Surface characterization of anodized zirconium for biomedical applications

被引:54
作者
Gomez Sanchez, A. [1 ]
Schreiner, W. [2 ]
Duffo, G. [3 ,4 ]
Cere, S. [1 ]
机构
[1] Univ Nacl Mar del Plata CONICET, Div Corros INTEMA, RA-7600 Mar Del Plata, Buenos Aires, Argentina
[2] UFPR, Dept Fis, LSI LANSEN, Curitiba, Parana, Brazil
[3] Comis Nacl Energia Atom CONICET, Dept Mat, RA-1650 Buenos Aires, DF, Argentina
[4] Univ Nacl Gral San Martin, RA-1650 Buenos Aires, DF, Argentina
关键词
Zirconium; Permanent implants; Surface film; COMMERCIALLY PURE TITANIUM; OXIDE-FILMS; METALLIC BIOMATERIALS; NANOSCALE TOPOGRAPHY; OXIDIZED ZIRCONIUM; IN-VITRO; OXIDATION; IMPLANT; BONE; SPECTROSCOPY;
D O I
10.1016/j.apsusc.2011.02.005
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Mechanical properties and corrosion resistance of zirconium make this material suitable for biomedical implants. Its good in vivo performance is mainly due to the presence of a protective oxide layer that minimizes corrosion rate, diminishes the amount of metallic ions released to the biological media and facilitates the osseointegration process. Since the implant surface is the region in contact with living tissues, the characteristics of the surface film are of great interest. Surface modification is a route to enhance both biocompatibility and corrosion resistance of permanent implant materials. Anodizing is presented as an interesting process to modify metal surfaces with good reproducibility and independence of the geometry. In this work the surface of zirconium before and after anodizing in 1 mol/L phosphoric acid solution at a fixed potential between 3 and 30 V, was characterized by means of several surface techniques. It was found that during anodization the surface oxide grows with an inhomogeneous coverage on zirconium surface, modifying the topography. The incorporation of P from the electrolyte to the surface oxide during the anodizing process changes the surface chemistry. After 30 days of immersion in Simulated Body Fluid (SBF) solution, Ca-P rich compounds were present on anodized zirconium. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:6397 / 6405
页数:9
相关论文
共 59 条
[1]   Corrosion behaviour of commercially pure titanium shot blasted with different materials and sizes of shot particles for dental implant applications [J].
Aparicio, C ;
Gil, FJ ;
Fonseca, C ;
Barbosa, M ;
Planell, JA .
BIOMATERIALS, 2003, 24 (02) :263-273
[2]   On Raman spectroscopy of zirconium oxide films [J].
Barberis, P ;
MerleMejean, T ;
Quintard, P .
JOURNAL OF NUCLEAR MATERIALS, 1997, 246 (2-3) :232-243
[3]   AC IMPEDANCE SPECTROSCOPY OF THE ANODIC FILM ON ZIRCONIUM IN NEUTRAL SOLUTION [J].
BARDWELL, JA ;
MCKUBRE, MCH .
ELECTROCHIMICA ACTA, 1991, 36 (3-4) :647-653
[4]   Nano-scale study of the nucleation and growth of calcium phosphate coating on titanium implants [J].
Barrere, F ;
Snel, MME ;
van Blitterswijk, CA ;
de Groot, K ;
Layrolle, P .
BIOMATERIALS, 2004, 25 (14) :2901-2910
[5]   Can bioactivity be tested in vitro with SBF solution? [J].
Bohner, Marc ;
Lemaitre, Jacques .
BIOMATERIALS, 2009, 30 (12) :2175-2179
[6]  
Cabrini R L, 1993, Implant Dent, V2, P264
[7]   Influence of the anodic oxidation on the physicochemical properties of the Ti6Al4V ELI alloy [J].
Chrzanowski, W ;
Szewczenko, J ;
Tyrlik-Held, J ;
Marciniak, J ;
Zak, J .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2005, 162 :163-168
[8]  
Costa O R, 1994, Acta Odontol Latinoam, V8, P17
[10]   Bone bonding at natural and biomaterial surfaces [J].
Davies, John E. .