Analytical applications of glassy carbon electrodes modified with multi-wall carbon nanotubes dispersed in polyethylenimine as detectors in flow systems

被引:65
作者
Sanchez Arribas, Alberto [1 ]
Bermejo, Esperanza
Chicharro, Manuel
Zapardiel, Antonio
Luque, Guillermina L.
Ferreyra, Nancy E.
Rivas, Gustavo A.
机构
[1] Univ Autonoma Madrid, Fac Ciencias, Dept Quim Analit & Anal Instrumental, E-28049 Madrid, Spain
[2] Univ Nacl Educ Distancia, Fac Ciencias, Dept Ciencias Analit, E-28040 Madrid, Spain
[3] Univ Nacl Cordoba, Fac Ciencias Quim, Dept Fisicoquim, INFIQC, RA-5000 Cordoba, Argentina
关键词
carbon nanotubes; polyethylenimine; glassy carbon; neurotransmitters; phenolic compounds; herbicides; catecholamines; flow injection; capillary electrophoresis; PYROLYTIC-GRAPHITE ELECTRODES; PASTE ELECTRODES; ELECTROCHEMICAL SENSORS; NADH DETECTION; BIOSENSORS; CHITOSAN; NANOPARTICLES; SITES;
D O I
10.1016/j.aca.2007.06.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports the advantages of using glassy carbon electrodes (GCEs) modified with multi-wall carbon nanotubes (CNT) dispersed in polyethylenimine (PEI) as detectors in flow injection and capillary electrophoresis. The presence of the dispersion of CNT in PEI at the electrode surface allows the highly sensitive and reproducible determination of hydrogen peroxide, different neurotransmitters (dopamine (D) and its metabolite dopac, epinephrine (E), norepinephrine (NE)), phenolic compounds (phenol (P), 3-chlorophenol (3-CP) and 2,3-dichlorophenol (2,3CP)) and herbicides (amitrol). Sensitivities enhancements of 150 and 140 folds compared to GCE were observed for hydrogen peroxide and amitrol, respectively. One of the most remarkable properties of the resulting electrode is the antifouling effect of the CNT/PEI layer. No passivation was observed either for successive additions (30) or continuous flow (for 30 min) of the compounds under investigation, even dopac or phenol. A critical comparison of the amperometric and voltammetric signal of these different analytes at bare- and PEI-modified glassy carbon electrodes and pyrolytic graphite electrodes is also included, demonstrating that the superior performance of CNT is mainly due to their unique electrochemical properties. Glassy carbon electrodes modified with CNT-PEI dispersion also show an excellent performance as amperometric detector in the electrophoretic separation of phenolic compounds and neurotransmitters making possible highly sensitive and reproducible determinations. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:183 / 194
页数:12
相关论文
共 37 条
  • [31] Biosensing in high-performance chemical separations
    Trojanowicz, M
    Szewczynska, M
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (02) : 92 - 106
  • [32] Present and future applications of carbon nanotubes to analytical science
    Valcárcel, M
    Simonet, BM
    Cárdenas, S
    Suárez, B
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (08) : 1783 - 1790
  • [33] Polymers containing fullerene or carbon nanotube structures
    Wang, CC
    Guo, ZX
    Fu, SK
    Wu, W
    Zhu, DB
    [J]. PROGRESS IN POLYMER SCIENCE, 2004, 29 (11) : 1079 - 1141
  • [34] Nanomaterial-based electrochemical biosensors
    Wang, J
    [J]. ANALYST, 2005, 130 (04) : 421 - 426
  • [35] Solubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors
    Wang, J
    Musameh, M
    Lin, YH
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (09) : 2408 - 2409
  • [36] Carbon nanotube-chitosan system for electrochemical sensing based on dehydrogenase enzymes
    Zhang, MG
    Smith, A
    Gorski, W
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (17) : 5045 - 5050
  • [37] 2003, PRODUCTOS VEGETALES, P39265