Numerical-analytical study of earth-air heat exchangers with complex geometries guided by constructal design

被引:9
|
作者
Nunes, Bruna Rodrigues [1 ]
Rodrigues, Michel Kepes [1 ]
Oliveira Rocha, Luiz Alberto [2 ]
Labat, Matthieu [3 ]
Lorente, Sylvie [4 ]
dos Santos, Elizaldo Domingues [1 ]
Isoldi, Liercio Andre [1 ]
Biserni, Cesare [5 ]
机构
[1] Fed Univ Rio Grande FURG, Computat Modeling PPGMC, Rio Grande, Brazil
[2] Univ Vale Rio Sinos UNISINOS, Mech Engn, Porto Alegre, RS, Brazil
[3] Univ Toulouse, Natl Inst Appl Sci INSA, Lab Mat & Construct Durabil LMDC, Toulouse, France
[4] Villanova Univ, Dept Mech Engn, Villanova, PA 19085 USA
[5] Univ Bologna, Dept Ind Engn DIN, Alma Mater Studiorum, Bologna, Italy
关键词
complex geometric configurations; earth-air heat exchanger; pressure drop; soil volume; thermal potential; GROUND TEMPERATURE; PERFORMANCE ANALYSIS; THERMAL PERFORMANCE; ENERGY; SYSTEMS; EAHE; BUILDINGS; PREDICT; HOT;
D O I
10.1002/er.7157
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Significant advancements in developing earth-air heat exchanger models have been detected in the past several decades. It is worth mentioning that this type of device takes advantage of the Earth's constant temperature to cool or heat spaces in buildings so that the identification of its most appropriate geometric configurations to reduce energy consumption is still an actual challenge. In this context, the present paper is focused on the geometric evaluation of several earth-air heat exchangers arrangements according to the Constructal Design method. The performance indicators are the minimization of its soil volume occupation, the minimization of its airflow pressure drop, and the maximization of its thermal potential. Therefore, from a straight duct named Reference Installation, 26 complex geometries have been outlined here using the numerical-analytical investigation. Many ideas emerged from this study: the use of serpentine with low spacing between ducts reduced nearly 39% of the soil volume occupied by the device compared to Reference Installation, showing its applicability in urban regions. In addition, configurations with few curves benefited the decrease of air pressure drop, allowing a performance 30% superior to the most complex shapes. Instead, complex designs can be recommended for thermal potential increase, although the influence of the different configurations over this indicator was not substantial since the maximum improvement achieved between the best and worst shapes proved to be around 6%. Finally, when the three performance indicators are concomitantly considered, several complex geometries reached an overall performance superior to the Reference Installation.
引用
收藏
页码:20970 / 20987
页数:18
相关论文
共 50 条
  • [1] A numerical study on cooling performance of different type earth-air heat exchangers
    Tasdelen, Fatih
    Dagtekin, Ihsan
    RENEWABLE ENERGY, 2025, 241
  • [2] An experimental study on the use of Earth-Air Heat Exchangers (EAHE)
    Vaz, Joaquim
    Sattler, Miguel A.
    Brum, Ruth da S.
    dos Santos, Elizaldo D.
    Isoldi, Liercio A.
    ENERGY AND BUILDINGS, 2014, 72 : 122 - 131
  • [3] Multi-Objective Numerical Analysis of Horizontal Rectilinear Earth-Air Heat Exchangers with Elliptical Cross Section Using Constructal Design and TOPSIS
    de Andrade, Ivanilton Reinato
    dos Santos, Elizaldo Domingues
    Zhang, Houlei
    Rocha, Luiz Alberto Oliveira
    Razera, Andre Luis
    Isoldi, Liercio Andre
    FLUIDS, 2024, 9 (11)
  • [4] Design evaluation of Earth-Air Heat Exchangers with multiple ducts
    Brum, Ruth S.
    Ramalho, Jairo V. A.
    Rodrigues, Michel K.
    Rocha, Luiz A. O.
    Isoldi, Liercio A.
    Dos Santos, Elizaldo D.
    RENEWABLE ENERGY, 2019, 135 : 1371 - 1385
  • [5] Fitting new constructal models for the thermal potential of earth-air heat exchangers
    de Alencar Ramalho, Jairo Valoes
    Brum, Ruth da Silva
    Oliveira Rocha, Luiz Alberto
    Isoldi, Liercio Andre
    dos Santos, Elizaldo Domingues
    Sulzbacher, Mariane
    ACTA SCIENTIARUM-TECHNOLOGY, 2018, 40
  • [6] Parametric optimization of earth-air heat exchangers (EAHEs) for central air conditioning
    Hegazi, A. . A. .
    Abdelrehim, O.
    Khater, A.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 129 (129) : 278 - 289
  • [7] A NUMERICAL STUDY ON HEATING PERFORMANCE OF HORIZONTAL AND VERTICAL EARTH-AIR HEAT EXCHANGERS WITH EQUAL PIPE LENGTHS
    Tasdelen, Fatih
    Dagtekin, Ihsan
    THERMAL SCIENCE, 2022, 26 (04): : 2929 - 2939
  • [8] Numerical investigation about the improvement of the thermal potential of an Earth-Air Heat Exchanger (EAHE) employing the Constructal Design method
    Rodrigues, Michel Kepes
    Brum, Ruth da Silva
    Vaz, Joaquim
    Oliveira Rocha, Luiz Alberto
    dos Santos, Elizaldo Domingues
    Isoldi, Liercio Andre
    RENEWABLE ENERGY, 2015, 80 : 538 - 551
  • [9] Experimental and numerical analysis of an earth-air heat exchanger
    Vaz, Joaquim
    Sattler, Miguel A.
    dos Santos, Elizaldo D.
    Isoldi, Liercio A.
    ENERGY AND BUILDINGS, 2011, 43 (09) : 2476 - 2482
  • [10] Improving the performances of earth air heat exchangers through Constructal design
    Brum, Ruth da Silva
    Labat, Matthieu
    Lorente, Sylvie
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (14) : 8822 - 8833