Modified TID controller for load frequency control of a two-area interconnected diverse-unit power system

被引:100
|
作者
Ahmed, Mohamed [1 ]
Magdy, Gaber [2 ]
Khamies, Mohamed [3 ]
Kamel, Salah [3 ]
机构
[1] Sohag Univ, Fac Engn, Dept Elect Engn, Sohag 82524, Egypt
[2] Aswan Univ, Fac Energy Engn, Dept Elect Engn, Aswan 81528, Egypt
[3] Aswan Univ, Fac Engn, Elect Engn Dept, Aswan 81542, Egypt
关键词
Load frequency control (LFC); Tilted integral derivative (TID); Integral derivative-tilted (ID-T); Archimedes optimization algorithm (AOA); Renewable energy sources (RESs); AUTOMATIC-GENERATION CONTROL; DERIVATIVE CONTROLLER; STABILITY; DESIGN; AGC; STRATEGY; TCSC;
D O I
10.1016/j.ijepes.2021.107528
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, a modified structure of the tilted integral derivative (TID) controller, i.e. an integral derivativetilted (ID-T) controller, is developed for the load frequency control issue of a multi-area interconnected multisource power system. Moreover, a new optimization algorithm known as Archimedes optimization algorithm (AOA) is used to fine-tune the proposed ID-T controller parameters. The performance of the proposed ID-T controller based on AOA is evaluated through a two-area interconnected power system, each area containing various conventional generation units (i.e., thermal, gas, and hydraulic power plants) and renewables (wind and solar power). Furthermore, system nonlinearities (i.e., generation rate constraints, governor deadband, and communication time delays), system uncertainties, and load/renewables fluctuations are considered in designing the proposed controller. The effectiveness of the proposed ID-T controller based on AOA is verified by comparing its performance with other control techniques in the literature (i.e. integral controller, proportional integral derivative (PID) controller, fractional-order PID controller, TID controller, and I-TD controller). The AOA's optimization superiority has also been verified against a variety of other sophisticated optimization methods, including particle swarm optimization and whale optimization algorithm. The simulation results exhibit that the proposed ID-T controller based on the AOA presents a great improvement in the system frequency stability under several contingencies of different load perturbations, system uncertainties, physical constraints, communication time delays, high renewables penetration.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Impact of storage device on Load frequency control of a two-area renewable penetrated power system
    Jood, Pankaj
    Aggarwal, S. K.
    Chopra, Vikram
    2018 IEEE 8TH POWER INDIA INTERNATIONAL CONFERENCE (PIICON), 2018,
  • [42] Load Frequency Control Design of Two Area Interconnected Power System Using GWO
    Elkasem, Ahmed. H. A.
    Kamel, Salah
    Korashy, Ahmed
    Nasrat, Loai
    2019 IEEE CONFERENCE ON POWER ELECTRONICS AND RENEWABLE ENERGY (IEEE CPERE), 2019, : 278 - 283
  • [43] Decentralized load frequency controller for a multi-area interconnected power system
    Alrifai, Muthana T.
    Hassan, Mohamed F.
    Zribi, Mohamed
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2011, 33 (02) : 198 - 209
  • [44] Fuzzy-PID Controller Optimized TLBO Algorithm on Automatic Generation Control of a two-area Interconnected Power System
    Nayak, Jyoti Ranjan
    Pati, Tridipta Kumar
    Sahu, Binod Kumar
    Kar, Sanjeeb Kumar
    2015 INTERNATIONAL CONFERENCED ON CIRCUITS, POWER AND COMPUTING TECHNOLOGIES (ICCPCT-2015), 2015,
  • [45] Discrete data load frequency control of two-area power system with multi-source power generation
    Centre for Energy Studies, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110 016, India
    Int. Energy J., 2008, 2 (145-154):
  • [46] Discrete Data Load Frequency Control of Two-Area Power System with Multi-Source Power Generation
    Ramakrishna, K. S. S.
    Bhatti, T. S.
    INTERNATIONAL ENERGY JOURNAL, 2008, 9 (02): : 145 - 154
  • [47] LFOPI controller: a fractional order PI controller based load frequency control in two area multi-source interconnected power system
    Sharma, Deepesh
    Yadav, Naresh Kumar
    DATA TECHNOLOGIES AND APPLICATIONS, 2020, 54 (03) : 323 - 342
  • [48] A novel modified whale optimization algorithm for load frequency controller design of a two-area power system composing of PV grid and thermal generator
    Khadanga, Rajendra Kumar
    Kumar, Amit
    Panda, Sidhartha
    NEURAL COMPUTING & APPLICATIONS, 2020, 32 (12): : 8205 - 8216
  • [49] A novel modified whale optimization algorithm for load frequency controller design of a two-area power system composing of PV grid and thermal generator
    Khadanga, Rajendra Kumar
    Kumar, Amit
    Panda, Sidhartha
    Neural Computing and Applications, 2020, 32 (12) : 8205 - 8216
  • [50] Design of Fractional Order PID Controller for Load Frequency Control in Perturbed Two Area Interconnected System
    Lamba, Ruchika
    Singla, Sunil Kumar
    Sondhi, Swati
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2019, 47 (11-12) : 998 - 1011