For the first time polycrystalline HgI2 photoconductor material directly evaporated on a-Si array for direct conversion of x-rays for imaging purposes, were successfully imaged at Xerox-Palo Alto Research Center. The initial results are very promising and show a high x-ray sensitivity and low leakage current. Since Ti-W alloys are used as pixel electrodes, an intermediate passivation layer must be used to prevent a chemical reaction with the detector plate. The thickness that these Polycrystalline HgI2 thick film detectors have been fabricated till now is up to 1,800 mum, which makes them useful also for high energy applications. The characterization of the Polycrystalline HgI2 thick films deposited with or without the passivation layers by measuring their dark currents, sensitivity to 65 and 85 kVp X-rays and residual signals after 1 minute of biasing, will be shown for several detectors. Some preliminary results will be shown for some novel screen-printed HgI2 detectors.
引用
收藏
页码:197 / 204
页数:4
相关论文
共 50 条
  • [21] Recent advances in gamma- and X-ray spectrometry by means of mercuric iodide detectors
    Ponpon, JP
    Sieskind, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 173 - 178
  • [22] Low dark current (0 0 l) mercuric iodide thick films for X-ray direct and digital imagers
    Fornaro, L
    Cuña, A
    Noguera, A
    Aguiar, I
    Pérez, M
    Mussio, L
    Gancharov, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (06) : 3107 - 3110
  • [23] Low dark current (0 0 l) mercuric iodide thick films for X-ray direct and digital imagers
    Fornaro, L
    Cuña, A
    Noguera, A
    Aguiar, I
    Pérez, M
    Mussio, L
    Gancharov, A
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4560 - 4563
  • [24] SURFACE PROBLEMS OF MERCURIC IODIDE-CRYSTALS USED AS X-RAY AND GAMMA-RAY DETECTORS
    MOHAMMEDBRAHIM, T
    HAMOULI, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 314 - 316
  • [25] ADVANCES IN THE DEVELOPMENT OF ENCAPSULANTS FOR MERCURIC IODIDE X-RAY-DETECTORS
    IWANCZYK, JS
    WANG, YJ
    BRADLEY, JG
    ALBEE, AL
    SCHNEPPLE, WF
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (06) : 2214 - 2218
  • [26] Large area mercuric iodide x-ray imager
    Zentai, G
    Partain, L
    Pavlyuchkova, R
    Virshup, G
    Zuck, A
    Melekhov, L
    Dagan, O
    Vilensky, A
    Gilboa, H
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 592 - 600
  • [27] X-ray reflections from mercuric iodide.
    Havighurst, RJ
    AMERICAN JOURNAL OF SCIENCE, 1925, 10 (60) : 556 - 558
  • [28] MEASUREMENT OF THE CHARACTERISTIC X-RAY OF OXYGEN AND OTHER ULTRASOFT X-RAYS USING MERCURIC IODIDE DETECTORS
    IWANCZYK, JS
    DABROWSKI, AJ
    HUTH, GC
    ECONOMOU, TE
    APPLIED PHYSICS LETTERS, 1985, 46 (06) : 606 - 607
  • [29] Large area mercuric iodide and lead iodide X-ray detectors for medical and non-destructive industrial imaging
    Zentai, G.
    Schieber, M.
    Partain, L.
    Pavlyuchkova, R.
    Proano, C.
    JOURNAL OF CRYSTAL GROWTH, 2005, 275 (1-2) : E1327 - E1331
  • [30] Medical imaging with mercuric iodide direct digital radiography flat-panel X-ray detectors
    Schieber, M
    Hermon, H
    Zentai, G
    Partain, L
    Street, RA
    Gilboa, H
    RADIOLOGY, 2001, 221 : 464 - 464