Development and validation of a three-dimensional finite element model of lumbo-pelvic-femoral complex

被引:0
作者
Zhu, Rui [1 ]
Cheng, Liming [1 ]
Yu, Yan [1 ]
Lv, Haoxuan [1 ]
Jia, Yongwei [1 ]
Zeng, Zhili [1 ]
Chen, Bo [2 ]
Ding, Zuquan [2 ]
机构
[1] Tongji Univ, Dept Orthoped, Tongji Hosp, Shanghai 200092, Peoples R China
[2] Tongji Univ, Coll Life, Dept Sci & Technol, Shanghai, Peoples R China
来源
2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11 | 2009年
关键词
lumbar; pelvis; femur; lumbo-pelvic-femoral complex; finite element; HIP; RECONSTRUCTION; SACRECTOMY; FUSION; DISC; BONE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The study is to develop a three-dimensional finite element model to study the disease related to lumbo-pelvic-femoral complex. The CT images from the first lumbar vertebra to the upper third of femurs of a 25-years-old healthy male were obtained. Triangle mesh model was generated using these images by Simpleware. Then the whole solid model were set up after repair and optimization in Geomagic. The finite element model was established and analyzed using ABAQUS. The three-dimensional finite element model of pelvis-lumbar-femur (3D-FEMLPFC) had 106557 nodes and 435736 elements. The difference of anatomic shape between 3D-FEMLPFC and CT images was between -0.74 mm and 1.64 mm in absolute error, and between -1.39% and 3.16% in relative error. It was high similar with specimen in geometric shape. The stress distribution of 3D-FEMLPFC was the same as clinical observation and published literatures. It was valid and reasonable and could be used for biomechanical analysis.
引用
收藏
页码:2757 / +
页数:2
相关论文
共 23 条
  • [1] Subject-specific finite element model of the pelvis: Development, validation and sensitivity studies
    Anderson, AE
    Peters, CL
    Tuttle, BD
    Weiss, JA
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (03): : 364 - 373
  • [2] Loss in mechanical contact of cementless acetabular prostheses due to post-operative weight bearing: A biomechanical model
    Bellini, Chiara Maria
    Galbusera, Fabio
    Ceroni, Roberto Giacometti
    Raimondi, Manuela Teresa
    [J]. MEDICAL ENGINEERING & PHYSICS, 2007, 29 (02) : 175 - 181
  • [3] Residual sagittal motion after lumbar fusion - A finite element analysis with implications on radiographic flexion-extension criteria
    Bono, Christopher M.
    Khandha, Ashutosh
    Vadapalli, S.
    Holekamp, Scott
    Goel, Vijay K.
    Garfin, Steven R.
    [J]. SPINE, 2007, 32 (04) : 417 - 422
  • [4] Cheng Li-Ming, 2007, Zhonghua Yi Xue Za Zhi, V87, P3346
  • [5] DEVELOPMENT AND VALIDATION OF A 3-DIMENSIONAL FINITE-ELEMENT MODEL OF THE PELVIC BONE
    DALSTRA, M
    HUISKES, R
    VANERNING, L
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (03): : 272 - 278
  • [6] Analysis of the structural behavior of the pelvis during lateral impact using the finite element method
    Dawson, JM
    Khmelniker, BV
    McAndrew, MP
    [J]. ACCIDENT ANALYSIS AND PREVENTION, 1999, 31 (1-2) : 109 - 119
  • [7] Biomechanical comparison between fusion of two vertebrae and implantation of an artificial intervertebral disc
    Denozière, G
    Ku, DN
    [J]. JOURNAL OF BIOMECHANICS, 2006, 39 (04) : 766 - 775
  • [8] Hip and sacroiliac disease: Selected disorders and their management with physical therapy
    Edge-Hughes, Laurie
    [J]. CLINICAL TECHNIQUES IN SMALL ANIMAL PRACTICE, 2007, 22 (04): : 183 - 194
  • [9] Freitag LA, 2000, INT J NUMER METH ENG, V49, P109, DOI 10.1002/1097-0207(20000910/20)49:1/2<109::AID-NME925>3.3.CO
  • [10] 2-L