An iterative sinogram gap-filling method with object- and scanner-dedicated discrete cosine transform (DCT)-domain filters for high resolution PET scanners

被引:3
作者
Kim, Kwangdon [1 ]
Lee, Kisung [2 ]
Lee, Hakjae [3 ]
Joo, Sungkwan [4 ]
Kang, Jungwon [5 ]
机构
[1] Korea Univ, Dept IT Convergence, Anam Ro 145, Seoul, South Korea
[2] Korea Univ, Dept Bioconvergence Engn, Anam Ro 145, Seoul, South Korea
[3] Dept Bioconvergence Engn & Med Imaging Device Co, ARARE Lab, Anam Ro 145, Seoul, South Korea
[4] Korea Univ, Sch Elect Engn, Anam Ro 145, Seoul, South Korea
[5] Dankook Univ, Dept Elect & Elect Engn, 152 Jukjeon Ro, Yongin 16890, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
Gap filling; Positron emission tomography; DCT; Sinogram interpolation; DCT2; POSITRON-EMISSION-TOMOGRAPHY; ECAT HRRT; CANCER; IMAGES;
D O I
10.1007/s11604-017-0697-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We aimed to develop a gap-filling algorithm, in particular the filter mask design method of the algorithm, which optimizes the filter to the imaging object by an adaptive and iterative process, rather than by manual means. Two numerical phantoms (Shepp-Logan and Jaszczak) were used for sinogram generation. The algorithm works iteratively, not only on the gap-filling iteration but also on the mask generation, to identify the object-dedicated low frequency area in the DCT-domain that is to be preserved. We redefine the low frequency preserving region of the filter mask at every gap-filling iteration, and the region verges on the property of the original image in the DCT domain. The previous DCT2 mask for each phantom case had been manually well optimized, and the results show little difference from the reference image and sinogram. We observed little or no difference between the results of the manually optimized DCT2 algorithm and those of the proposed algorithm. The proposed algorithm works well for various types of scanning object and shows results that compare to those of the manually optimized DCT2 algorithm without perfect or full information of the imaging object.
引用
收藏
页码:59 / 67
页数:9
相关论文
共 21 条
[1]   Fast DCT-based spatial domain interpolation of blocks in images [J].
Alkachouh, Z ;
Bellanger, MG .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2000, 9 (04) :729-732
[2]  
[Anonymous], NUCL SCI S C REC 200
[3]  
De Jong H., 2002, 2002 IEEE NUCL SCI S, P1202
[4]   Exact and approximate rebinning algorithms for 3-D PET data [J].
Defrise, M ;
Kinahan, PE ;
Townsend, DW ;
Michel, C ;
Sibomana, M ;
Newport, DF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :145-158
[5]  
Eriksson L, 2002, IEEE T NUCL SCI, V49, P2085, DOI 10.1109/TNS.2002.803784
[6]   QUANTITATIVE-ANALYSIS OF D2 DOPAMINE RECEPTOR-BINDING IN THE LIVING HUMAN-BRAIN BY PET [J].
FARDE, L ;
HALL, H ;
EHRIN, E ;
SEDVALL, G .
SCIENCE, 1986, 231 (4735) :258-261
[7]   Molecular imaging of cancer with positron emission tomography [J].
Gambhir, SS .
NATURE REVIEWS CANCER, 2002, 2 (09) :683-693
[8]   Synthesis and evaluation of an F-18-labeled dopa prodrug as a PET tracer for studying brain dopamine metabolism [J].
Ishiwata, K ;
Shinoda, M ;
Ishii, SI ;
Nozaki, T ;
Senda, M .
NUCLEAR MEDICINE AND BIOLOGY, 1996, 23 (03) :295-301
[9]   Quantitative Analysis of Amyloid Deposition in Alzheimer Disease Using PET and the Radiotracer 11C-AZD2184 [J].
Ito, Hiroshi ;
Shimada, Hitoshi ;
Shinotoh, Hitoshi ;
Takano, Harumasa ;
Sasaki, Takeshi ;
Nogami, Tsuyoshi ;
Suzuki, Masayuki ;
Nagashima, Tomohisa ;
Takahata, Keisuke ;
Seki, Chie ;
Kodaka, Fumitoshi ;
Eguchi, Yoko ;
Fujiwara, Hironobu ;
Kimura, Yasuyuki ;
Hirano, Shigeki ;
Ikoma, Yoko ;
Higuchi, Makoto ;
Kawamura, Kazunori ;
Fukumura, Toshimitsu ;
Boo, Eva Lindstrom ;
Farde, Lars ;
Suhara, Tetsuya .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (06) :932-938
[10]   GATE:: a simulation toolkit for PET and SPECT [J].
Jan, S ;
Santin, G ;
Strul, D ;
Staelens, S ;
Assié, K ;
Autret, D ;
Avner, S ;
Barbier, R ;
Bardiès, M ;
Bloomfield, PM ;
Brasse, D ;
Breton, V ;
Bruyndonckx, P ;
Buvat, I ;
Chatziioannou, AF ;
Choi, Y ;
Chung, YH ;
Comtat, C ;
Donnarieix, D ;
Ferrer, L ;
Glick, SJ ;
Groiselle, CJ ;
Guez, D ;
Honore, PF ;
Kerhoas-Cavata, S ;
Kirov, AS ;
Kohli, V ;
Koole, M ;
Krieguer, M ;
van der Laan, DJ ;
Lamare, F ;
Largeron, G ;
Lartizien, C ;
Lazaro, D ;
Maas, MC ;
Maigne, L ;
Mayet, F ;
Melot, F ;
Merheb, C ;
Pennacchio, E ;
Perez, J ;
Pietrzyk, U ;
Rannou, FR ;
Rey, M ;
Schaart, DR ;
Schmidtlein, CR ;
Simon, L ;
Song, TY ;
Vieira, JM ;
Visvikis, D .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19) :4543-4561