Visualizing bone porosities using a tabletop scanning electron microscope

被引:0
|
作者
Krishnamoorthy, D. [1 ]
DaPonte, J. [2 ]
Broadbridge, C. C. [3 ]
Daniel, D. [3 ]
Alter, L. [4 ]
机构
[1] Carnegie Mellon Univ, Dept Mat Sci & Biomed Engn, Pittsburgh, PA 15213 USA
[2] Southern Connecticut State Univ, Dept Comp Sci, New Haven, CT 06515 USA
[3] Southern Connecticut State Univ, Dept Phys, New Haven, CT 06515 USA
[4] Wilber Cross High Sch, Dept Sci, New Haven, CT USA
来源
VISUAL INFORMATION PROCESSING XIX | 2010年 / 7701卷
关键词
scanning electron microscope; periosteal; intracortical; threshold; particle analysis;
D O I
10.1117/12.850246
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Pores are naturally occurring entities in bone. Changes in pore size and number are often associated with diseases such as Osteoporosis and even microgravity during spaceflight. Studying bone perforations may yield great insight into bone's material properties, including bone density and may contribute to identifying therapies to halt or potentially reverse bone loss. Current technologies used in this field include nuclear magnetic resonance, micro-computed tomography and the field emission scanning electron microscope (FE-SEM) (2, 5). However, limitations in each method limit further advancement. The objective of this study was to assess the effectiveness of using a new generation of analytical instruments, the TM-1000 tabletop, SEM with back-scatter electron (BSE) detector, to analyze cortical bone porosities. Hind limb unloaded and age-based controlled mouse femurs were extracted and tested in vitro for changes in pores on the periosteal surface. An important advantage of using the tabletop is the simplified sample preparation that excludes extra coatings, dehydration and fixation steps that are otherwise required for conventional SEM. For quantitative data, pores were treated as particles in order to use an analyze particles feature in the NIH ImageJ software. Several image-processing techniques for background smoothing, thresholding and filtering were employed to produce a binary image suitable for particle analysis. It was hypothesized that the unloaded bones would show an increase in pore area, as the lack of mechanical loading would affect bone-remodeling processes taking place in and around pores. Preliminary results suggest only a slight different in frequency but not in size of pores between unloaded and control femurs.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Mineral identification using a scanning electron microscope
    Harding, DP
    MINERALS & METALLURGICAL PROCESSING, 2002, 19 (04) : 215 - 219
  • [2] Mineral identification using a scanning electron microscope
    D. P. Harding
    Mining, Metallurgy & Exploration, 2002, 19 : 215 - 219
  • [3] Investigation of degraded bone substitutes made of magnesium alloy using scanning electron microscope and nanoindentation
    Gartzke, Ann-Kathrin
    Julmi, Stefan
    Klose, Christian
    Besdo, Silke
    Waselau, Anja-Christina
    Meyer-Lindenberg, Andrea
    Maier, Hans Juergen
    Wriggers, Peter
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 109
  • [4] Nanomanipulation in a scanning electron microscope
    Fahlbusch, S
    Mazerolle, S
    Breguet, JM
    Steinecker, A
    Agnus, J
    Pérez, R
    Michler, J
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2005, 167 (2-3) : 371 - 382
  • [5] Mechanical scanning of the specmen in the scanning electron microscope
    Oho, E
    Miyamoto, M
    SCANNING, 2004, 26 (05) : 250 - 255
  • [6] Design for an aberration corrected scanning electron microscope using miniature electron mirrors
    Dohi, Hideto
    Kruit, Pieter
    ULTRAMICROSCOPY, 2018, 189 : 1 - 23
  • [7] Nanotip electron gun for the scanning electron microscope
    Vladar, Andras E.
    Radi, Zsolt
    Postek, Michael T.
    Joy, David C.
    SCANNING, 2006, 28 (03) : 133 - 141
  • [8] 3D-measurement using a scanning electron microscope
    Reithmeier, Eduard
    Vynnyk, Taras
    Schultheis, Thanin
    APPLIED MATHEMATICS AND COMPUTATION, 2010, 217 (03) : 1193 - 1201
  • [9] Assessment of the Inner Surface Microstructure of Decellularized Cortical Bone by a Scanning Electron Microscope
    Jeong, Heonuk
    Asai, Jungo
    Ushida, Takashi
    Furukawa, Katsuko S.
    BIOENGINEERING-BASEL, 2019, 6 (03):
  • [10] Scan nonlinearity of a scanning electron microscope
    V. V. Alzoba
    V. P. Gavrilenko
    A. Yu. Kuzin
    V. B. Mityukhlyaev
    A. V. Rakov
    P. A. Todua
    M. N. Filippov
    Measurement Techniques, 2012, 55 : 1001 - 1004