Novel metered aerosol valve

被引:2
作者
Nourian, Amir [1 ]
Nasr, Ghasem G. [1 ]
Yule, Andrew J. [1 ]
Hawthorne, Gary [2 ]
Goldberg, Tom [2 ]
机构
[1] Univ Salford, Sch Comp Sci & Engn CSE, Spray Res Grp, Phys & Mat Res Ctr, Manchester, Lancs, England
[2] Salford Valve Co Ltd Salvalco, Manchester, Lancs, England
关键词
Aerosol valve; spray metering; insert; inhaler; air-freshener;
D O I
10.1177/0954406215572839
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The design and performance of a new valving mechanism for portable pressurized spraying devices is described, where the propellant in the device is a safe gas (so-called compressed gas) propellant rather than the current liquefied gases all of which are either volatile organic compounds or greenhouse gases. The valve sprays a fixed volume of liquid when the spraying actuator is depressed, as is essential used medical sprays, such as pressurized metered dose inhalers and nasal sprays, and also for automatic (wall-mounted) aerosol delivery systems for air-fresheners, insecticides and disinfectants. For compressed gas' aerosol formats, there is no flash vaporization of propellant so that pumping liquid from a metering chamber and atomization to form a spray must be achieved entirely by designing some means of using the pumping action of the gas in the container to act upon the liquid in the metering chamber. The new design utilizes a loosely fitting spherical piston element and a simple arrangement of a concentric housing and a moveable valve stem, such that liquid flow paths between the different elements are automatically closed and opened in the correct time sequence when the valve stem is depressed and released. Spraying data show excellent repeatability of liquid sprayed per pulse throughout the lifetime of device and drop sizes that are acceptable for devices such as air-fresheners and nasal sprays. The valve has only one additional component compared with liquefied gas metered valves and can be straightforwardly injection moulded. As will be explained, previous attempts failed due to expense, complexity and unreliability.
引用
收藏
页码:1557 / 1568
页数:12
相关论文
共 50 条
  • [31] The Science Guiding Selection of an Aerosol Delivery Device
    Myers, Timothy R.
    RESPIRATORY CARE, 2013, 58 (11) : 1963 - 1973
  • [32] The thermostated medical jet nebulizer: Aerosol characteristics
    Ochowiak, M.
    Kasperkowiak, A.
    Doligalski, M.
    Sosnowski, T. R.
    Matuszak, M.
    Wlodarczak, S.
    Markowskaa, M.
    Krupinska, A.
    Jablczynska, K.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2019, 567
  • [33] Barriers to and competency with the use of metered dose inhaler and its impact on disease control among adult asthmatic patients in Ethiopia
    Tadesse Melaku Abegaz
    Efrata Ashuro Shegena
    Natnael Fentie Gessie
    Eyob Alemayehu Gebreyohannes
    Mohammed Assen Seid
    BMC Pulmonary Medicine, 20
  • [34] Environmental impact of pressurised metered dose inhalers versus dry powder and soft mist inhalers at a tertiary Melbourne hospital
    Cushnahan, Aiden
    Leaver, Benjamin
    Dunne, Ben
    Allman, Jacqui
    Rees, Megan
    INTERNAL MEDICINE JOURNAL, 2024, 54 (11) : 1898 - 1902
  • [35] Measurements of deposited aerosol dose in infants and small children
    Corcoran, Timothy E.
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (07)
  • [36] Assessment of the inhalation technique in outpatients with asthma or chronic obstructive pulmonary disease using a metered-dose inhaler or dry powder device
    van Beerendonk, I
    Mesters, I
    Mudde, AN
    Tan, TD
    JOURNAL OF ASTHMA, 1998, 35 (03) : 273 - 279
  • [37] Computer Modelling as a Tool in Characterization and Optimization of Aerosol Drug Delivery
    Farkas, Arpad
    Jokay, Agnes
    Fueri, Peter
    Balashazy, Imre
    Mueller, Veronika
    Odler, Balazs
    Horvath, Alpar
    AEROSOL AND AIR QUALITY RESEARCH, 2015, 15 (06) : 2466 - 2474
  • [38] Clinical comparability between the CFC and HFA budesonide pressurised metered-dose inhalers in paediatric patients with asthma:: a randomised controlled trial
    Escribano, A.
    Tutuncu, A.
    Loehr, I.
    Carlholm, M.
    Polanowski, T.
    CURRENT MEDICAL RESEARCH AND OPINION, 2006, 22 (06) : 1085 - 1092
  • [39] Patient Satisfaction with a Pressurized Metered-Dose Inhaler with an Integrated Dose Counter Containing a Fixed-Dose Mometasone Furoate/Formoterol Combination
    LaForce, Craig
    Weinstein, Cindy
    Nathan, Robert A.
    Weinstein, Steven F.
    Staudinger, Heribert
    Meltzer, Eli O.
    JOURNAL OF ASTHMA, 2011, 48 (06) : 625 - 631
  • [40] Comparative in vivo lung delivery of hydrofluoroalkane-salbutamol formulation via metered-dose inhaler alone, with plastic spacer, or with cardboard tube
    Fowler, SJ
    Wilson, AM
    Griffiths, EA
    Lipworth, BJ
    CHEST, 2001, 119 (04) : 1018 - 1020