Novel metered aerosol valve

被引:2
作者
Nourian, Amir [1 ]
Nasr, Ghasem G. [1 ]
Yule, Andrew J. [1 ]
Hawthorne, Gary [2 ]
Goldberg, Tom [2 ]
机构
[1] Univ Salford, Sch Comp Sci & Engn CSE, Spray Res Grp, Phys & Mat Res Ctr, Manchester, Lancs, England
[2] Salford Valve Co Ltd Salvalco, Manchester, Lancs, England
关键词
Aerosol valve; spray metering; insert; inhaler; air-freshener;
D O I
10.1177/0954406215572839
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The design and performance of a new valving mechanism for portable pressurized spraying devices is described, where the propellant in the device is a safe gas (so-called compressed gas) propellant rather than the current liquefied gases all of which are either volatile organic compounds or greenhouse gases. The valve sprays a fixed volume of liquid when the spraying actuator is depressed, as is essential used medical sprays, such as pressurized metered dose inhalers and nasal sprays, and also for automatic (wall-mounted) aerosol delivery systems for air-fresheners, insecticides and disinfectants. For compressed gas' aerosol formats, there is no flash vaporization of propellant so that pumping liquid from a metering chamber and atomization to form a spray must be achieved entirely by designing some means of using the pumping action of the gas in the container to act upon the liquid in the metering chamber. The new design utilizes a loosely fitting spherical piston element and a simple arrangement of a concentric housing and a moveable valve stem, such that liquid flow paths between the different elements are automatically closed and opened in the correct time sequence when the valve stem is depressed and released. Spraying data show excellent repeatability of liquid sprayed per pulse throughout the lifetime of device and drop sizes that are acceptable for devices such as air-fresheners and nasal sprays. The valve has only one additional component compared with liquefied gas metered valves and can be straightforwardly injection moulded. As will be explained, previous attempts failed due to expense, complexity and unreliability.
引用
收藏
页码:1557 / 1568
页数:12
相关论文
共 50 条
  • [21] Modeling of aerosol deposition with interface devices
    Finlay, W. H.
    Martin, A. R.
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2007, 20 : S19 - S26
  • [22] Practical problems with aerosol therapy in COPD
    Rau, JL
    RESPIRATORY CARE, 2006, 51 (02) : 158 - 172
  • [23] Aerosol Plumes of Inhalers Used in COPD
    Herbert Wachtel
    Rachel Emerson-Stadler
    Peter Langguth
    Jens M. Hohlfeld
    Jill Ohar
    Pulmonary Therapy, 2024, 10 : 109 - 122
  • [24] In vitro aerosol characterization of Staccato® Loxapine
    Dinh, Khe
    Myers, Dan J.
    Glazer, Marc
    Shmidt, Tamara
    Devereaux, Caitlin
    Simis, Kathleen
    Noymer, Peter D.
    He, Min
    Choosakul, Corinna
    Chen, Qiang
    Cassella, James V.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2011, 403 (1-2) : 101 - 108
  • [25] Pharmaceutical, Clinical, and Regulatory Challenges of Reformulating Pressurized Metered-Dose Inhalers to Reduce Their Environmental Impact
    Roche, Nicolas
    Usmani, Omar
    Franzini, Laura
    Labadini, Lorenza
    Mathews, Kusum S.
    Panigone, Sara
    van Boven, Job F. M.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2025, 38 (01) : 26 - 36
  • [26] A Valved Holding Chamber Does Not Decrease the Bronchodilator Activity of Budesonide-Formoterol Combination Metered Dose Inhaler
    Mansfield, Lyndon E.
    Maynes, Ruby
    JOURNAL OF ASTHMA, 2013, 50 (01) : 71 - 74
  • [27] Handling of inhaler devices in actual pulmonary practice: Metered-dose inhaler versus dry powder inhalers
    Khassawneh, Basheer Y.
    Al-Ali, Musa K.
    Alzoubi, Karem H.
    Batarseh, Morad Z.
    Al-Safi, Saafan A.
    Sharara, Abdelmonem M.
    Alnasr, Hatem M.
    RESPIRATORY CARE, 2008, 53 (03) : 324 - 328
  • [28] The effect of exhalation before the inhalation of dry powder aerosol drugs on the breathing parameters, emitted doses and aerosol size distributions
    Farkas, Arpad
    Tomisa, Gabor
    Kugler, Szilvia
    Nagy, Attila
    Vasko, Attila
    Kis, Erika
    Szenasi, Georgina
    Galffy, Gabriella
    Horvath, Alpar
    INTERNATIONAL JOURNAL OF PHARMACEUTICS-X, 2023, 5
  • [29] Characterization of Medication Velocity and Size Distribution from Pressurized Metered-Dose Inhalers by Phase Doppler Anemometry
    Alatrash, Abubaker
    Matida, Edgar
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2016, 29 (06) : 501 - 513
  • [30] Comparison of systemic pharmacodynamic effects of two combination pressurized metered dose inhalers that deliver salmeterol and fluticasone propionate
    Harrison, Lester I.
    Sessions, Victoria
    Wiggenhorn, Christopher J.
    Chalmers, David
    Leung, Pui
    Efthimiou, John
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2017, 83 (11) : 2377 - 2385