Reliability and Reproducibility of Hadamard Encoded Pseudo-Continuous Arterial Spin Labeling in Healthy Elderly

被引:6
|
作者
Neumann, Katja [1 ]
Schidlowski, Martin [2 ,3 ]
Guenther, Matthias [4 ,5 ]
Stoecker, Tony [2 ,6 ]
Duezel, Emrah [1 ,7 ,8 ,9 ]
机构
[1] German Ctr Neurodegenerat Dis DZNE, Magdeburg, Germany
[2] German Ctr Neurodegenerat Dis DZNE, Bonn, Germany
[3] Univ Bonn, Dept Epileptol, Med Ctr, Bonn, Germany
[4] Fraunhofer Inst Digital Med MEVIS, Bremen, Germany
[5] Univ Bremen, MR Imaging & Spect, Bremen, Germany
[6] Univ Bonn, Dept Phys & Astron, Bonn, Germany
[7] Otto von Guericke Univ, Inst Cognit Neurol & Dementia Res, Magdeburg, Germany
[8] UCL, Inst Cognit Neurosci, London, England
[9] Ctr Behav Brain Sci, Magdeburg, Germany
关键词
arterial spin labeling; pCASL; reliability; reproducibility; perfusion; cerebral blood flow; arterial transit time; hadamard encoding; CEREBRAL-BLOOD-FLOW; BOLUS ARRIVAL-TIME; INVERSION; MRI; INFERENCE; MODEL; AGE;
D O I
10.3389/fnins.2021.711898
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The perfusion parameters cerebral blood flow (CBF) and arterial transit time (ATT) measured with arterial spin labeling (ASL) magnetic resonance imaging (MRI) provide valuable essentials to assess the integrity of cerebral tissue. Brain perfusion changes, due to aging, an intervention, or neurodegenerative diseases for example, could be investigated in longitudinal ASL studies with reliable ASL sequences. Generally, pseudo-continuous ASL (pCASL) is preferred because of its larger signal-to-noise ratio (SNR) compared to pulsed ASL (PASL) techniques. Available pCASL versions differ regarding their feature details. To date only little is known about the reliability and reproducibility of CBF and ATT measures obtained with the innovative Hadamard encoded pCASL variant, especially if applied on participants in old age. Therefore, we investigated an in-house developed Hadamard encoded pCASL sequence on a group of healthy elderly at two different 3 Tesla Siemens MRI systems (Skyra and mMR Biograph) and evaluated CBF and ATT reliability and reproducibility for several regions-of-interests (ROI). Calculated within-subject coefficients of variation (wsCV) demonstrated an excellent reliability of perfusion measures, whereas ATT appeared to be even more reliable than CBF [e.g., wsCV(CBF) = 2.9% vs. wsCV(ATT) = 2.3% for a gray matter (GM) ROI on Skyra system]. Additionally, a substantial agreement of perfusion values acquired on both MRI systems with an inter-session interval of 78 +/- 17.6 days was shown by high corresponding intra-class correlation (ICC) coefficients [e.g., ICC(CBF) = 0.704 and ICC(ATT) = 0.754 for a GM ROI]. The usability of this novel Hadamard encoded pCASL sequence might improve future follow-up perfusion studies of the aging and/or diseased brain.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Characterization of Skull Base Lesions Using Pseudo-Continuous Arterial Spin Labeling
    Geerts, B.
    Leclercq, D.
    du Montcel, S. Tezenas
    Law-ye, B.
    Gerber, S.
    Bernardeschi, D.
    Galanaud, D.
    Dormont, D.
    Pyatigorskaya, N.
    CLINICAL NEURORADIOLOGY, 2019, 29 (01) : 75 - 86
  • [32] Time-encoded pseudo-continuous arterial spin labeling: Increasing SNR in ASL dynamic angiography
    Woods, Joseph G.
    Schauman, S. Sophie
    Chiew, Mark
    Chappell, Michael A.
    Okell, Thomas W.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (04) : 1323 - 1341
  • [33] Reliability and precision of pseudo-continuous arterial spin labeling perfusion MRI on 3.0 T and comparison with 15O-water PET in elderly subjects at risk for Alzheimer's disease
    Xu, Guofan
    Rowley, Howard A.
    Wu, Gaohong
    Alsop, David C.
    Shankaranarayanan, Ajit
    Dowling, Maritza
    Christian, Bradley T.
    Oakes, Terrence R.
    Johnson, Sterling C.
    NMR IN BIOMEDICINE, 2010, 23 (03) : 286 - 293
  • [34] Longitudinal Reproducibility of MR Perfusion Using 3D Pseudocontinuous Arterial Spin Labeling With Hadamard-Encoded Multiple Postlabeling Delays
    Cohen, Alexander D.
    Agarwal, Mohit
    Jagra, Amritpal S.
    Nencka, Andrew S.
    Meier, Timothy B.
    Lebel, R. Marc
    McCrea, Michael A.
    Wang, Yang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (06) : 1846 - 1853
  • [35] B0 field inhomogeneity considerations in pseudo-continuous arterial spin labeling (pCASL): effects on tagging efficiency and correction strategy
    Jahanian, Hesamoddin
    Noll, Douglas C.
    Hernandez-Garcia, Luis
    NMR IN BIOMEDICINE, 2011, 24 (10) : 1202 - 1209
  • [36] Comparison of relative cerebral blood flow maps using pseudo-continuous arterial spin labeling and single photon emission computed tomography
    Liu, Peiying
    Uh, Jinsoo
    Devous, Michael D.
    Adinoff, Bryon
    Lu, Hanzhang
    NMR IN BIOMEDICINE, 2012, 25 (05) : 779 - 786
  • [37] High-Resolution Mouse Kidney Perfusion Imaging by Pseudo-Continuous Arterial Spin Labeling at 11.75T
    Duhamel, Guillaume
    Prevost, Valentin
    Girard, Olivier M.
    Callot, Virginie
    Cozzone, Patrick J.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 1186 - 1196
  • [38] Improving the robustness of pseudo-continuous arterial spin labeling to off-resonance and pulsatile flow velocity
    Zhao, Li
    Vidorreta, Marta
    Soman, Salil
    Detre, John A.
    Alsop, David C.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (04) : 1342 - 1351
  • [39] Reduction of BOLD interference in pseudo-continuous arterial spin labeling: towards quantitative fMRI
    Warnock, Geoffrey
    Oezbay, Pinar S.
    Kuhn, Felix P.
    Nanz, Daniel
    Buck, Alfred
    Boss, Andreas
    Rossi, Cristina
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2018, 38 (05) : 847 - 856
  • [40] Reliability of Two-Dimensional and Three-Dimensional Pseudo-Continuous Arterial Spin Labeling Perfusion MRI in Elderly Populations: Comparison With 15O-Water Positron Emission Tomography
    Kilroy, Emily
    Apostolova, Liana
    Liu, Collin
    Yan, Lirong
    Ringman, John
    Wang, Danny J. J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (04) : 931 - 939