Inherent Correlation Between the Breakdown Strength and the Surface Flashover Performance of Epoxy Resin in N2 Atmosphere

被引:2
作者
Xu, Haoming [1 ]
Liu, Wenfeng [1 ]
Li, Zhen [1 ]
Aslam, Farooq [1 ]
Li, Shengtao [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian, Peoples R China
来源
PROCEEDINGS OF THE 2020 3RD IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD 2020) | 2020年
关键词
INSULATORS;
D O I
10.1109/ICD46958.2020.9341968
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Surface flashover and breakdown are two typical failures of insulations, which inhibit the stability and downsizing of electrical apparatus. The two phenomena were traditional considered be affected by different factors. However, in the present study, the inherent correlation between surface flashover and gas breakdown strength was revealed. Experimentally epoxy resin composites with a thickness of 1 mm and diameter of 50 mm were prepared. Surface flashover voltages were measured for DC voltage in different pressure and temperature. Gas breakdown voltages were tested in a same condition. With temperature decreases or pressure increases, both gas breakdown voltage and surface flashover voltage increase. However, the growth rate is different for the two voltages. Gas breakdown voltage increases faster than surface flashover voltage. The ratio of flashover voltage to gas breakdown voltage decrease with gas pressure increase. This work investigates the relationship between surface flashover and gas breakdown by considering gas adsorption. It was found that sample gas adsorption capacity can affect the surface flashover voltage, but a saturation point exists. When the adsorbed gas molecules of samples reach saturation, the effect of adsorption on surface flashover performance is less than the effect of pressure on gas breakdown voltage.
引用
收藏
页码:794 / 797
页数:4
相关论文
共 12 条
[1]  
Chayawat C., 2019, WATER AIR SOIL POLL, V45, P50, DOI [DOI 10.1007/s11270-007-9372-6, DOI 10.1016/J.AMJMS.2021.03.001,00089-6]
[2]   REVIEW OF HIGH-VOLTAGE GAS-BREAKDOWN AND INSULATORS IN COMPRESSED GAS [J].
COOKSON, AH .
IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1981, 128 (04) :303-312
[3]   Temperature-Dependent Surface Charge and Flashover Behaviors of Oil-Paper Insulation Under Impulse With Superimposed DC Voltage [J].
Du, Boxue ;
Chang, Rui ;
Jiang, Jinpeng ;
Li, Jin .
IEEE ACCESS, 2018, 6 :63087-63093
[4]   High-power microwave surface flashover of a gas-dielectric interface at 90-760 torr [J].
Edmiston, Gregory ;
Krile, John ;
Neuber, Andreas ;
Dickens, James ;
Krompholz, Hermann .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2006, 34 (05) :1782-1788
[5]   Surface flashover performance of epoxy resin microcomposites improved by electron beam irradiation [J].
Huang, Yin ;
Min, Daomin ;
Li, Shengtao ;
Li, Zhen ;
Xie, Dongri ;
Wang, Xuan ;
Lin, Shengjun .
APPLIED SURFACE SCIENCE, 2017, 406 :39-45
[6]   Understanding Surface Charge Accumulation and Surface Flashover on Spacers in Compressed Gas Insulation [J].
Li, Chuanyang ;
Lin, Chuanjie ;
Zhang, Bo ;
Li, Qi ;
Liu, Weidong ;
Hu, Jun ;
He, Jinliang .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (04) :1152-1166
[7]   Unraveling the "U-Shaped" Dependence of Surface Flashover Performance on the Surface Trap Level [J].
Li, Shengtao ;
Li, Zhen ;
Huang, Yin ;
Xu, Haoming ;
Aslam, Farooq ;
Min, Daomin ;
Wang, Weiwang .
IEEE ACCESS, 2019, 7 :180923-180934
[8]   Synergic effect of adsorbed gas and charging on surface flashover [J].
Li, Shengtao ;
Huang, Yin ;
Min, Daomin ;
Qu, Guanghao ;
Niu, Huan ;
Li, Zhen ;
Wang, Weiwang ;
Li, Jianying ;
Liu, Wenfeng .
SCIENTIFIC REPORTS, 2019, 9 (1)
[9]   Flashover of Insulators in Vacuum: The Last Twenty Years [J].
Miller, H. Craig .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (06) :3641-3657
[10]   SURFACE FLASHOVER OF INSULATORS [J].
MILLER, HC .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1989, 24 (05) :765-786