Assessment of the prevalence and length of the anterior and caudal loops of the mental nerve as anatomical variants of exiting the mandible at the mental foramen using cone-beam computed tomography: a systematic review and meta-analysis

被引:5
作者
Hui, Liuling [1 ]
Hung, Kuo Feng [1 ]
Bornstein, Michael Marc [2 ,3 ]
Leung, Yiu Yan [1 ,4 ]
机构
[1] Univ Hong Kong, Fac Dent, Oral & Maxillofacial Surg, Hong Kong, Peoples R China
[2] Univ Hong Kong, Fac Dent Appl Oral Sci & Community Dent Care, Oral & Maxillofacial Radiol, Hong Kong, Peoples R China
[3] Univ Basel, Univ Ctr Dent Med Basel UZB, Dept Oral Hlth & Med, Basel, Switzerland
[4] Prince Philip Dent Hosp, Sai Ying Pun, 34 Hosp Rd, Hong Kong, Peoples R China
关键词
Cone-bean computed tomography; Mental foramen; Mental nerve; Anterior loop; Caudal loop; INFERIOR ALVEOLAR NERVE; DENTAL IMPLANT PLACEMENT; SAFE ZONE; RECOMMENDATION;
D O I
10.1007/s00784-022-04656-x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives This systematic review aimed to identify the studies that performed cone-beam computed tomography analysis of the prevalence and length of the anterior loop (AL) and caudal loop (CL) of the mental nerve. Materials and methods An electronic database search was performed across PubMed, EMBASE, Web of Science, Scopus, the Cochrane library, and Google Scholar. Original studies reporting the frequency and length of the AL and CL were selected. Qualitative synthesis and meta-analysis were then conducted to assess the prevalence and length of the AL and CL and their associations with age, gender, sides, and dentition status. Results A total of 21 studies were included in this review. The pooled prevalence of the AL (95% confidence interval) of the mental nerve at the patient and side level was 51% (31-71%) and 53% (37-69%) while the mean anterior loop length was 2.08 (1.46-2.70) mm. The pooled prevalence of the CL and mean caudal loop length were 100% and 4.73 (3.44-6.01) mm. No significant associations were found between the prevalence and length of the AL and CL and age, gender, sides, and dentition status. Conclusions Overall, the pooled prevalence and mean length of AL of the mental nerve varied among different populations while CL seems to be a constant anatomical landmark with a longer CL than AL.
引用
收藏
页码:6423 / 6441
页数:19
相关论文
共 37 条
  • [1] The anterior loop of the inferior alveolar nerve: prevalence, measurement of its length and a recommendation for interforaminal implant installation based on cone beam CT imaging
    Apostolakis, Dimitrios
    Brown, Jackie E.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (09) : 1022 - 1030
  • [2] How to perform a meta-analysis with R: a practical tutorial
    Balduzzi, Sara
    Ruecker, Gerta
    Schwarzer, Guido
    [J]. EVIDENCE-BASED MENTAL HEALTH, 2019, 22 (04) : 153 - 160
  • [3] Dental Implant Placement Investigation: Is the Anterior Loop of the Mental Nerve Clinically Relevant?
    Benninger, Brion
    Miller, Dan
    Maharathi, Anand
    Carter, Winthrop
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (01) : 182 - 185
  • [4] Relationship between the position of the mental foramen and the anterior loop of the inferior alveolar nerve as determined by cone beam computed tomography combined with mimics
    Department of Implant Dentistry, Stomatology Hospital, Guangxi Medical University, 10 Shuangyong Rd, Nanning, Guangxi
    530021, China
    不详
    不详
    [J]. J. Comput. Assisted Tomogr., 1 (86-93): : 86 - 93
  • [5] Cochrane Collaboration, 2021, COCHRANE HDB SYSTEMA
  • [6] Cribari-Neto F, 2010, J STAT SOFTW, V34, P1
  • [7] Assessment of variations of the mandibular canal through cone beam computed tomography
    de Oliveira-Santos, Christiano
    Couto Souza, Paulo Henrique
    Berti-Couto, Soraya de Azambuja
    Stinkens, Lien
    Moyaert, Kristin
    Fischer Rubira-Bullen, Izabel Regina
    Jacobs, Reinhilde
    [J]. CLINICAL ORAL INVESTIGATIONS, 2012, 16 (02) : 387 - 393
  • [8] Cone beam computed tomography evaluation of mandibular canal anterior loop morphology and volume in a group of Turkish patients
    Eren, Hakan
    Orhan, Kaan
    Bagis, Nilsun
    Nalcaci, Rana
    Misirli, Melis
    Hincal, Evren
    [J]. BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2016, 30 (02) : 346 - 353
  • [9] The inferior alveolar nerve's loop at the mental foramen and its implications for surgery
    Filo, Katharina
    Schneider, Thomas
    Locher, Michael C.
    Kruse, Astrid L.
    Luebbers, Heinz-Theo
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2014, 145 (03) : 260 - 269
  • [10] Accuracy of linear measurements on CBCT images related to presurgical implant treatment planning: A systematic review
    Fokas, George
    Vaughn, Vida M.
    Scarfe, William C.
    Bornstein, Michael M.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 : 393 - 415