Hepatic metastases: use of diffusion-weighted echo-planar imaging

被引:29
|
作者
Bruegel, Melanie [1 ]
Rummeny, Ernst J. [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Radiol, D-81675 Munich, Germany
来源
ABDOMINAL IMAGING | 2010年 / 35卷 / 04期
关键词
Diffusion Magnetic Resonance Imaging; Echo-planar imaging; Liver neoplasms; Liver metastases; Detection; INTRAVOXEL INCOHERENT MOTION; LIVER LESION DETECTION; ABDOMINAL ORGANS; MRI; ECHOPLANAR; SEQUENCES; COEFFICIENTS; ONCOLOGY; GRADIENT; ABDOMEN;
D O I
10.1007/s00261-009-9541-8
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Diffusion-weighted MR imaging is increasingly applied to detect and characterize focal hepatic lesions. In this update article, technical aspects regarding diffusion-weighted echo-planar imaging (DW-EPI) of the liver will be addressed, and concepts for image interpretation will be provided. The value of DW-EPI for the detection of hepatic metastases is illustrated on the basis of a review of the literature and our personal experience. In this respect, special emphasis is given to the comparison of DW-EPI with well-established MR imaging techniques such as T2-weighted and contrast-enhanced MR imaging, and advantages and limitations of DW-EPI will be described. Based on the review, it is concluded that DW-EPI is more sensitive than T2-weighted MR imaging and at least as accurate as superparamagnetic iron oxide-enhanced or gadolinium-enhanced MR imaging for the detection of hepatic metastases. Although difficulties occasionally arise in further characterizing small lesions detected with DW-EPI, substantial improvements in the preoperative evaluation of liver metastases in candidates for hepatic resection may be expected.
引用
收藏
页码:454 / 461
页数:8
相关论文
共 50 条
  • [11] Improvement of renal diffusion-weighted magnetic resonance imaging with readout-segmented echo-planar imaging at 3 T
    Friedli, Iris
    Crowe, Lindsey A.
    Viallon, Magalie
    Porter, David A.
    Martin, Pierre-Yves
    de Seigneux, Sophie
    Vallee, Jean-Paul
    MAGNETIC RESONANCE IMAGING, 2015, 33 (06) : 701 - 708
  • [12] Readout-segmented Echo-planar Imaging for Diffusion-weighted Imaging in the Pelvis at 3T-A Feasibility Study
    Thian, Yee Liang
    Xie, Wanying
    Porter, David A.
    Ang, Bertrand Weileng
    ACADEMIC RADIOLOGY, 2014, 21 (04) : 531 - 537
  • [13] Comparison of the Image Quality of Turbo Spin Echo and Echo-Planar Diffusion-Weighted Imaging of the Head and Neck Region
    Sam, Ajina
    Misbah, Iffath
    Ram, Jasvant
    Raja, Sam
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [14] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [15] Hepatic epithelioid hemangioendothelioma: findings at CT and MRI including preliminary observations at diffusion-weighted echo-planar imaging
    Melanie Bruegel
    Daniela Muenzel
    Simone Waldt
    Katja Specht
    Ernst J. Rummeny
    Abdominal Imaging, 2011, 36 : 415 - 424
  • [16] Hepatic epithelioid hemangioendothelioma: findings at CT and MRI including preliminary observations at diffusion-weighted echo-planar imaging
    Bruegel, Melanie
    Muenzel, Daniela
    Waldt, Simone
    Specht, Katja
    Rummeny, Ernst J.
    ABDOMINAL IMAGING, 2011, 36 (04): : 415 - 424
  • [17] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    An, He
    Ma, Xiaodong
    Pan, Ziyi
    Guo, Hua
    Lee, Elaine Yuen Phin
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 1876 - 1884
  • [18] Correction for eddy current induced Bo shifts in diffusion-weighted echo-planar imaging
    Calamante, F
    Porter, DA
    Gadian, DG
    Connelly, A
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (01) : 95 - 102
  • [19] Diffusion-weighted imaging of the brain: comparison of stimulated- and spin-echo echo-planar sequences
    Heiland, S
    Dietrich, O
    Sartor, K
    NEURORADIOLOGY, 2001, 43 (06) : 442 - 447
  • [20] Diffusion-weighted imaging of the brain: comparison of stimulated- and spin-echo echo-planar sequences
    S. Heiland
    O. Dietrich
    K. Sartor
    Neuroradiology, 2001, 43 : 442 - 447