Diagnostic accuracy of point-of-care ultrasound (PoCUS) for shoulder dislocations and reductions in the emergency department: a diagnostic randomised control trial (RCT)

被引:7
|
作者
Biancardi, Mark Anthony Attard [1 ]
Jarman, Robert David [2 ]
Cardona, Tania [3 ]
机构
[1] Mater Dei Hosp, Emergency Dept, MSD-2090 Msida, Malta
[2] Royal Victoria Infirm, Emergency Med, Newcastle Upon Tyne, Tyne & Wear, England
[3] Mater Dei Hosp, Dept Policy Hlth Hlth Informat & Res, Msida, Malta
关键词
SAMPLE-SIZE; MANAGEMENT; ULTRASONOGRAPHY; RADIOGRAPHS;
D O I
10.1136/emermed-2020-210947
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Following blunt trauma, diagnosis of shoulder dislocation based on physical examination alone is difficult due to possible concurrent proximal humeral fractures. X-rays are therefore used to confirm diagnosis. Results from recent observational studies comparing diagnostic accuracy of point-of-care ultrasound (PoCUS) with X-rays for shoulder dislocation have been encouraging. The aim of this study was to determine whether PoCUS improves diagnostic accuracy when used with physical examination for the diagnosis of shoulder dislocation, proximal humeral fracture and ascertaining successful reduction in the ED. Methods A prospective, single-centre, open, parallel randomised control study over a 6-month period was used to answer the research question and test the null hypothesis. Consecutive eligible adult patients attending the ED of Mater Dei Hospital in Malta were randomised to either the control (C) (physical examination only) or experimental group (E) (physical examination and a two-point PoCUS scan). The study objectives were to measure diagnostic accuracy for both examinations for detecting shoulder dislocation, any associated proximal humeral fractures and confirming reduction. X-rays were used as reference standard for both groups. Results 1206 patients were enrolled in this study (C n=600, E n=606). 290 dislocations (C n=132 and E n=158), 332 proximal humeral fractures (C n=154 and E n=178) and 278 reductions (C n=130 and E n=148) were analysed. A statistically significant difference (p<0.001) was found between the two groups for diagnostic accuracy in shoulder dislocation (C=65%, likelihood ratio (LR)+=2.03 and LR-=0.35 and E=100%, LR+=infinity and LR-=0), proximal humeral fractures (C=45.7%, LR+=1.23 and LR-=0.52 and E=98.3%, LR+=103.9 and LR-=0.03) and reduction (C=68.7%, E=100%). The null hypothesis for this study was thus rejected. Conclusions The addition of PoCUS to a physical examination significantly improves diagnostic accuracy for dislocations, proximal humeral fractures and reduction confirmation.
引用
收藏
页码:655 / U139
页数:7
相关论文
共 50 条
  • [11] The diagnostic accuracy of point-of-care ultrasound parameters for airway assessment in patients undergoing intubation in emergency department-an observational study
    Pillai, Aadya
    Arora, Poonam
    Kabi, Ankita
    Chauhan, Udit
    Asokan, Reshma
    Akhil, P.
    Shankar, Takshak
    Lalneiruol, D. J.
    Baid, Himanshi
    Chawang, Hannah
    INTERNATIONAL JOURNAL OF EMERGENCY MEDICINE, 2024, 17 (01)
  • [12] The Accuracy of Point-of-Care Ultrasound (POCUS) in Acute Gallbladder Disease
    Dumbrava, Bogdan-Daniel
    Bass, Gary Alan
    Jumean, Amro
    Birido, Nuha
    Corbally, Martin
    Pereira, Jorge
    Biloslavo, Alan
    Zago, Mauro
    Walsh, Thomas Noel
    DIAGNOSTICS, 2023, 13 (07)
  • [13] Diagnostic accuracy of point-of-care ultrasound of the posterior fatpad in elbow fractures
    Haak, Svenja L.
    van der Veen, Thea
    Stolmeijer, Renate
    Boendermaker, Annemieke E.
    van der Kolk, Brigitta Y. M.
    ter Maaten, Jan C.
    Ter Avest, Ewoud
    Lameijer, Heleen
    EMERGENCY MEDICINE JOURNAL, 2025,
  • [14] Diagnostic point-of-care ultrasound (POCUS) for gastrointestinal pathology: state of the art from basics to advanced
    Abu-Zidan, Fikri M.
    Cevik, Arif Alper
    WORLD JOURNAL OF EMERGENCY SURGERY, 2018, 13
  • [15] 'Water challenge' to improve diagnostic accuracy in gastric point-of-care ultrasound
    Sidhu, N. S.
    ANAESTHESIA REPORTS, 2022, 10 (02)
  • [16] A point-of-care thoracic ultrasound protocol for hospital medical emergency teams (METUS) improves diagnostic accuracy
    M.J, Blans
    E, Bousie
    van der J.G, Hoeven
    F.H, Bosch
    ULTRASOUND JOURNAL, 2021, 13 (01)
  • [17] The Accuracy of Point-of-Care Ultrasound in Detecting Small Bowel Obstruction in Emergency Department
    Pourmand, A.
    Dimbil, U.
    Drake, A.
    Shokoohi, H.
    EMERGENCY MEDICINE INTERNATIONAL, 2018, 2018
  • [18] Improving Point-of-Care Ultrasound Documentation and Billing Accuracy in a Pediatric Emergency Department
    Ng, Carrie
    Payne, Asha S.
    Patel, Amit K.
    Thomas-Mohtat, Rosemary
    Maxwell, Angela
    Abo, Alyssa
    PEDIATRIC QUALITY & SAFETY, 2020, 5 (04) : E315
  • [19] Diagnostic accuracy of point-of-care ultrasound for catheter-related thrombosis in children
    Li, Simon
    Silva, Cicero T.
    Brudnicki, Adele R.
    Baker, Kenneth E.
    Tala, Joana A.
    Pinto, Matthew G.
    Polikoff, Lee A.
    Qin, Li
    Faustino, E. Vincent S.
    PEDIATRIC RADIOLOGY, 2016, 46 (02) : 219 - 228
  • [20] Point-of-care hip ultrasound in a pediatric emergency department
    Cruz, Christopher I.
    Vieira, Rebecca L.
    Mannix, Rebekah C.
    Monuteaux, Michael C.
    Levy, Jason A.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (07) : 1174 - 1177