Ionic contrast across a lipid membrane for Debye length extension: towards an ultimate bioelectronic transducer

被引:21
作者
Lee, Donggeun [1 ,2 ]
Jung, Woo Hyuk [3 ]
Lee, Suho [4 ]
Yu, Eui-Sang [1 ]
Lee, Taikjin [1 ]
Kim, Jae Hun [1 ]
Song, Hyun Seok [1 ]
Lee, Kwan Hyi [5 ,6 ]
Lee, Seok [1 ]
Han, Sang-Kook [2 ]
Choi, Myung Chul [4 ]
Ahn, Dong June [3 ,6 ]
Ryu, Yong-Sang [1 ,6 ]
Kim, Chulki [1 ]
机构
[1] Korea Inst Sci & Technol, Sensor Syst Res Ctr, Seoul, South Korea
[2] Yonsei Univ, Dept Elect & Elect Engn, Seoul, South Korea
[3] Korea Univ, Dept Chem & Biol Engn, Seoul, South Korea
[4] Korea Adv Inst Sci & Technol KAIST, Dept Bio & Brain Engn, Daejeon, South Korea
[5] Korea Inst Sci & Technol, Ctr Biomat, Seoul, South Korea
[6] Korea Univ, KU KIST Grad Sch Converging Sci & Technol, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
ELECTRICAL DETECTION; MOLECULAR-DYNAMICS; DNA HYBRIDIZATION; FIELD; SENSORS; AVIDIN; TRANSISTORS; DISEASE; BINDING;
D O I
10.1038/s41467-021-24122-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Despite technological advances in biomolecule detections, evaluation of molecular interactions via potentiometric devices under ion-enriched solutions has remained a long-standing problem. To avoid severe performance degradation of bioelectronics by ionic screening effects, we cover probe surfaces of field effect transistors with a single film of the supported lipid bilayer, and realize respectable potentiometric signals from receptor-ligand bindings irrespective of ionic strength of bulky solutions by placing an ion-free water layer underneath the supported lipid bilayer. High-energy X-ray reflectometry together with the circuit analysis and molecular dynamics simulation discovered biochemical findings that effective electrical signals dominantly originated from the sub-nanoscale conformational change of lipids in the course of receptor-ligand bindings. Beyond thorough analysis on the underlying mechanism at the molecular level, the proposed supported lipid bilayer-field effect transistor platform ensures the world-record level of sensitivity in molecular detection with excellent reproducibility regardless of molecular charges and environmental ionic conditions. The design of bioelectronic devices that enables accurate detection of biomolecules in ionic solutions at physiologically-relevant concentrations remains a challenge. Here, the authors report a ion-impermeable supported lipid bilayer-assisted field-effect transistor platform for biomolecule detection.
引用
收藏
页数:9
相关论文
共 55 条
  • [1] Gromacs: High performance molecular simulations through multi-level parallelism from laptops to supercomputers
    Abraham, Mark James
    Murtola, Teemu
    Schulz, Roland
    Páll, Szilárd
    Smith, Jeremy C.
    Hess, Berk
    Lindah, Erik
    [J]. SoftwareX, 2015, 1-2 : 19 - 25
  • [2] A Bioelectronic Platform Using a Graphene-Lipid Bilayer Interface
    Ang, Priscilla Kailian
    Jaiswal, Manu
    Lim, Candy Haley Yi Xuan
    Wang, Yu
    Sankaran, Jagadish
    Li, Ang
    Lim, Chwee Teck
    Wohland, Thorsten
    Oezyilmaz, Barbaros
    Loh, Kian Ping
    [J]. ACS NANO, 2010, 4 (12) : 7387 - 7394
  • [3] Surface Sensitive Analysis Device using Model Membrane and Challenges for Biosensor-chip
    Baek, Ji Min
    Ryu, Yong-Sang
    [J]. BIOCHIP JOURNAL, 2020, 14 (01) : 110 - 123
  • [4] SARS-CoV fusion peptides induce membrane surface ordering and curvature
    Basso, Luis G. M.
    Vicente, Eduardo F.
    Crusca, Edson, Jr.
    Cilli, Eduardo M.
    Costa-Filho, Antonio J.
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [5] MOLECULAR-DYNAMICS WITH COUPLING TO AN EXTERNAL BATH
    BERENDSEN, HJC
    POSTMA, JPM
    VANGUNSTEREN, WF
    DINOLA, A
    HAAK, JR
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1984, 81 (08) : 3684 - 3690
  • [6] Quantitative real-time measurements of DNA hybridization with alkylated nonoxidized silicon nanowires in electrolyte solution
    Bunimovich, Yuri L.
    Shin, Young Shik
    Yeo, Woon-Seok
    Amori, Michael
    Kwong, Gabriel
    Heath, James R.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (50) : 16323 - 16331
  • [7] Canonical sampling through velocity rescaling
    Bussi, Giovanni
    Donadio, Davide
    Parrinello, Michele
    [J]. JOURNAL OF CHEMICAL PHYSICS, 2007, 126 (01)
  • [8] Label-Free Electrical Detection of Cardiac Biomarker with Complementary Metal-Oxide Semiconductor-Compatible Silicon Nanowire Sensor Arrays
    Chua, Jay Huiyi
    Chee, Ru-Ern
    Agarwal, Ajay
    Wong, She Mein
    Zhang, Guo-Jun
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (15) : 6266 - 6271
  • [9] LIPID FILMS AS TRANSDUCERS FOR DETECTION OF ANTIGEN-ANTIBODY AND ENZYME-SUBSTRATE REACTIONS
    DELCASTI.J
    RODRIGUEZ, A
    ROMERO, CA
    SANCHEZ, V
    [J]. SCIENCE, 1966, 153 (3732) : 185 - +
  • [10] Duan XX, 2012, NAT NANOTECHNOL, V7, P401, DOI [10.1038/nnano.2012.82, 10.1038/NNANO.2012.82]