Diagnostic performance of quantitative κ and λ free light chain assays in clinical practice

被引:196
作者
Katzmann, JA
Abraham, RS
Dispenzieri, A
Lust, JA
Kyle, RA
机构
[1] Mayo Clin & Mayo Fdn, Coll Med, Dept Lab Med & Pathol, Div Clin Biochem & Immunol, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Coll Med, Dept Internal Med, Div Hematol, Rochester, MN 55905 USA
关键词
D O I
10.1373/clinchem.2004.046870
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The quantitative assay for free light chains (FLCs) is a recently introduced commercial test reported to be sensitive and specific for detecting FLC diseases such as primary systemic amyloidosis (AL), light chain deposition disease (LCDD), nonsecretory multiple myeloma (NSMM), and light chain multiple myeloma. We evaluated its diagnostic performance in clinical practice. Methods: All FLC clinical test results generated in 2003 were abstracted from the Laboratory Information System. Diagnoses were obtained from the Dysproteinemia database and the patient medical history. Results: In 2003, we received samples for FLC assays from 1020 Mayo Clinic patients. The majority of these patients (88%) had bone marrow-derived monoclonal plasma cell disorders (PCDs). The 121 patients who did not have. monoclonal gammopathy all had FLC kappa/lambda ratios within the range of values obtained for a reference population in our laboratory. Among the patients with monoclonal gammopathies were patients with multiple myeloma (330), AL (269), monoclonal gammopathy of undetermined significance (114), smoldering multiple myeloma (72), plasmacytoma (22), NSMM (20), macroglobulinemia (9), LCDD (7), and a variety of other PCDs. Among the 110 AL patients who had not been previously treated and who had a FLC assay performed within 120 days of diagnosis, the FLC kappa/lambda ratio was positive in 91% compared with 69% for serum immunofixation electrophoresis (IFE) and 83% for urine IFE. The combination of serum IFE and serum FLC assay detected an abnormal result in 99% (109 of 110) of patients with AL. Conclusion: The performance of the FLC assay in this analysis of clinical laboratory data is consistent with results from published retrospective validation studies. (c) 2005 American Association for Clinical Chemistry.
引用
收藏
页码:878 / 881
页数:4
相关论文
共 7 条
  • [1] Quantitative analysis of serum free light chains - A new marker for the diagnostic evaluation of primary systemic amyloidosis
    Abraham, RS
    Katzmann, JA
    Clark, RJ
    Bradwell, AR
    Kyle, RA
    Gertz, MA
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2003, 119 (02) : 274 - 278
  • [2] Bradwell AR, 2001, CLIN CHEM, V47, P673
  • [3] Serum test for assessment of patients with Bence Jones myeloma
    Bradwell, AR
    Carr-Smith, HD
    Mead, GP
    Harvey, TC
    Drayson, MT
    [J]. LANCET, 2003, 361 (9356) : 489 - 491
  • [4] Serum free light-chain measurements for identifying and monitoring patients with nonsecretory multiple myeloma
    Drayson, M
    Tang, LX
    Drew, R
    Mead, GP
    Carr-Smith, H
    Bradwell, AR
    [J]. BLOOD, 2001, 97 (09) : 2900 - 2902
  • [5] Katzmann JA, 2002, CLIN CHEM, V48, P1437
  • [6] Outcome in systemic AL amyloidosis in relation to changes in concentration of circulating free immunoglobulin light chains following chemotherapy
    Lachmann, HJ
    Gallimore, R
    Gillmore, JD
    Carr-Smith, HD
    Bradwell, AR
    Pepys, MB
    Hawkins, PN
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 2003, 122 (01) : 78 - 84
  • [7] Presence of monoclonal free light chains in the serum predicts risk of progression in monoclonal gammopathy of undetermined significance
    Rajkumar, SV
    Kyle, RA
    Therneau, TM
    Clark, RJ
    Bradwell, AR
    Melton, LJ
    Larson, DR
    Plevak, MF
    Katzmann, JA
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 2004, 127 (03) : 308 - 310