On-demand droplet spotter for preparing pico- to femtoliter droplets on surfaces

被引:75
作者
Yogi, O
Kawakami, T
Yamauchi, M
Ye, JY
Ishikawa, M
机构
[1] ATP, JRCAT, Tsukuba, Ibaraki 3050046, Japan
[2] Hamamatsu Photon KK Cent Res Lab, Hamakita, Shizuoka 4340041, Japan
关键词
D O I
10.1021/ac0012039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A droplet spotter for on-demand generation of pico- to femtoliter droplets was developed to meet the requirement for high-density spotting of chemicals on a surface, Our droplet spotter involves applying a similar to 1000-V and similar to 10ms pulse voltage to the tip of a capillary tube (o.d. similar to 18 mum; i.d. similar to 11 pm) supplied with water or a dye solution. The capability of the spotter was demonstrated by preparing a microarray of dye molecules. The microarray was prepared by spotting similar to 30-fL droplets of a dye solution on a surface at the density of one spot per 20 x 20 mum(2).
引用
收藏
页码:1896 / 1902
页数:7
相关论文
共 20 条
  • [1] Barnes MD, 1999, CYTOMETRY, V36, P169, DOI 10.1002/(SICI)1097-0320(19990701)36:3<169::AID-CYTO4>3.0.CO
  • [2] 2-I
  • [3] DETECTION OF SINGLE RHODAMINE-6G MOLECULES IN LEVITATED MICRODROPLETS
    BARNES, MD
    NG, KC
    WHITTEN, WB
    RAMSEY, JM
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (17) : 2360 - 2365
  • [4] AN IMPROVED UNIFORM-SIZE-DROPLET GENERATOR
    CHILDERS, AG
    HIEFTJE, GM
    [J]. APPLIED SPECTROSCOPY, 1986, 40 (05) : 688 - 691
  • [5] ELECTROHYDRODYNAMIC SPRAYING FUNCTIONING MODES - A CRITICAL-REVIEW
    CLOUPEAU, M
    PRUNETFOCH, B
    [J]. JOURNAL OF AEROSOL SCIENCE, 1994, 25 (06) : 1021 - 1036
  • [6] MONODISPERSE DRIED MICROPARTICULATE INJECTOR FOR ANALYTICAL INSTRUMENTATION
    FRENCH, JB
    ETKIN, B
    JONG, R
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (05) : 685 - 691
  • [7] System for preparing microhybridization arrays on glass slides
    Graves, DJ
    Su, HJ
    McKenzie, SE
    Surrey, S
    Fortina, P
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (23) : 5085 - 5092
  • [8] DROPLET ELECTROSPRAY MASS-SPECTROMETRY
    HAGER, DB
    DOVICHI, NJ
    KLASSEN, J
    KEBARLE, P
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (22) : 3944 - 3949
  • [9] BEHAVIOR OF MICROSCOPIC LIQUID DROPLETS NEAR A STRONG ELECTROSTATIC-FIELD - DROPLET ELECTROSPRAY
    HAGER, DB
    DOVICHI, NJ
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (09) : 1593 - 1594
  • [10] Handling of picoliter liquid samples in a poly(dimethylsiloxane)-based microfluidic device
    Hosokawa, K
    Fujii, T
    Endo, I
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (20) : 4781 - 4785