A Review of Total Harmonic Distortion Factors for the Measurement of Harmonic and Interharmonic Pollution in Modern Power Systems

被引:60
作者
Arranz-Gimon, Angel [1 ]
Zorita-Lamadrid, Angel [2 ]
Morinigo-Sotelo, Daniel [2 ]
Duque-Perez, Oscar [2 ]
机构
[1] Univers Valladolid, Dept Elect Technol, Valladolid 47011, Spain
[2] Univers Valladolid, Dept Elect Engn, Res Grp ADIRE, ITAP, Valladolid 47011, Spain
关键词
power quality indices; harmonic distortion rates; harmonic analysis; interharmonics; high-frequency spectral components; WAVE-FORM DISTORTION; FREQUENCY-RANGE; COMPONENTS;
D O I
10.3390/en14206467
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Harmonic distortion is one of the disturbances that most affects the quality of the electrical system. The widespread use of power electronic systems, especially power converters, has increased harmonic and interharmonic emission in a wide range of frequencies. Therefore, there are new needs in the measurement of harmonic distortion in modern electrical systems, such as measurement in the supra-harmonic range (> 2 kHz) and the measurement of interharmonics. The International Electrotechnical Commission (IEC) standards define new total harmonic distortion (THD) rates based on the concept of frequency groupings. However, the rates defined in the IEC standards have shortcomings when measuring signals such as those present in the outputs of power systems with abundant interharmonic content and presence of components in the supra-harmonic range. Therefore, in this work, a comparison is made between the different THD factors currently defined, both in the literature and in the standards, to show which of them are the most suitable for assessing harmonic and interharmonic contamination in power system signals such as those present at the output of inverters.</p>
引用
收藏
页数:38
相关论文
共 131 条
[1]  
Abdikarimuly R, 2016, IEEE INT POWER ELEC, P63, DOI 10.1109/EPEPEMC.2016.7751975
[2]   Impact of EV charging Station Penetration on Harmonic Distortion Level in Utility Distribution Network: A Case Study of Qatar [J].
Ahmed, Abdellahi ;
Iqbal, Atif ;
Khan, Irfan ;
Al-Wahedi, Abdulla ;
Mehrjerdi, Hasan ;
Rahman, Syed .
2021 IEEE TEXAS POWER AND ENERGY CONFERENCE (TPEC), 2021, :367-372
[3]   Theoretical and experimental comparison of total harmonic distortion factors for the evaluation of harmonic and interharmonic pollution of grid-connected photovoltaic systems [J].
Aiello, Massimo ;
Cataliotti, Antonio ;
Favuzza, Salvatore ;
Graditi, Giorgio .
IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (03) :1390-1397
[4]   Minimizing Total Harmonic Distortion of a Two-Level Voltage Source Inverter Using Optimal Third Harmonic Injection [J].
Albatran, Saher ;
Al Khalaileh, Abdel Rahman ;
Allabadi, Ahmad S. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (03) :3287-3297
[5]   PRECISION OF THE SINEFITTING-BASED TOTAL HARMONIC DISTORTION ESTIMATOR [J].
Alegria, Francisco C. .
METROLOGY AND MEASUREMENT SYSTEMS, 2016, 23 (01) :37-46
[6]  
Alfieri L, 2017, I C CLEAN ELECT POW, P636, DOI 10.1109/ICCEP.2017.8004756
[7]  
Alfieri L., 2017, THESIS U NAPLES FEDE
[8]   New Power Quality Indices for the Assessment of Waveform Distortions from 0 to 150 kHz in Power Systems with Renewable Generation and Modern Non-Linear Loads [J].
Alfieri, Luisa ;
Bracale, Antonio ;
Larsson, Anders .
ENERGIES, 2017, 10 (10)
[9]   Advances in reduction of total harmonic distortion in solar photovoltaic systems: A literature review [J].
Alhafadhi, Liqaa ;
Teh, Jiashen .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (04) :2455-2470
[10]  
An Z, 2019, C IND ELECT APPL, P1090, DOI [10.1109/iciea.2019.8834137, 10.1109/ICIEA.2019.8834137]