN-VITRO FERTILIZATION; ENDOMETRIAL; ULTRASOUND; RECEPTIVITY; INFERTILITY; RESISTANCE; SECRETION; CARCINOMA; PREGNANCY;
D O I
10.3892/etm.2017.5114
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The purpose of this study was to investigate the clinical application of uterine artery blood flow parameters by vaginal color Doppler ultrasonography in patients with repeated embryo implantation failure and to examine the correlation between uterine artery blood flow parameters and microvessel density (MVD). We monitored the outcomes of in vitro fertilization and embryo transfer in eighty patients. We divided the patients into two groups: Pregnancy (successful pregnancy, n=50) and repeated implantation failure (more than two failures of in vitro fertilization-embryo transfer, n=30). The patients were subjected to vaginal color Doppler ultrasonography to measure endometrial thickness, peak systolic velocity/end diastolic velocity (S/D), pulsatility index (PI), resistance index (RI), and other uterine artery blood flow parameters. We found no significant differences in endometrial thickness (human chorionic gonadotropin endometrial thickness) and uterine artery blood flow parameters (S/D, PI) between the two groups. The RI value of endometrial blood flow was significantly higher in the repeated implantation failure group than that in pregnancy group. The endometrium MVD in the repeated implantation failure group was significantly lower than that of the pregnancy group. Spearman correlation analysis showed that S/D value of uterine artery blood flow in repeated implantation failure group was not correlated with MVD or uterine artery blood flow PI, but was positively correlated with RI. Endometrium MVD in patients with repeated implantation failure was significantly lower than that in patients with successful pregnancy during the implantation window. We also found a significant difference in uterine artery blood flow RI between the two groups. The uterine artery blood flow RI in patients with repeated implantation failure was positively correlated with MVD, which has clinical significance in predicting the outcome of embryo transfer.
引用
收藏
页码:4797 / 4800
页数:4
相关论文
共 49 条
  • [21] Accuracy of subjective evaluation of luteal blood flow by color Doppler ultrasonography for early diagnosis of pregnancy in Egyptian buffalo
    Samir, Haney
    Kandiel, Mohamed M. M.
    ANIMAL REPRODUCTION SCIENCE, 2019, 208
  • [22] Doppler indices of middle uterine artery as a tool for predicting the fetal status in cattle with uterine torsion and the recovery of uterine blood flow subsequent to detorsion
    Singh, Navdeep
    Ghuman, Sarvpreet Singh
    Gandotra, Vinod Kumar
    INDIAN JOURNAL OF ANIMAL SCIENCES, 2019, 89 (05) : 491 - 494
  • [23] BLOOD-FLOW CHANGES IN UTERINE AND OVARIAN VASCULATURE, AND PREDICTIVE VALUE OF TRANSVAGINAL PULSED COLOR DOPPLER ULTRASONOGRAPHY IN AN IN-VITRO FERTILIZATION PROGRAM
    TEKAY, A
    MARTIKAINEN, H
    JOUPPILA, P
    HUMAN REPRODUCTION, 1995, 10 (03) : 688 - 693
  • [24] Effect of varicocele on testicular artery blood flow in men -: Color Doppler investigation
    Tarhan, S
    Gümüs, B
    Gündüz, I
    Ayyildiz, V
    Göktan, C
    SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 2003, 37 (01): : 38 - 42
  • [25] Assessment of uterine artery blood flow on the day of human chorionic gonadotropin administration by transvaginal color Doppler ultrasound in an in vitro fertilization program
    Zaidi, J
    Pittrof, R
    Shaker, A
    KyeiMensah, A
    Campbell, S
    Tan, SL
    FERTILITY AND STERILITY, 1996, 65 (02) : 377 - 381
  • [26] Developmental changes in spiral artery blood flow in the human placenta observed with colour Doppler ultrasonography
    Collins, S. L.
    Stevenson, G. N.
    Noble, J. A.
    Impey, L.
    PLACENTA, 2012, 33 (10) : 782 - 787
  • [27] Correlation of Prostatic Artery Blood Flow Assessed by Doppler Ultrasonography with Semen Characteristics in Beagle Dogs
    Luno, Victoria
    Servian, Marina
    Martinez, Felisa
    Borobia, Maria
    Gonzalez, Noelia
    Gil, Lydia
    ANIMALS, 2020, 10 (11): : 1 - 7
  • [28] Association of angiotensin II and receptors in peri-implantation endometrium with microvessel density and pregnancy outcomes of women with recurrent implantation failure after embryo transfer
    Qi, Ruofan
    Zhang, Tao
    Zhang, Yingying
    Chung, Jacqueline Pui Wah
    Yang, Wen-Jui
    Wang, Chi Chiu
    FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [29] Effect of of seasonality on testicular blood flow as determined by color Doppler ultrasonography and hormonal profiles in Shiba goats
    Samir, Haney
    Nyametease, Paul
    Nagaoka, Kentaro
    Watanabe, Gen
    ANIMAL REPRODUCTION SCIENCE, 2018, 197 : 185 - 192
  • [30] Association between uterine artery Doppler blood flow changes and arterial wall elasticity in pregnant women
    von Wowern, Emma
    Andersson, Jakob
    Skarping, Ida Dalene
    Howie, Maria Teresa
    Olofsson, Per
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2017, 30 (19) : 2309 - 2314