Simultaneous determination of Cr(III)-EDTA and Cr(VI) by ion interaction chromatography using a C18 column

被引:42
作者
Threeprom, H [1 ]
Purachaka, S [1 ]
Potipan, L [1 ]
机构
[1] Mahasarakham Univ, Fac Sci, Dept Chem, Maha Sarakham 44150, Thailand
关键词
ion interaction chromatography; Cr(III)-EDTA; Cr(VI);
D O I
10.1016/j.chroma.2004.09.053
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The simultaneous determination of Cr(III) and Cr(VI) by ion interaction chromatography has been investigated. The mobile phase consisted of a 5 mM octylammonium orthophosphate at pH 4.0 with 35% (v/v) MeOH. The Nucleosil- 100, C-18 (5 mu m, 250 x 4.6 mm) was used as the separating column and the component was detected at 200 nm. The separation of Cr(III) and Cr(VI) was based on anionic interaction. Since the Cr(III) did not exist as an anionic form like the Cr(VI) (Cr2O72-) presented at the optimum condition, Cr(III) was firstly reacted with EDTA (1:40 mole ratio) to form the anionic complex prior to injecting into the chromatographic system. The characteristics of the method for separation of Cr(III)-EDTA and Cr(VI) were satisfactory. The wide linear range (0.3-50.0 mg l(-1)) was achieved. The repeatabilities (%R.S.D.) calculated from peak areas were 0.49% and 0.14%, detection limit (signal to noise ratio of 3) of 0.02 mg l(-1) and 0.3 mg l(-1) were obtained and the average of percent recoveries were found to be 98.5% and 99.6% for Cr(III) and Cr(VI), respectively. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:291 / 295
页数:5
相关论文
共 28 条
[1]   Speciation of chromium using reversed phase-high performance liquid chromatography coupled to different spectrometric detection methods [J].
Andrle, CM ;
Jakubowski, N ;
Broekaert, JAC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (02) :189-200
[2]   CHROMIUM SPECIATION BY ANION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH BOTH INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPIC AND INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC DETECTION [J].
BYRDY, FA ;
OLSON, LK ;
VELA, NP ;
CARUSO, JA .
JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (02) :311-320
[3]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF NITRILOTRIACETIC ACID, ETHYLENEDIAMINETETRAACETIC ACID, AND RELATED AMINOPOLYCARBOXYLIC ACIDS USING AN AMPEROMETRIC DETECTOR [J].
DAI, J ;
HELZ, GR .
ANALYTICAL CHEMISTRY, 1988, 60 (04) :301-305
[4]   SIMULTANEOUS DETERMINATION OF CHROMIUM(III) AND CHROMIUM(VI) IN AQUEOUS-SOLUTIONS BY ION CHROMATOGRAPHY AND CHEMILUMINESCENCE DETECTION [J].
GAMMELGAARD, B ;
JONS, O ;
NIELSEN, B .
ANALYST, 1992, 117 (03) :637-640
[5]   On-line chromatographic separation and determination of chromium(III) and chromium(VI) with preconcentration of the chromium(III) using potassium hydrogen phthalate, in various samples by flame atomic absorption spectrometry [J].
Gaspar, A ;
Posta, J ;
Toth, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (11) :1067-1074
[6]   Separation and determination of inorganic anions by reversed-phase high-performance liquid chromatography [J].
Gennaro, MC ;
Angelino, S .
JOURNAL OF CHROMATOGRAPHY A, 1997, 789 (1-2) :181-194
[7]  
GJERDE DT, 1991, TRACE METAL ANAL SPE, P213
[8]   DETERMINATION OF INORGANIC ANIONS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HADDAD, PR ;
HECKENBERG, AL .
JOURNAL OF CHROMATOGRAPHY, 1984, 300 (03) :357-394
[9]   ANION CHROMATOGRAPHY USING OCTADECYLSILANE REVERSED-PHASE COLUMNS COATED WITH CETYLTRIMETHYLAMMONIUM AND ITS APPLICATION TO NITRITE AND NITRATE IN SEAWATER [J].
ITO, K ;
ARIYOSHI, Y ;
TANABIKI, F ;
SUNAHARA, H .
ANALYTICAL CHEMISTRY, 1991, 63 (03) :273-276
[10]   DETERMINATION OF METAL-IONS AS EDTA COMPLEXES BY REVERSED-PHASE ION-PAIR LIQUID-CHROMATOGRAPHY [J].
JEN, JF ;
CHEN, CS .
ANALYTICA CHIMICA ACTA, 1992, 270 (01) :55-61