Strategies for Radiation-dose Reduction and Image-quality Optimization in Multidetector Computed Tomographic Coronary Angiography

被引:11
作者
Torres, Felipe S. [1 ,2 ]
Crean, Andrew M. [1 ,2 ]
Nguyen, Elsie T. [1 ,2 ]
Paul, Narinder [1 ,2 ]
机构
[1] Univ Toronto, Toronto Gen Hosp, Div Cardiothorac Imaging, Dept Med Imaging, 585 Univ Ave, Toronto, ON M5G 2N2, Canada
[2] Toronto Gen Hosp, Univ Hlth Network, Toronto, ON M5G 2N2, Canada
来源
CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES | 2010年 / 61卷 / 05期
关键词
Multidetector computed tomography; Cardiac computed tomography; Radiation dose; Dose reduction; Image quality; DUAL-SOURCE CT; NORTH-AMERICAN-SOCIETY; COLLEGE-OF-RADIOLOGY; 16-DETECTOR ROW CT; CARDIAC CT; ARTERY CALCIUM; BETA-BLOCKERS; CANCER-RISK; TEST-BOLUS; IN-VITRO;
D O I
10.1016/j.carj.2009.11.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The technological evolution of computed tomography (CT) in the last decade has placed CT coronary angiography (CTCA) in the spotlight of imaging modalities available to evaluate patients with coronary artery disease. Widespread utilisation of CTCA has generated concern from the medical community regarding potential health issues related to the significant radiation exposure associated with this method, and several modifications of the CTCA technique have been proposed to reduce the radiation exposure without affecting the diagnostic image quality. This review will discuss a practical approach to performing CTCA to ensure that the radiation dose is minimized while maintaining diagnostic image quality.
引用
收藏
页码:271 / 279
页数:9
相关论文
共 55 条
[1]   Radiation dose of cardiac dual-source CT: The effect of tailoring the protocol to patient-specific parameters [J].
Alkadhi, Hatem ;
Stolzmann, Paul ;
Scheffel, Hans ;
Desbiolles, Lotus ;
Baumueller, Stephan ;
Plass, Andre ;
Genoni, Michele ;
Marincek, Borut ;
Leschka, Sebastian .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) :385-391
[2]   Scan and contrast administration principles of MDCT [J].
Bae, KT ;
Heiken, JP .
EUROPEAN RADIOLOGY, 2005, 15 :E46-E59
[3]   Test-bolus versus bolus-tracking techniques for CT angiographic timing [J].
Bae, KT .
RADIOLOGY, 2005, 236 (01) :369-370
[4]   Contrast enhancement in cardiovascular MDCT: Effect of body weight, height, body surface area, body mass index, and obesity [J].
Bae, Kyongtae T. ;
Seeck, Brian A. ;
Hildebolt, Charles F. ;
Tao, Cheng ;
Zhu, Fang ;
Kanematsu, Masayuki ;
Woodard, Pamela K. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (03) :777-784
[5]   Preview method for electron-beam CT scanning of the coronary arteries [J].
Bakhsheshi, H ;
Mao, SS ;
Budoff, MJ ;
Bin, L ;
Brundage, BH .
ACADEMIC RADIOLOGY, 2000, 7 (08) :620-626
[6]   Optimal contrast application for cardiac 4-detector-row computed tomography [J].
Becker, CR ;
Hong, C ;
Knez, A ;
Leber, A ;
Bruening, R ;
Schoepf, UJ ;
Reiser, MF .
INVESTIGATIVE RADIOLOGY, 2003, 38 (11) :690-694
[7]   Radiation Dose and Image Quality of Prospective Triggering With Dual-Source Cardiac Computed Tomography [J].
Blankstein, Ron ;
Shah, Amar ;
Pale, Rodrigo ;
Abbara, Suhny ;
Bezerra, Hiram ;
Bolen, Michael ;
Mamuya, Wilfred S. ;
Hoffmann, Udo ;
Brady, Thomas J. ;
Cury, Ricardo C. .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (08) :1168-1173
[8]   Assessment of coronary artery disease by cardiac computed tomography - A scientific statement from the American Heart Association committee on cardiovascular imaging and intervention, council on cardiovascular radiology and intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology [J].
Budoff, Matthew J. ;
Achenbach, Stephan ;
Blumenthal, Roger S. ;
Carr, J. Jeffrey ;
Goldin, Jonathan G. ;
Greenland, Philip ;
Guerci, Alan D. ;
Lima, Joao A. C. ;
Rader, Daniel J. ;
Rubin, Geoffrey D. ;
Shaw, Leslee J. ;
Wiegers, Susan E. .
CIRCULATION, 2006, 114 (16) :1761-1791
[9]   Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique [J].
Cademartiri, F ;
Nieman, K ;
van der Lugt, A ;
Raaijmakers, RH ;
Mollet, N ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2004, 233 (03) :817-823
[10]   Intravenous contrast material administration at helical 16-detector row CT coronary angiography: Effect of iodine concentration on vascular attenuation [J].
Cademartiri, F ;
Mollet, NR ;
van der Lugt, A ;
McFadden, EP ;
Stijnen, T ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2005, 236 (02) :661-665