Reliability and Reproducibility of Hadamard Encoded Pseudo-Continuous Arterial Spin Labeling in Healthy Elderly

被引:6
|
作者
Neumann, Katja [1 ]
Schidlowski, Martin [2 ,3 ]
Guenther, Matthias [4 ,5 ]
Stoecker, Tony [2 ,6 ]
Duezel, Emrah [1 ,7 ,8 ,9 ]
机构
[1] German Ctr Neurodegenerat Dis DZNE, Magdeburg, Germany
[2] German Ctr Neurodegenerat Dis DZNE, Bonn, Germany
[3] Univ Bonn, Dept Epileptol, Med Ctr, Bonn, Germany
[4] Fraunhofer Inst Digital Med MEVIS, Bremen, Germany
[5] Univ Bremen, MR Imaging & Spect, Bremen, Germany
[6] Univ Bonn, Dept Phys & Astron, Bonn, Germany
[7] Otto von Guericke Univ, Inst Cognit Neurol & Dementia Res, Magdeburg, Germany
[8] UCL, Inst Cognit Neurosci, London, England
[9] Ctr Behav Brain Sci, Magdeburg, Germany
关键词
arterial spin labeling; pCASL; reliability; reproducibility; perfusion; cerebral blood flow; arterial transit time; hadamard encoding; CEREBRAL-BLOOD-FLOW; BOLUS ARRIVAL-TIME; INVERSION; MRI; INFERENCE; MODEL; AGE;
D O I
10.3389/fnins.2021.711898
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The perfusion parameters cerebral blood flow (CBF) and arterial transit time (ATT) measured with arterial spin labeling (ASL) magnetic resonance imaging (MRI) provide valuable essentials to assess the integrity of cerebral tissue. Brain perfusion changes, due to aging, an intervention, or neurodegenerative diseases for example, could be investigated in longitudinal ASL studies with reliable ASL sequences. Generally, pseudo-continuous ASL (pCASL) is preferred because of its larger signal-to-noise ratio (SNR) compared to pulsed ASL (PASL) techniques. Available pCASL versions differ regarding their feature details. To date only little is known about the reliability and reproducibility of CBF and ATT measures obtained with the innovative Hadamard encoded pCASL variant, especially if applied on participants in old age. Therefore, we investigated an in-house developed Hadamard encoded pCASL sequence on a group of healthy elderly at two different 3 Tesla Siemens MRI systems (Skyra and mMR Biograph) and evaluated CBF and ATT reliability and reproducibility for several regions-of-interests (ROI). Calculated within-subject coefficients of variation (wsCV) demonstrated an excellent reliability of perfusion measures, whereas ATT appeared to be even more reliable than CBF [e.g., wsCV(CBF) = 2.9% vs. wsCV(ATT) = 2.3% for a gray matter (GM) ROI on Skyra system]. Additionally, a substantial agreement of perfusion values acquired on both MRI systems with an inter-session interval of 78 +/- 17.6 days was shown by high corresponding intra-class correlation (ICC) coefficients [e.g., ICC(CBF) = 0.704 and ICC(ATT) = 0.754 for a GM ROI]. The usability of this novel Hadamard encoded pCASL sequence might improve future follow-up perfusion studies of the aging and/or diseased brain.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] A systematic study of the sensitivity of partial volume correction methods for the quantification of perfusion from pseudo-continuous arterial spin labeling MRI
    Zhao, Moss Y.
    Mezue, Melvin
    Segerdahl, Andrew R.
    Okell, Thomas W.
    Tracey, Irene
    Xiao, Yingyi
    Chappell, Michael A.
    NEUROIMAGE, 2017, 162 : 384 - 397
  • [22] Investigation of control scans in pseudo-continuous arterial spin labeling (pCASL): Strategies for improving sensitivity and reliability of pCASL
    Han, Paul Kyu
    Choi, Seung Hong
    Park, Sung-Hong
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) : 917 - 929
  • [23] Interpulse phase corrections for unbalanced pseudo-continuous arterial spin labeling at high magnetic field
    Hirschler, Lydiane
    Debacker, Clement S.
    Voiron, Jerome
    Koehler, Sascha
    Warnking, Jan M.
    Barbier, Emmanuel L.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1314 - 1324
  • [24] Pseudo-continuous arterial spin labeling MRI study of schizophrenic patients
    Ota, Miho
    Ishikawa, Masanori
    Sato, Noriko
    Okazaki, Mitsutoshi
    Maikusa, Norihide
    Hori, Hiroaki
    Hattori, Kotaro
    Teraishi, Toshiya
    Ito, Kimiteru
    Kunugi, Hiroshi
    SCHIZOPHRENIA RESEARCH, 2014, 154 (1-3) : 113 - 118
  • [25] Measurement of brain perfusion in newborns: Pulsed arterial spin labeling (PASL) versus pseudo-continuous arterial spin labeling (pCASL)
    Boudes, Elodie
    Gilbert, Guillaume
    Leppert, Ilana Ruth
    Tan, Xianming
    Pike, G. Bruce
    Saint-Martin, Christine
    Wintermark, Pia
    NEUROIMAGE-CLINICAL, 2014, 6 : 126 - 133
  • [26] Cardiac-triggered pseudo-continuous arterial-spin-labeling: A cost-effective scheme to further enhance the reliability of arterial-spin-labeling MRI
    Li, Yang
    Mao, Deng
    Li, Zhiqiang
    Schaer, Michael
    Pillai, Jay J.
    Pipe, James G.
    Lu, Hanzhang
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (03) : 969 - 975
  • [27] Real-Time Functional MRI Using Pseudo-Continuous Arterial Spin Labeling
    Hernandez-Garcia, Luis
    Jahanian, Hesamoddin
    Greenwald, Mark K.
    Zubieta, Jon-Kar
    Peltier, Scott J.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (06) : 1570 - 1577
  • [28] Designing and comparing optimized pseudo-continuous Arterial Spin Labeling protocols for measurement of cerebral blood flow
    Woods, Joseph G.
    Chappell, Michael A.
    Okell, Thomas W.
    NEUROIMAGE, 2020, 223
  • [29] Optimization and reliability of multiple postlabeling delay pseudo-continuous arterial spin labeling during rest and stimulus-induced functional task activation
    Mezue, Melvin
    Segerdahl, Andrew R.
    Okell, Thomas W.
    Chappell, Michael A.
    Kelly, Michael E.
    Tracey, Irene
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2014, 34 (12) : 1919 - 1927
  • [30] Pseudo-continuous arterial spin labeling quantifies cerebral blood flow in patients with acute ischemic stroke and chronic lacunar stroke
    Guo, LingFei
    Zhang, Qun
    Ding, Linda
    Liu, Kai
    Ding, Kevin
    Jiang, Chuanwu
    Liu, Cheng
    Li, Kuncheng
    Cui, Li
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2014, 125 : 229 - 236