Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study

被引:232
作者
Leipsic, Jonathon [1 ,2 ,7 ]
LaBounty, Troy M. [3 ]
Heilbron, Brett [2 ,7 ]
Min, James K. [3 ,4 ]
Mancini, G. B. John [5 ]
Lin, Fay Y. [3 ]
Taylor, Carolyn [2 ,7 ]
Dunning, Allison [3 ]
Earls, James P. [6 ]
机构
[1] St Pauls Hosp, Dept Med Imaging, Vancouver, BC V6Y 126, Canada
[2] Univ British Columbia, Dept Med, Div Cardiol, Vancouver, BC, Canada
[3] New York Presbyterian Hosp, Weill Cornell Med Coll, Div Cardiol, Dept Med, New York, NY USA
[4] New York Presbyterian Hosp, Weill Cornell Med Coll, Dept Radiol, New York, NY USA
[5] Univ British Columbia, Dept Med, Div Cardiol, Vancouver, BC, Canada
[6] Fairfax Radiol Consultants, Fairfax, VA USA
[7] Univ British Columbia, Dept Radiol, Div Cardiol, Vancouver, BC, Canada
关键词
adaptive statistical iterative reconstruction; coronary CT angiography; iterative reconstruction; radiation dose; CARDIAC COMPUTED-TOMOGRAPHY; IMPROVED IMAGE QUALITY; HELICAL CT; RADIOLOGY; ALGORITHM; COMMITTEE; EXPOSURE; HEART;
D O I
10.2214/AJR.10.4288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to assess the impact of Adaptive Statistical Iterative Reconstruction (ASIR) on radiation dose and study quality for coronary CT angiography (CTA). SUBJECTS AND METHODS. We prospectively evaluated 574 consecutive patients undergoing coronary CTA at three centers. Comparisons were performed between consecutive groups initially using filtered back projection (FBP) (n = 331) and subsequently ASIR (n = 243) with regard to patient and scan characteristics, radiation dose, and diagnostic study quality. RESULTS. There was no difference between groups in the use of prospective gating, tube voltage, or scan length. The examinations performed using ASIR had a lower median tube current than those obtained using FBP (median [interquartile range], 450 mA [350-600] vs 650 mA [531-750], respectively; p < 0.001). There was a 44% reduction in the median radiation dose between the FBP and ASIR cohorts (4.1 mSv [2.3-5.2] vs 2.3 mSv [1.9-3.5]; p < 0.001). After adjustment for scan settings, ASIR was associated with a 27% reduction in radiation dose compared with FBP (95% CI, 21-32%; p < 0.001). Despite the reduced current, ASIR was not associated with a difference in adjusted signal, noise, or signal-to-noise ratio (p = not significant). No differences existed between FBP and ASIR for interpretability per coronary artery (98.5% vs 99.3%, respectively; p = 0.12) or per patient (96.1% vs 97.1%, p = 0.65). CONCLUSION. ASIR enabled reduced tube current and lower radiation dose in comparison with FBP, with preserved signal, noise, and study interpretability, in a large multicenter cohort. ASIR represents a new technique to reduce radiation dose in coronary CTA studies.
引用
收藏
页码:655 / 660
页数:6
相关论文
共 50 条
  • [41] MDCT Arthrography of the Hip: Value of the Adaptive Statistical Iterative Reconstruction Technique and Potential for Radiation Dose Reduction
    Tobalem, Frank
    Dugert, Eric
    Verdun, Francis R.
    Dunet, Vincent
    Ott, Julien G.
    Rudiger, Hannes A.
    Cherix, Stephane
    Meuli, Reto
    Becce, Fabio
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (06) : W665 - W673
  • [42] Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection
    Moscariello, Antonio
    Takx, Richard A. P.
    Schoepf, U. Joseph
    Renker, Matthias
    Zwerner, Peter L.
    O'Brien, Terrence X.
    Allmendinger, Thomas
    Vogt, Sebastian
    Schmidt, Bernhard
    Savino, Giancarlo
    Fink, Christian
    Bonomo, Lorenzo
    Henzler, Thomas
    EUROPEAN RADIOLOGY, 2011, 21 (10) : 2130 - 2138
  • [43] Radiation Dose Reduction With Chest Computed Tomography Using Adaptive Statistical Iterative Reconstruction Technique: Initial Experience
    Prakash, Priyanka
    Kalra, Mannudeep K.
    Digumarthy, Subba R.
    Hsieh, Jiang
    Pien, Homer
    Singh, Sarabjeet
    Gilman, Matthew D.
    Shepard, Jo-Anne O.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (01) : 40 - 45
  • [44] Minimizing the radiation dose in coronary CT angiography using prospective ECG-triggering, low tube voltage and iterative reconstruction technologies
    Saglam, Muzaffer
    Ozturk, Ersin
    Kara, Kemal
    JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (01) : 46 - 47
  • [45] Minimizing the radiation dose in coronary CT angiography using prospective ECG-triggering, low tube voltage and iterative reconstruction technologies
    Muzaffer Saglam
    Ersin Ozturk
    Kemal Kara
    Japanese Journal of Radiology, 2015, 33 : 46 - 47
  • [46] Radiation Dose Reduction in Coronary CT Angiography Time to Buckle Down
    Einstein, Andrew J.
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (08) : 897 - 899
  • [47] Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction
    Niesten, Joris M.
    van der Schaaf, Irene C.
    Riordan, Alan J.
    de Jong, Hugo W. A. M.
    Horsch, Alexander D.
    Eijspaart, Daniel
    Smit, Ewoud J.
    Mali, Willem P. T. M.
    Velthuis, Birgitta K.
    EUROPEAN RADIOLOGY, 2014, 24 (02) : 484 - 493
  • [48] Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction
    Joris M. Niesten
    Irene C. van der Schaaf
    Alan J. Riordan
    Hugo W. A. M. de Jong
    Alexander D. Horsch
    Daniel Eijspaart
    Ewoud J. Smit
    Willem P. T. M. Mali
    Birgitta K. Velthuis
    European Radiology, 2014, 24 : 484 - 493
  • [49] Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective
    Brady, S. L.
    Yee, B. S.
    Kaufman, R. A.
    MEDICAL PHYSICS, 2012, 39 (09) : 5520 - 5531
  • [50] A Systematic Review of Image Quality, Diagnostic Value and Radiation Dose of Coronary CT Angiography Using Iterative Reconstruction Compared to Filtered Back Projection in the Diagnosis of Coronary Artery Disease
    Al Shammakhi, Ahmed
    Sun, Zhonghua
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (01) : 96 - 102