Effect of detector element size on signal detectability in digital mammography

被引:6
|
作者
Burgess, AE [1 ]
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
breast structure; detector element size; digital mammography; lesion detectability; microcalcifications; SNR;
D O I
10.1117/12.593770
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this work was to evaluate the effect of detector element size on detection and discrimination of small objects in digital mammograms in the presence of quantum noise, stochastic breast structure {P (f) = K/f(3))} and system (electronic) noise. Theoretical analysis was done using the Fourier domain approximation of Albert and Maidment (Medical Physics, Vol. 27, pp 2417-2434, 2000), including averaging over random but known signal locations and aliasing. Realistic CsI-based indirect detection system operating parameters were used with 4 detector element sizes (25, 50, 75 and 100 microns). Detailed results depended on selected input exposure and system noise level (10 mR and 100 photons/del equivalent photon input were used). Results will be described using size thresholds based on human decision performance estimates - typical threshold SNRs were about 6 to 7 at 95% decision accuracy. The selected tasks and approximate threshold sizes were: searching for a microcalcification in a 1 cm(2) cluster (140 microns), two-alternative forced-choice microcalcification discrimination of shape (220 microns) and edge gradient (290 microns), and searching for a spiculation (cylinder model) around the perimeter of a known mass. MC task threshold variations with del size were small (usually less than 5% variation). Spiculation thresholds depended on length and surrounding tissue composition - del size and system noise had little effect. For 15 mm spiculations, the threshold diameters were about 0.5 nim in fatty tissue and 1.3 mm in 50% glandular tissue.
引用
收藏
页码:232 / 242
页数:11
相关论文
共 50 条
  • [41] Image quality of a prototype direct conversion detector for digital mammography
    Mainprize, JG
    Ford, NL
    Yin, S
    Tümer, T
    Yaffe, MJ
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 398 - 406
  • [42] Imaging characteristics of a CsI:Tl slot detector for digital mammography
    Jing, Z
    Huda, W
    Walker, JK
    RADIOLOGY, 1997, 205 : 101 - 101
  • [43] Analysis of the detective quantum efficiency of a developmental detector for digital mammography
    Williams, MB
    Simoni, PU
    Smilowitz, L
    Stanton, M
    Phillips, W
    Stewart, A
    MEDICAL PHYSICS, 1999, 26 (11) : 2273 - 2285
  • [44] A novel digital mammography detector concept based on microchannel plates
    Shikhaliev, PM
    Xu, T
    Le, H
    Molloi, S
    MEDICAL PHYSICS, 2003, 30 (06) : 1455 - 1456
  • [45] Full-field digital mammography: A phantom study for the detectability of simulated microcalcifications.
    Obenauer, S
    Hermann, KP
    Schorn, C
    Funke, M
    Fischer, U
    Grabbe, E
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (07): : 646 - 650
  • [46] Digital mammography detects smaller lesion size and contrast than conventional mammography
    Levy, LD
    Dana, A
    Martin, B
    Meyer, D
    Teman, G
    Benali, K
    RADIOLOGY, 2001, 221 : 284 - 284
  • [47] Validation of a statistical method for low contrast detectability as a simple tool for QC in digital mammography
    Villa, Raffaele
    Oberhofer, Nadia
    Paruccini, Nicoletta
    15TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI2020), 2020, 11513
  • [48] Full-field digital mammography: An anthropomorphic phantom study for the detectability of simulated microcalcifications
    Obenauer, S
    Schorn, C
    Hermann, K
    Funke, M
    Fischer, U
    Grabbe, EH
    RADIOLOGY, 2000, 217 : 200 - 200
  • [49] Computation of realistic virtual phantom images for an objective lesion detectability assessment in digital mammography
    Perez-Ponce, Hector
    Daul, Christian
    Wolf, Didier
    Noel, Alain
    MEDICAL ENGINEERING & PHYSICS, 2011, 33 (10) : 1276 - 1286
  • [50] Signal detectability in diffusive media using phased arrays in conjunction with detector arrays
    Kang, Dongyel
    Kupinski, Matthew A.
    OPTICS EXPRESS, 2011, 19 (13): : 12261 - 12274