Durability of femorofemoral bypass grafting after aortouniiliac endovascular aneurysm repair

被引:61
作者
Hinchliffe, RJ [1 ]
Alric, P [1 ]
Wenham, PW [1 ]
Hopkinson, BR [1 ]
机构
[1] Univ Nottingham Hosp, Dept Vasc & Endovasc Surg, Nottingham NG7 2UH, England
关键词
D O I
10.1016/S0741-5214(03)00415-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Endovascular aneurysm repair (EVAR) with aortouniiliac prostheses extends the morphologic range of aneurysms that can be treated and is potentially a more rapid and simple operation than bifurcated endovascular repair. It may, however, be limited by durability of the femorofemoral extra-anatomic bypass graft required to revascularize the contralateral lower limb. Previous studies of femorofemoral bypass grafts were performed almost exclusively in patients with occlusive disease. An 8-year single center experience with use of the femorofemoral bypass graft in aneurysmal disease is reported. Methods. All patients undergoing EVAR with an aortouniiliac endovascular stent graft over eight years (1994-2002) at a single institution were included in a retrospective study. Patient data were collected from a prospectively maintained local endovascular database. All patients gave informed consent and were part of an endovascular program approved by the local ethics committee. Results. Over the 8 years, 231 patients underwent EVAR with an aortouniiliac endovascular stent-graft. Median follow-up was 22 months. Localized wound complications were observed in 25 patients (11%). Cumulative 3-year patency rate for the femorofemoral bypass graft was 91%. At the end of 5-years 83% of grafts remained patent. Conclusions. The femorofemoral bypass graft used during EVAR with aortouniliac stent grafts offers encouraging medium and long-term patency. When graft occlusion occurs, it is usually directly attributable to inadequate inflow from the endovascular stent graft itself or to endoluminal damage of the external iliac artery. Awareness and early detection of stent-graft distortion or complications in the external iliac artery may result in improved patency rates.
引用
收藏
页码:498 / 503
页数:6
相关论文
共 25 条
[1]   Anatomical suitability of abdominal aortic aneurysms for endovascular repair [J].
Armon, MP ;
Yusuf, SW ;
Latief, K ;
Whitaker, SC ;
Gregson, RHS ;
Wenham, PW ;
Hopkinson, BR .
BRITISH JOURNAL OF SURGERY, 1997, 84 (02) :178-180
[2]  
Bohannon WT, 2002, J VASC SURG, V35, P584, DOI 10.1067/mva.2002.120374
[3]   Failure of endovascular abdominal aortic aneurysm graft limbs [J].
Carpenter, JP ;
Neschis, DG ;
Fairman, RM ;
Barker, CF ;
Golden, MA ;
Velazquez, OC ;
Mitchell, ME ;
Baum, RA .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (02) :296-302
[4]   Predicting iliac limb occlusions after bifurcated aortic stent grafting: Anatomic and device-related causes [J].
Carroccio, A ;
Faries, PL ;
Morrissey, NJ ;
Teodorescu, V ;
Burks, JA ;
Gravereaux, EC ;
Hollier, LH ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2002, 36 (04) :679-684
[5]  
Chuter T A, 1999, Semin Vasc Surg, V12, P176
[6]   Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repair [J].
Chuter, TAM ;
Risberg, B ;
Hopkinson, BR ;
Wendt, G ;
Scott, RAP ;
Walker, PJ ;
Viscomi, S ;
White, G .
JOURNAL OF VASCULAR SURGERY, 1996, 24 (04) :655-666
[7]  
DICK LS, 1980, ARCH SURG-CHICAGO, V115, P1359
[8]   FEMOROFEMORAL BYPASS - A PROFILE OF GRAFT FAILURE [J].
FARBER, MA ;
HOLLIER, LH ;
EUBANKS, R ;
OCHSNER, JL ;
BOWEN, JC .
SOUTHERN MEDICAL JOURNAL, 1990, 83 (12) :1437-1443
[9]   A multicenter experience with the Talent endovascular graft for the treatment of abdominal aortic aneurysms [J].
Faries, PL ;
Brener, BJ ;
Connelly, TL ;
Katzen, BT ;
Briggs, VL ;
Burks, JA ;
Gravereaux, EC ;
Carroccio, A ;
Morrissey, NJ ;
Teodorescu, V ;
Won, J ;
Sparacino, S ;
Chae, KS ;
Hollier, LH ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (06) :1123-1128
[10]  
FOSTER MC, 1986, ANN ROY COLL SURG, V68, P216