Numerical-analytical study of earth-air heat exchangers with complex geometries guided by constructal design

被引:9
|
作者
Nunes, Bruna Rodrigues [1 ]
Rodrigues, Michel Kepes [1 ]
Oliveira Rocha, Luiz Alberto [2 ]
Labat, Matthieu [3 ]
Lorente, Sylvie [4 ]
dos Santos, Elizaldo Domingues [1 ]
Isoldi, Liercio Andre [1 ]
Biserni, Cesare [5 ]
机构
[1] Fed Univ Rio Grande FURG, Computat Modeling PPGMC, Rio Grande, Brazil
[2] Univ Vale Rio Sinos UNISINOS, Mech Engn, Porto Alegre, RS, Brazil
[3] Univ Toulouse, Natl Inst Appl Sci INSA, Lab Mat & Construct Durabil LMDC, Toulouse, France
[4] Villanova Univ, Dept Mech Engn, Villanova, PA 19085 USA
[5] Univ Bologna, Dept Ind Engn DIN, Alma Mater Studiorum, Bologna, Italy
关键词
complex geometric configurations; earth-air heat exchanger; pressure drop; soil volume; thermal potential; GROUND TEMPERATURE; PERFORMANCE ANALYSIS; THERMAL PERFORMANCE; ENERGY; SYSTEMS; EAHE; BUILDINGS; PREDICT; HOT;
D O I
10.1002/er.7157
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Significant advancements in developing earth-air heat exchanger models have been detected in the past several decades. It is worth mentioning that this type of device takes advantage of the Earth's constant temperature to cool or heat spaces in buildings so that the identification of its most appropriate geometric configurations to reduce energy consumption is still an actual challenge. In this context, the present paper is focused on the geometric evaluation of several earth-air heat exchangers arrangements according to the Constructal Design method. The performance indicators are the minimization of its soil volume occupation, the minimization of its airflow pressure drop, and the maximization of its thermal potential. Therefore, from a straight duct named Reference Installation, 26 complex geometries have been outlined here using the numerical-analytical investigation. Many ideas emerged from this study: the use of serpentine with low spacing between ducts reduced nearly 39% of the soil volume occupied by the device compared to Reference Installation, showing its applicability in urban regions. In addition, configurations with few curves benefited the decrease of air pressure drop, allowing a performance 30% superior to the most complex shapes. Instead, complex designs can be recommended for thermal potential increase, although the influence of the different configurations over this indicator was not substantial since the maximum improvement achieved between the best and worst shapes proved to be around 6%. Finally, when the three performance indicators are concomitantly considered, several complex geometries reached an overall performance superior to the Reference Installation.
引用
收藏
页码:20970 / 20987
页数:18
相关论文
共 50 条
  • [21] THERMAL ANALYSIS OF EARTH-AIR HEAT EXCHANGERS UNDER HEATING CONDITIONS AT A CONSTANT SURFACE TEMPERATURE
    Karadag, Refet
    Bulut, Husamettin
    Demirtas, Yunus
    Hilali, Ismail
    HEAT TRANSFER RESEARCH, 2018, 49 (18) : 1813 - 1823
  • [22] The impact of latent heat exchanges on the design of earth air heat exchangers
    Estrada, Emanuel
    Labat, Matthieu
    Lorente, Sylvie
    Rocha, Luiz A. O.
    APPLIED THERMAL ENGINEERING, 2018, 129 : 306 - 317
  • [23] Parametric Study of Earth-Air Heat Exchanger based on Physical Experimentation
    Goyal, Vaishali
    Asati, Arun Kumar
    Garg, Rajeev Kumar
    Arora, Amit
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2023, 30 (02) : 232 - 239
  • [24] Effect of geo-climatic conditions and pipe material on heating performance of earth-air heat exchangers
    Lekhal, Mohammed Cherif
    Benzaama, Mohammed-Hichem
    Kindinis, Andrea
    Mokhtari, Abderahmane-Mejedoub
    Belarbi, Rafik
    RENEWABLE ENERGY, 2021, 163 : 22 - 40
  • [25] A Review of Earth-Air Heat Exchangers: From Fundamental Principles to Hybrid Systems with Renewable Energy Integration
    Koshlak, Hanna
    ENERGIES, 2025, 18 (05)
  • [26] Numerical parametric study of a new earth-air heat exchanger configuration designed for hot and arid climates
    Benrachi, Naoufel
    Ouzzane, Mohamed
    Smaili, Arezki
    Lamarche, Louis
    Badache, Messaoud
    Maref, Wahid
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2020, 17 (02) : 115 - 126
  • [27] An analytical method to evaluate the impact of vertical part of an earth-air heat exchanger on the whole system
    Gomat, Landry Jean Pierre
    Motoula, Smael Magloire Elombo
    M'Passi-Mabiala, Bernard
    RENEWABLE ENERGY, 2020, 162 : 1005 - 1016
  • [28] Structural design method, validation, and performance analysis of an earth-air heat exchanger for greenhouses
    Xiao, Jinxin
    Hu, Yixin
    Wang, Qiang
    Li, Jianming
    GEOTHERMICS, 2023, 111
  • [29] Numerical and Experimental Analysis of an Earth-Air Heat Exchanger
    Diedrich, Carlos Henrique
    dos Santos, Gerson Henrique
    Carraro, Gustavo Chaves
    Dimbarre, Victor Vaurek
    Alves, Thiago Antonini
    ATMOSPHERE, 2023, 14 (07)
  • [30] Numerical study on the cooling performance of a novel passive system: Cylindrical phase change material-assisted earth-air heat exchanger
    Zhou, Tiecheng
    Xiao, Yimin
    Huang, Haotian
    Lin, Jianquan
    JOURNAL OF CLEANER PRODUCTION, 2020, 245